{"title":"Control","description":null,"products":[{"product_id":"4-pole-contactor-40-amp-120-vac-coil","title":"4 Pole Contactor 40 Amp 120 VAC Coil","description":"\u003ch2\u003e4 Pole Contactor 40 Amp 120 VAC Coil\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCoil Voltage: 110\/120 VAC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eLoad Rating: 40 Amp Full Load (Inductive), 50 Amp (Resistive)\u003c\/li\u003e\n\u003cli\u003ePoles: 4-Pole, Normally Open (N.O.)\u003c\/li\u003e\n\u003cli\u003eMaximum Voltage: 600 VAC\u003c\/li\u003e\n\u003cli\u003eTerminals: Quick connect for load and coil\u003c\/li\u003e\n\u003cli\u003eEnclosure: Open-type with universal mounting base\u003c\/li\u003e\n\u003cli\u003eCertifications: UL Listed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirectly replaces contactors with equivalent specifications.\u003c\/li\u003e\n\u003cli\u003eExample cross-reference: Square D 8910DPA44V02\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for definite purpose applications including HVAC, air conditioning, refrigeration, heating, and lighting systems.\u003c\/li\u003e\n\u003cli\u003eSuitable for single-phase motor loads up to 3 HP at 115 VAC.\u003c\/li\u003e\n\u003cli\u003eInterchangeable with contactors from various manufacturers that match the electrical specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAudible chattering, humming, or buzzing from the contactor during operation.\u003c\/li\u003e\n\u003cli\u003eVisible signs of heat damage, melting, or arcing on the housing or terminals.\u003c\/li\u003e\n\u003cli\u003eContacts are visibly pitted, burned, or welded together.\u003c\/li\u003e\n\u003cli\u003eConnected equipment (e.g., compressor, fan motor) fails to start or shut off.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all power to the equipment before installation.\u003c\/li\u003e\n\u003cli\u003eVerify the control circuit voltage matches the 110\/120 VAC coil rating.\u003c\/li\u003e\n\u003cli\u003eEnsure all wire connections are clean and securely fastened to the terminals.\u003c\/li\u003e\n\u003cli\u003eMount the contactor on a stable, flat surface within the equipment enclosure.\u003c\/li\u003e\n\u003cli\u003eConfirm the amperage and voltage ratings meet or exceed the requirements of the original part.\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45213783392445,"sku":"AZ00204294","price":34.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00204294_1_b79defec-ef3a-47fa-8c91-7f1398bdaab1.jpg?v=1765276005"},{"product_id":"3-pole-40-amp-contactor-120-vac-coil-definite-purpose-contactor","title":"3 Pole 40 Amp Contactor 120V Coil DP Contactor HVAC Contactor - 42CF35AF Equivalent","description":"\u003ch2\u003e3 Pole 40 Amp Contactor 120V Coil DP Contactor HVAC Contactor - 42CF35AF Equivalent\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePoles: 3 Pole, Normally Open (NO)\u003c\/li\u003e\n\u003cli\u003eAmperage Rating: 40 Ampere (A) Full Load Amps (FLA)\u003c\/li\u003e\n\u003cli\u003eCoil Voltage: 110\/120 Volts AC (VAC)\u003c\/li\u003e\n\u003cli\u003eFrequency: 50\/60 Hertz (Hz)\u003c\/li\u003e\n\u003cli\u003eMaximum Voltage: 600 VAC\u003c\/li\u003e\n\u003cli\u003eContacts: Silver alloy composition\u003c\/li\u003e\n\u003cli\u003eTerminals: Lug style for secure connections\u003c\/li\u003e\n\u003cli\u003eHousing: Durable, high-impact plastic construction\u003c\/li\u003e\n\u003cli\u003eCertification: UL Listed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eServes as a universal replacement for definite purpose contactors with matching electrical specifications.\u003c\/li\u003e\n\u003cli\u003eSuitable for replacing 20A, 25A, 30A, 35A, and 40A 3-pole contactors where the application load does not exceed 40A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for commercial and residential applications.\u003c\/li\u003e\n\u003cli\u003eCommonly used in HVAC systems, including air conditioners and heat pumps.\u003c\/li\u003e\n\u003cli\u003eSuitable for refrigeration units, motor loads, and lighting control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVisible signs of physical damage, such as burnt contacts, pitting, or a melted housing.\u003c\/li\u003e\n\u003cli\u003eAudible buzzing, humming, or chattering from the contactor during operation.\u003c\/li\u003e\n\u003cli\u003eThe controlled equipment fails to start (contactor not closing) or will not shut off (contactor welded shut).\u003c\/li\u003e\n\u003cli\u003eIntermittent or unreliable operation of the system.\u003c\/li\u003e\n\u003cli\u003eThe coil is open or shorted, preventing the contactor from energizing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all power to the unit before beginning installation or service.\u003c\/li\u003e\n\u003cli\u003eVerify that the control circuit voltage matches the contactor's 120 VAC coil rating.\u003c\/li\u003e\n\u003cli\u003eEnsure all electrical connections are tightened securely to the lug terminals to prevent overheating.\u003c\/li\u003e\n\u003cli\u003eMount the contactor securely on a clean, flat surface.\u003c\/li\u003e\n\u003cli\u003eProfessional installation by a qualified technician is recommended.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45213783523517,"sku":"AZ00126340","price":21.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00126340_1_b95446ae-0889-45d6-ac11-fdaf71d74a13.jpg?v=1779870905"},{"product_id":"c130a-1-pole-contactor-30-amp-24vac-coil","title":"C130A 1 Pole Contactor 30 Amp 24VAC Coil","description":"\u003ch2\u003eC130A 1 Pole Contactor 30 Amp 24VAC Coil\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePoles: 1 Pole with Shunt\u003c\/li\u003e\n\u003cli\u003eCoil Voltage: 24VAC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eFull Load Amps (FLA): 30A\u003c\/li\u003e\n\u003cli\u003eResistive Amps: 40A\u003c\/li\u003e\n\u003cli\u003eLocked Rotor Amps (LRA):\n\u003cul\u003e\n\u003cli\u003e180A at 240VAC\u003c\/li\u003e\n\u003cli\u003e150A at 480VAC\u003c\/li\u003e\n\u003cli\u003e120A at 600VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eInsulation: Class B\u003c\/li\u003e\n\u003cli\u003eTerminals: Includes box lugs and spade terminals\u003c\/li\u003e\n\u003cli\u003eMounting: Standard foot mount base\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePackard: C130A, PC130A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eApplication: Definite purpose contactor for HVAC and electrical control systems.\u003c\/li\u003e\n\u003cli\u003eCommonly used in residential and light commercial air conditioning condensing units from 1.5 to 3.5 tons.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe connected system fails to start or shut off.\u003c\/li\u003e\n\u003cli\u003eVisible damage, such as pitting, burns, or melted housing on the contacts.\u003c\/li\u003e\n\u003cli\u003eLoud buzzing, humming, or chattering noise during operation.\u003c\/li\u003e\n\u003cli\u003eThe internal coil fails continuity testing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all electrical power to the unit before beginning installation.\u003c\/li\u003e\n\u003cli\u003eVerify the system control voltage matches the contactor's 24VAC coil rating.\u003c\/li\u003e\n\u003cli\u003eEnsure all wire connections are secure and tightened to manufacturer specifications to prevent overheating.\u003c\/li\u003e\n\u003cli\u003eMount the contactor securely on a flat surface to minimize vibration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45369796427965,"sku":"AZ00227285","price":18.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00227285_1_2d03cec3-ebda-4d29-a91e-33b82297c8a1.jpg?v=1762246395"},{"product_id":"2-pole-contactor-40-amp-120vac-coil","title":"2 Pole Contactor 40 Amp 120VAC Coil","description":"\u003ch2\u003e2 Pole Contactor 40 Amp 120VAC Coil\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePoles: 2\u003c\/li\u003e\n\u003cli\u003eRated Current: 40 Amp Full Load Amps (FLA)\u003c\/li\u003e\n\u003cli\u003eCoil Voltage: 110\/120VAC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eMaximum Voltage Rating: 600VAC\u003c\/li\u003e\n\u003cli\u003eTerminal Type: Box lugs and 1\/4 inch quick connect terminals\u003c\/li\u003e\n\u003cli\u003eMounting: Standard mounting base for universal fit\u003c\/li\u003e\n\u003cli\u003eConstruction: Heavy-duty enclosed housing with copper contacts\u003c\/li\u003e\n\u003cli\u003eCertifications: UL Certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSquare D: 8910DP42V02\u003c\/li\u003e\n\u003cli\u003eABB: DP40C2P-1\u003c\/li\u003e\n\u003cli\u003eElecDirect: TCDP402G6\u003c\/li\u003e\n\u003cli\u003eInterchangeable with other definite purpose contactors with matching electrical specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for use in HVAC, air conditioning units, refrigeration systems, heating, lighting, and motor control applications.\u003c\/li\u003e\n\u003cli\u003eFits as a universal replacement for most residential and commercial definite purpose contactor applications requiring a 2-pole, 40 Amp, 120VAC coil configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContactor makes a loud buzzing or humming noise.\u003c\/li\u003e\n\u003cli\u003eVisible signs of heat damage, melting, or burning on the housing or terminals.\u003c\/li\u003e\n\u003cli\u003eContacts are pitted, corroded, or welded together.\u003c\/li\u003e\n\u003cli\u003eThe controlled unit (e.g., compressor, fan motor) fails to start or will not turn off.\u003c\/li\u003e\n\u003cli\u003eCoil is open or shorted, preventing the contactor from energizing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all electrical power to the equipment before beginning installation.\u003c\/li\u003e\n\u003cli\u003eConfirm the voltage and amperage ratings of the new contactor match the system's requirements.\u003c\/li\u003e\n\u003cli\u003eTransfer wires from the old contactor to the new one, ensuring connections are clean and secure.\u003c\/li\u003e\n\u003cli\u003eMount the new contactor securely in the control panel.\u003c\/li\u003e\n\u003cli\u003eAfter installation, restore power and verify proper operation of the equipment.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45369796493501,"sku":"AZ00979627","price":20.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00979627_1_47f7ad7b-e35c-48c4-ba41-cafd3aa8b6c7.jpg?v=1762246394"},{"product_id":"2-pole-contactor-30-amp-120vac-coil","title":"2 Pole Contactor 30 Amp 120VAC Coil - Fits C230B, TJT30A120V2P, 17325, PC230A, H230A, 90-244","description":"\u003ch2\u003e2-Pole 30 Amp 120 Volt AC Contactor Relay\u003c\/h2\u003e\n\u003cp\u003eIntroducing our Heavy-Duty 2-Pole 30 Amp 120 Volt AC Contactor Relay, designed for reliable performance in various applications. This contactor relay is ideal for HVAC systems, refrigeration equipment, and more, ensuring efficient operation and durability.\u003c\/p\u003e\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Construction:\u003c\/strong\u003e Built to withstand demanding environments and ensure long-lasting performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30 Amp Rating:\u003c\/strong\u003e Capable of handling high current loads, making it suitable for a variety of applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e120 Volt AC Coil:\u003c\/strong\u003e Designed for easy integration with standard electrical systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Compatibility:\u003c\/strong\u003e Perfect for use with air conditioners, heat pumps, chillers, and refrigeration equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Operation:\u003c\/strong\u003e Ensures consistent performance and minimizes downtime in critical systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHVAC Systems\u003c\/li\u003e\n\u003cli\u003eAir Conditioners\u003c\/li\u003e\n\u003cli\u003eHeat Pumps\u003c\/li\u003e\n\u003cli\u003eChillers\u003c\/li\u003e\n\u003cli\u003eRefrigeration Equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUpgrade your system with our Heavy-Duty 2-Pole 30 Amp 120 Volt AC Contactor Relay and experience enhanced efficiency and reliability in your operations.\u003c\/p\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45369796657341,"sku":"AZ00218324","price":14.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00218324_1_e95c9789-8dcb-40f2-b2e1-f8faca8a44c6.jpg?v=1762246393"},{"product_id":"1-pole-contactor-32-amp-24vac-coil","title":"1 Pole Contactor 32 Amp 24VAC Coil","description":"\u003ch2\u003e1 Pole Contactor 32 Amp 24VAC Coil\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePoles: 1 (Single Pole)\u003c\/li\u003e\n\u003cli\u003eFull Load Amperage (FLA): 32A\u003c\/li\u003e\n\u003cli\u003eCoil Voltage: 24VAC, 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eApplication: Definite Purpose (DP) for HVAC and motor control\u003c\/li\u003e\n\u003cli\u003eContact Material: Copper alloy\u003c\/li\u003e\n\u003cli\u003eTerminals: Screw and quick-connect\u003c\/li\u003e\n\u003cli\u003eMounting: Panel mount with accessible mounting base\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e42-109499-15\u003c\/li\u003e\n\u003cli\u003eDILM32-01\u003c\/li\u003e\n\u003cli\u003eMC-32A-22-AC24\u003c\/li\u003e\n\u003cli\u003eDurastar 1P-32A-24V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for use in residential and commercial HVAC systems, including air conditioners and heat pumps.\u003c\/li\u003e\n\u003cli\u003eSuitable for controlling single-phase motors and other high-power loads such as refrigeration equipment, compressors, and resistive heating elements.\u003c\/li\u003e\n\u003cli\u003eDirect replacement for contactors with matching specifications: 1 pole, 32 Amp or lower rating, and a 24VAC control circuit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor condenser unit fails to start when the thermostat calls for cooling.\u003c\/li\u003e\n\u003cli\u003eA loud, continuous buzzing or humming noise from the outdoor unit.\u003c\/li\u003e\n\u003cli\u003eVisible damage to the contactor, including burnt terminals, pitting on contacts, or melted casing.\u003c\/li\u003e\n\u003cli\u003eThe contactor plunger is physically stuck in the engaged (pulled-in) or disengaged position.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all electrical power at the breaker panel and service disconnect before beginning installation.\u003c\/li\u003e\n\u003cli\u003eUse a multimeter to verify that no voltage is present in the unit.\u003c\/li\u003e\n\u003cli\u003ePhotograph or label all wires before disconnecting them from the original contactor to ensure correct placement on the new part.\u003c\/li\u003e\n\u003cli\u003eConfirm the new contactor's amperage rating meets or exceeds that of the original component.\u003c\/li\u003e\n\u003cli\u003eEnsure all electrical connections are tight and secure to prevent overheating and arcing.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45369796755645,"sku":"AZ00862343","price":15.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00862343_1_298145d6-622d-4e46-9776-678c5eae5109.jpg?v=1762246393"},{"product_id":"4-pole-contactor-40-amp-120-vac-coil-2pack","title":"4 Pole Contactor 40 Amp 120 VAC Coil - 2 Pack","description":"\u003ch2\u003e4 Pole Contactor 40 Amp 120 VAC Coil\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical Rating: 40 Amp resistive load capacity\u003c\/li\u003e\n\u003cli\u003eCoil Voltage: 120 VAC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eConfiguration: 4 Pole, with 2 Normally Open (NO) and 2 Normally Closed (NC) contacts\u003c\/li\u003e\n\u003cli\u003eConstruction: Features corrosion-resistant silver alloy contacts and a durable, compact housing\u003c\/li\u003e\n\u003cli\u003eDesign: Straight-through wiring and industry-standard mounting base for easy installation\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect replacement for definite purpose contactors with matching electrical specifications\u003c\/li\u003e\n\u003cli\u003eCommonly replaces models such as C25ENF440A and 42CF25AF\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for use in residential and commercial applications\u003c\/li\u003e\n\u003cli\u003eSuitable for HVAC systems, air conditioning units, heat pumps, and refrigeration systems\u003c\/li\u003e\n\u003cli\u003eAlso used for controlling motor loads and multi-circuit lighting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLoud buzzing, humming, or chattering noise during operation\u003c\/li\u003e\n\u003cli\u003eConnected equipment fails to start or runs continuously\u003c\/li\u003e\n\u003cli\u003eVisible signs of heat damage, melting, or arcing on the housing or contacts\u003c\/li\u003e\n\u003cli\u003ePitting or welding of the internal contacts, causing intermittent power\u003c\/li\u003e\n\u003cli\u003eThe coil is open or shorted, preventing the contactor from engaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all electrical power to the unit before servicing\u003c\/li\u003e\n\u003cli\u003eVerify the control circuit voltage matches the 120 VAC coil rating\u003c\/li\u003e\n\u003cli\u003eEnsure all wire terminals are tightened securely to prevent loose connections and overheating\u003c\/li\u003e\n\u003cli\u003eMount the contactor on a clean, flat surface in the designated location\u003c\/li\u003e\n\u003cli\u003eAfter installation, restore power and cycle the system to confirm proper operation\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45369796788413,"sku":"AZ00563041","price":70.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00563041_1_4301e7d4-fd0a-41fa-887d-8493f3efbb12.jpg?v=1762246392"},{"product_id":"2pcs-solid-state-relay-ssr25da-dc","title":"SSR-25DA DC to AC Solid State Relay - 2 Pack","description":"\u003ch2\u003eSSR-25DA Solid State Relay\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInput Control Voltage: 3-32V DC\u003c\/li\u003e\n\u003cli\u003eOutput Load Voltage: 24-380V AC\u003c\/li\u003e\n\u003cli\u003eMaximum Load Current: 25A\u003c\/li\u003e\n\u003cli\u003eDesign: Solid-state construction with no moving parts for high reliability and long service life.\u003c\/li\u003e\n\u003cli\u003eActuation: Zero-crossing turn-on circuit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSSR-25DA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for controlling single-phase AC loads in various applications.\u003c\/li\u003e\n\u003cli\u003eCommonly used in industrial automation, temperature control systems, PLC outputs, motor controls, and lighting equipment.\u003c\/li\u003e\n\u003cli\u003eRequires an appropriate heat sink for operation with loads greater than 10A to ensure proper heat dissipation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRelay fails to activate the load circuit when control voltage is applied.\u003c\/li\u003e\n\u003cli\u003eRelay remains activated and will not turn off the load circuit when control voltage is removed.\u003c\/li\u003e\n\u003cli\u003eIntermittent or unpredictable switching behavior.\u003c\/li\u003e\n\u003cli\u003eVisible signs of physical damage, such as cracking or burn marks on the housing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all power to the circuit before installation.\u003c\/li\u003e\n\u003cli\u003eVerify correct polarity (+\/-) for the DC input control terminals.\u003c\/li\u003e\n\u003cli\u003eApply a thin layer of thermal compound between the relay's metal base and the heat sink.\u003c\/li\u003e\n\u003cli\u003eMount the relay securely to a heat sink of adequate size for your load current.\u003c\/li\u003e\n\u003cli\u003eEnsure all wire connections are tight and secure to prevent overheating.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45369799049405,"sku":"AZ00847394","price":16.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00847394_1_2ed97db8-b10b-48cf-8668-75f261a47372.jpg?v=1762246372"},{"product_id":"me8108-momentary-roller-lever-arm-limit-switch-for-cnc-mill-laser-plasma","title":"ME-8108 Momentary Roller Lever Arm Limit Switch for CNC Mill Laser Plasma - 250VAC\/5A - 2 Pack","description":"\u003ch2\u003eME-8108 Momentary Roller Lever Arm Limit Switch\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel: ME-8108\u003c\/li\u003e\n\u003cli\u003eActuator Type: Rotary adjustable lever arm with roller\u003c\/li\u003e\n\u003cli\u003eAction Type: Momentary\u003c\/li\u003e\n\u003cli\u003eContact Configuration: 1NO, 1NC (DPST)\u003c\/li\u003e\n\u003cli\u003eVoltage\/Current Rating: AC 250V 5A\u003c\/li\u003e\n\u003cli\u003eHousing Material: Zinc alloy and reinforced plastic\u003c\/li\u003e\n\u003cli\u003eFeatures: Waterproof, oil-resistant, and dust-proof design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTZ-8108\u003c\/li\u003e\n\u003cli\u003eWLCA2\u003c\/li\u003e\n\u003cli\u003eWLCA2-2\u003c\/li\u003e\n\u003cli\u003eLSA1K2008E\u003c\/li\u003e\n\u003cli\u003eZCK-Y35H\u003c\/li\u003e\n\u003cli\u003eD4B-1112N\u003c\/li\u003e\n\u003cli\u003eWL-K12ME-QL\u003c\/li\u003e\n\u003cli\u003eVL-G12-1A25\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCNC milling machines\u003c\/li\u003e\n\u003cli\u003eCNC routers\u003c\/li\u003e\n\u003cli\u003eLaser cutting and engraving machines\u003c\/li\u003e\n\u003cli\u003ePlasma cutters\u003c\/li\u003e\n\u003cli\u003e3D printers\u003c\/li\u003e\n\u003cli\u003eAutomated control systems\u003c\/li\u003e\n\u003cli\u003eIndustrial machinery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSwitch fails to actuate or send a signal when the lever is depressed.\u003c\/li\u003e\n\u003cli\u003eSignal is intermittent or unreliable.\u003c\/li\u003e\n\u003cli\u003eThe switch does not reset to its original position after actuation.\u003c\/li\u003e\n\u003cli\u003eVisible physical damage to the roller, lever arm, or switch housing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAlways disconnect power to the machine before installation or maintenance.\u003c\/li\u003e\n\u003cli\u003eMount the switch securely to a stable, flat surface.\u003c\/li\u003e\n\u003cli\u003eAdjust the lever arm for precise contact and actuation by the moving component.\u003c\/li\u003e\n\u003cli\u003eEnsure correct wiring to the Normally Open (NO) or Normally Closed (NC) terminals based on your application's logic.\u003c\/li\u003e\n\u003cli\u003eProtect wires from abrasion, pinch points, and moving parts.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45369802260669,"sku":"AZ00210788","price":19.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00210788_1_4ae7fcc8-12cf-4c38-98a4-e57716df6eb7.jpg?v=1762246334"},{"product_id":"me8108-momentary-roller-lever-arm-limit-switch-5pack","title":"ME-8108 Momentary Roller Lever Arm Limit Switch for CNC Mill Laser Plasma - 250VAC\/5A - 5 Pack","description":"\u003ch2\u003eME-8108 Momentary Roller Lever Arm Limit Switch\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel: ME-8108\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eActuator Type: Adjustable rotary roller lever arm\u003c\/li\u003e\n\u003cli\u003eAction Type: Momentary\u003c\/li\u003e\n\u003cli\u003eContact Configuration: 1 NC + 1 NO (1 Normally Closed, 1 Normally Open)\u003c\/li\u003e\n\u003cli\u003eVoltage Rating: AC 250V\u003c\/li\u003e\n\u003cli\u003eCurrent Rating: 5A\u003c\/li\u003e\n\u003cli\u003eTerminal Type: Screw terminals\u003c\/li\u003e\n\u003cli\u003eConstruction: Double-circuit design with a built-in basic switch mechanism\u003c\/li\u003e\n\u003cli\u003eDimensions (L*W*H): 12.3 x 5 x 2.8 cm (4.8 x 2 x 1.1 inches)\u003c\/li\u003e\n\u003cli\u003eLever Arm Length: Approximately 10 cm (3.9 inches)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTZ-8108\u003c\/li\u003e\n\u003cli\u003eWLCA2\u003c\/li\u003e\n\u003cli\u003eWLCA2-2\u003c\/li\u003e\n\u003cli\u003eLSA1K2008E\u003c\/li\u003e\n\u003cli\u003eZCK-Y35H\u003c\/li\u003e\n\u003cli\u003eD4B-1112N\u003c\/li\u003e\n\u003cli\u003eWL-K12ME-QL\u003c\/li\u003e\n\u003cli\u003eVL-G12-1A25\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUsed for object positioning and detection in automated control systems\u003c\/li\u003e\n\u003cli\u003eCommonly installed on machinery such as CNC mills, laser cutters, and plasma cutting equipment\u003c\/li\u003e\n\u003cli\u003eSuitable for applications in robotics, assembly lines, and industrial automation where a physical limit needs to be detected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSwitch fails to actuate or release consistently\u003c\/li\u003e\n\u003cli\u003eIntermittent or unreliable electrical contact\u003c\/li\u003e\n\u003cli\u003eVisible physical damage to the housing, lever arm, or roller\u003c\/li\u003e\n\u003cli\u003eInternal components are shorted or non-responsive\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAlways disconnect power from the machine before installation or servicing.\u003c\/li\u003e\n\u003cli\u003eEnsure the supply voltage and current do not exceed the switch's AC 250V, 5A rating.\u003c\/li\u003e\n\u003cli\u003eMount the switch securely so that the target object makes firm and consistent contact with the roller lever.\u003c\/li\u003e\n\u003cli\u003eAdjust the lever arm for the correct actuation point and travel distance.\u003c\/li\u003e\n\u003cli\u003eVerify all wiring is correct and connections to the screw terminals are secure.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45369802293437,"sku":"AZ00279885","price":36.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00279885_1_67543eb0-1a70-45f9-9678-db5d0cc715a8.jpg?v=1762246333"},{"product_id":"me8108-momentary-roller-lever-arm-limit-switch-3pack","title":"ME-8108 Momentary Roller Lever Arm Limit Switch for CNC Mill Laser Plasma - 250VAC\/5A - 3 Pack","description":"\u003ch2\u003eME-8108 Momentary Roller Lever Arm Limit Switch\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel: ME-8108\u003c\/li\u003e\n\u003cli\u003eActuator Type: Rotary adjustable roller lever arm\u003c\/li\u003e\n\u003cli\u003eAction Type: Momentary\u003c\/li\u003e\n\u003cli\u003eContact Configuration: 1NO, 1NC (SPDT)\u003c\/li\u003e\n\u003cli\u003eVoltage Rating (Ue): AC 250V, DC 115V\u003c\/li\u003e\n\u003cli\u003eCurrent Rating (Ie): AC 5A, DC 0.4A\u003c\/li\u003e\n\u003cli\u003eEnclosure: Zinc alloy and reinforced plastic construction\u003c\/li\u003e\n\u003cli\u003eDesign: Waterproof and oil-resistant\u003c\/li\u003e\n\u003cli\u003eTerminals: Screw terminals for connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTZ-8108\u003c\/li\u003e\n\u003cli\u003eWLCA2\u003c\/li\u003e\n\u003cli\u003eWLCA2-2\u003c\/li\u003e\n\u003cli\u003eLSA1K2008E\u003c\/li\u003e\n\u003cli\u003eZCK-Y35H\u003c\/li\u003e\n\u003cli\u003eD4B-1112N\u003c\/li\u003e\n\u003cli\u003eWL-K12ME-QL\u003c\/li\u003e\n\u003cli\u003eVL-G12-1A25\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for AC\/DC control circuits in automated machinery\u003c\/li\u003e\n\u003cli\u003eCommonly used in CNC routers, mills, laser cutters, plasma cutters, and 3D printers\u003c\/li\u003e\n\u003cli\u003eSuitable for controlling movement, travel limits, and program control in industrial equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInconsistent or unreliable triggering of the switch\u003c\/li\u003e\n\u003cli\u003eFailure of the machine to stop or home at the correct position\u003c\/li\u003e\n\u003cli\u003eVisible physical damage to the switch housing, lever arm, or roller\u003c\/li\u003e\n\u003cli\u003eSwitch fails continuity tests for normally open (NO) or normally closed (NC) states\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all power to the equipment before starting installation.\u003c\/li\u003e\n\u003cli\u003eMount the switch securely in a position where the moving part of the machine makes firm, consistent contact with the roller lever.\u003c\/li\u003e\n\u003cli\u003eAdjust the lever arm angle for precise actuation at the desired travel limit.\u003c\/li\u003e\n\u003cli\u003eVerify wiring connections (NO or NC) are correct for your machine's control logic.\u003c\/li\u003e\n\u003cli\u003eEnsure wiring is protected from moving parts and environmental hazards.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45369802326205,"sku":"AZ00216135","price":18.11,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00216135_1_dc17af9a-1300-48db-9ae5-e6ca5e06dbcd.jpg?v=1762246333"},{"product_id":"v151c25-micro-limit-switch-blade-momentary-10pack","title":"V-15-1C25 Micro Limit Switch Blade Momentary - 250VAC\/125VDC 15A - 10 Pack","description":"\u003ch2\u003eV-15-1C25 Micro Limit Switch Blade Momentary\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: V-15-1C25\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSwitch Type: SPDT (Single Pole, Double Throw)\u003c\/li\u003e\n\u003cli\u003eContact Configuration: 1 NO (Normally Open), 1 NC (Normally Closed)\u003c\/li\u003e\n\u003cli\u003eAction Type: Momentary, snap action\u003c\/li\u003e\n\u003cli\u003eActuator Type: Short hinge lever\u003c\/li\u003e\n\u003cli\u003eAC Rating: 15A, 1\/2HP at 125\/250VAC\u003c\/li\u003e\n\u003cli\u003eDC Rating: 0.6A at 125VDC, 0.3A at 250VDC\u003c\/li\u003e\n\u003cli\u003eBody Dimensions: 3.8 x 2.1 x 1cm (L*W*H)\u003c\/li\u003e\n\u003cli\u003eConstruction: Plastic body and metal components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect replacement for switches marked with V-15-1C25\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for a wide range of applications including:\u003c\/li\u003e\n\u003cli\u003eAppliance controls\u003c\/li\u003e\n\u003cli\u003eDIY electronics projects (e.g., Arduino)\u003c\/li\u003e\n\u003cli\u003eIndustrial machinery\u003c\/li\u003e\n\u003cli\u003eGeneral purpose electrical equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSwitch no longer actuates or provides an audible click.\u003c\/li\u003e\n\u003cli\u003eCircuit operates intermittently or unreliably.\u003c\/li\u003e\n\u003cli\u003eVisible physical damage, such as a broken lever or cracked housing.\u003c\/li\u003e\n\u003cli\u003eContinuity tests fail for Normally Open or Normally Closed positions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all power to the device before beginning installation.\u003c\/li\u003e\n\u003cli\u003eVerify the voltage and current ratings of the new switch are appropriate for the application.\u003c\/li\u003e\n\u003cli\u003eEnsure the actuator aligns correctly with the machine's moving components.\u003c\/li\u003e\n\u003cli\u003eSecurely fasten electrical connections to the terminals.\u003c\/li\u003e\n\u003cli\u003eTest the switch functionality before restoring full power to the equipment.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45369802424509,"sku":"AZ00108789","price":10.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00108789_1_6dbe8102-df5d-46df-94b6-28cc9868d2a0.jpg?v=1762246331"},{"product_id":"v1531c25-micro-limit-switch-blade-momentary","title":"V-153-1C25 Micro Limit Switch Blade Momentary - 250VAC\/125VDC 15A - 10 Pack","description":"\u003ch2\u003eV-153-1C25 Micro Limit Switch Blade Momentary\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel: V-153-1C25\u003c\/li\u003e\n\u003cli\u003eAction Type: Momentary\u003c\/li\u003e\n\u003cli\u003eActuator Type: Long Straight Hinge Lever\u003c\/li\u003e\n\u003cli\u003eCircuit: SPDT (Single Pole, Double Throw)\u003c\/li\u003e\n\u003cli\u003eContact Configuration: 1NO 1NC (1 Normally Open, 1 Normally Closed)\u003c\/li\u003e\n\u003cli\u003eTerminals: 3-Pin Solder\/Quick Connect\u003c\/li\u003e\n\u003cli\u003eCurrent Rating: 15A at 250VAC\u003c\/li\u003e\n\u003cli\u003eVoltage Rating: 250VAC \/ 125VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eV-153-1C25\u003c\/li\u003e\n\u003cli\u003eV-15-1C25\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGeneral purpose snap-action switch for industrial controls, automation equipment, and appliances.\u003c\/li\u003e\n\u003cli\u003eUsed as a limit switch in various mechanical and electronic systems.\u003c\/li\u003e\n\u003cli\u003eFitment is determined by physical dimensions and electrical ratings. Verify specifications of the original component before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSwitch fails to actuate or release reliably.\u003c\/li\u003e\n\u003cli\u003eIntermittent or complete loss of electrical continuity in either the normally open or normally closed position.\u003c\/li\u003e\n\u003cli\u003ePhysical damage to the switch body, lever arm, or terminals, such as cracking, melting, or corrosion.\u003c\/li\u003e\n\u003cli\u003eThe connected device operates erratically or does not respond to the switch's state change.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all power to the equipment before beginning installation.\u003c\/li\u003e\n\u003cli\u003eConfirm the voltage and amperage ratings of this switch meet or exceed the requirements of your application.\u003c\/li\u003e\n\u003cli\u003eConnect wiring to the appropriate C (Common), NO (Normally Open), and NC (Normally Closed) terminals based on your circuit diagram.\u003c\/li\u003e\n\u003cli\u003eEnsure the switch is mounted securely and the actuator arm has the correct range of motion without over-travel.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45369802490045,"sku":"AZ00138688","price":12.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00138688_1_42b15dab-8444-41d1-b583-7eb790a98f68.jpg?v=1762246331"},{"product_id":"pack-of-10-v1561c25-micro-limit-switch-blade-momentary-250vac125vdc-15a-fit-arduino","title":"V-156-1C25 Micro Limit Switch Blade Momentary - 250VAC\/125VDC 15A - 10 Pack","description":"\u003ch2\u003eV-156-1C25 Micro Limit Switch Blade Momentary 250VAC\/125VDC 15A\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel: V-156-1C25\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eContact Configuration: SPDT (Single-Pole, Double-Throw)\u003c\/li\u003e\n\u003cli\u003eSwitch Action: Momentary\u003c\/li\u003e\n\u003cli\u003eActuator Type: Long hinge roller lever\u003c\/li\u003e\n\u003cli\u003eTerminal Count: 3 (Common, Normally Open, Normally Closed)\u003c\/li\u003e\n\u003cli\u003eAC Rating: 15A at 125\/250VAC\u003c\/li\u003e\n\u003cli\u003eDC Rating: 0.5A at 125VDC; 0.25A at 250VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSS-5GL2\u003c\/li\u003e\n\u003cli\u003eSS-5GL\u003c\/li\u003e\n\u003cli\u003eSHL-W155-01\u003c\/li\u003e\n\u003cli\u003eD4CC-3022\u003c\/li\u003e\n\u003cli\u003eLSE7T\u003c\/li\u003e\n\u003cli\u003eKW11-3Z-1\u003c\/li\u003e\n\u003cli\u003eKW11-7-3Z\u003c\/li\u003e\n\u003cli\u003ePC-H005-D\u003c\/li\u003e\n\u003cli\u003eZM-V156-1C25\u003c\/li\u003e\n\u003cli\u003eTM-V156\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for automation, appliances, and general electrical equipment\u003c\/li\u003e\n\u003cli\u003eSuitable for controlling the movement of mechanical parts in various systems\u003c\/li\u003e\n\u003cli\u003eCompatible with electronic development boards including Arduino, ESP32, ESP8266, and Raspberry Pi\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSwitch fails to actuate or reset consistently\u003c\/li\u003e\n\u003cli\u003eCircuit remains open or closed regardless of actuator position\u003c\/li\u003e\n\u003cli\u003eIntermittent or unreliable electrical contact during operation\u003c\/li\u003e\n\u003cli\u003eVisible signs of physical damage, arcing, or corrosion\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect power from the equipment before installation.\u003c\/li\u003e\n\u003cli\u003eEnsure the actuator is correctly aligned with the moving part it is intended to contact.\u003c\/li\u003e\n\u003cli\u003eVerify wiring to the Common (C), Normally Open (NO), and Normally Closed (NC) terminals based on circuit requirements.\u003c\/li\u003e\n\u003cli\u003eOperate the switch within its specified voltage and current ratings.\u003c\/li\u003e\n\u003cli\u003eSecure the switch body to a fixed surface to prevent movement.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45369802522813,"sku":"AZ00187013","price":19.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00187013_1_f2f96b60-660f-429a-9a07-aaf3f4fe6931.jpg?v=1762246330"},{"product_id":"pack-of-10-kw43z3-micro-limit-switch-lever-arm-28mm-long-with-3-terminals-250vac125vdc-5a","title":"KW4-3Z-3 Micro Limit Switch Lever Arm 28mm Long with 3 Terminals 250VAC\/125VDC 5A - 10 Pack","description":"\u003ch2\u003eKW4-3Z-3 Micro Limit Switch\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel: KW4-3Z-3\u003c\/li\u003e\n\u003cli\u003eActuator: 28mm long hinge lever arm\u003c\/li\u003e\n\u003cli\u003eTerminals: 3-pin configuration for Normally Open (N\/O) and Normally Closed (N\/C) circuits\u003c\/li\u003e\n\u003cli\u003eElectrical Rating: 5A at 125VDC \/ 250VAC\u003c\/li\u003e\n\u003cli\u003eFunction: Snap-action switch designed to control the movement of mechanical parts in electrical systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eKW11-3Z\u003c\/li\u003e\n\u003cli\u003eKW11-3Z-3\u003c\/li\u003e\n\u003cli\u003eSS-01\u003c\/li\u003e\n\u003cli\u003eSS-5\u003c\/li\u003e\n\u003cli\u003eV-15-1C25\u003c\/li\u003e\n\u003cli\u003eD2SW-3L2H\u003c\/li\u003e\n\u003cli\u003eWS2-WBZ3L2B5\u003c\/li\u003e\n\u003cli\u003eLXW5-11G1\u003c\/li\u003e\n\u003cli\u003eZ-15GW22-B\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for use in a wide range of applications including appliances, 3D printers, CNC mills, and other general-purpose electrical automation projects.\u003c\/li\u003e\n\u003cli\u003eFitment depends on matching physical dimensions, actuator type (28mm lever), and electrical specifications (5A, 125\/250V).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSwitch fails to actuate or operates intermittently.\u003c\/li\u003e\n\u003cli\u003eThe circuit remains open or closed regardless of lever position.\u003c\/li\u003e\n\u003cli\u003eVisible damage, such as a broken lever or cracked housing.\u003c\/li\u003e\n\u003cli\u003eAudible click is absent or feels inconsistent during actuation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all power to the equipment before beginning installation.\u003c\/li\u003e\n\u003cli\u003eIdentify and connect wires to the appropriate terminals: Common (C), Normally Open (NO), and Normally Closed (NC).\u003c\/li\u003e\n\u003cli\u003eEnsure the mechanical component correctly engages and releases the lever without excessive force or over-travel.\u003c\/li\u003e\n\u003cli\u003eSecurely mount the switch body to prevent movement during operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45369802555581,"sku":"AZ00249534","price":7.79,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00249534_1_f1d4e923-9899-46ad-8fb3-24e170d6639c.jpg?v=1762246330"},{"product_id":"80bka-type-k-thermocouple-temperature-bead-probe","title":"80BK-A Type K Thermocouple, Temperature Bead Probe - For Clamp Meters, Fluke Multimeter","description":"\u003ch2\u003e80BK-A Type K Thermocouple Temperature Bead Probe\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSensor Type: K-Type Thermocouple\u003c\/li\u003e\n\u003cli\u003eConnector Type: Standard shrouded banana plugs\u003c\/li\u003e\n\u003cli\u003eMeasurement Range: -40°F to 500°F (-40°C to 260°C)\u003c\/li\u003e\n\u003cli\u003eLead Length: 39.4 in (1000 mm)\u003c\/li\u003e\n\u003cli\u003eProbe Tip: Exposed bead for direct contact\u003c\/li\u003e\n\u003cli\u003eApplication: Measures temperature of air, non-corrosive gases, surfaces, and liquids\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e80PK-1\u003c\/li\u003e\n\u003cli\u003e80AK-A\u003c\/li\u003e\n\u003cli\u003eTP80BKA\u003c\/li\u003e\n\u003cli\u003e80BKA\u003c\/li\u003e\n\u003cli\u003e5079037\u003c\/li\u003e\n\u003cli\u003e2091836\u003c\/li\u003e\n\u003cli\u003eTP-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for digital multimeters (DMMs) with a temperature measurement function\u003c\/li\u003e\n\u003cli\u003eCompatible with instruments that accept K-Type thermocouples via standard banana jack inputs\u003c\/li\u003e\n\u003cli\u003eDirect fit for many Fluke multimeters and other brands with compatible inputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature readings are inaccurate, erratic, or unstable\u003c\/li\u003e\n\u003cli\u003eThe multimeter displays an open-loop or \"OL\" error with the probe connected\u003c\/li\u003e\n\u003cli\u003eVisible damage to the wire insulation, bead sensor, or banana plugs\u003c\/li\u003e\n\u003cli\u003eIntermittent readings when the cable is moved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSet the multimeter to the Type-K temperature setting before connecting the probe.\u003c\/li\u003e\n\u003cli\u003eInsert the shrouded banana plugs fully into the correct input jacks on the multimeter, observing polarity markings.\u003c\/li\u003e\n\u003cli\u003eAllow the thermocouple bead sufficient time to reach the temperature of the medium being measured for an accurate reading.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the probe's maximum rated temperature of 500°F (260°C).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45369802621117,"sku":"AZ00187708","price":36.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00187708_1_8fdee1d1-1106-454a-804c-af28d42dfc75.jpg?v=1762246329"},{"product_id":"rtd-pt100-temperature-sensor-probe-3wire-digital","title":"RTD PT100 Temperature Sensor Probe - 3-Wire Digital Thermistor Probe for PID Temperature Controller","description":"\u003ch2\u003eRTD PT100 Temperature Sensor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSensing Element: Platinum Resistance Thermometer (Pt100)\u003c\/li\u003e\n\u003cli\u003eResistance: 100 Ohms at 0°C (32°F)\u003c\/li\u003e\n\u003cli\u003eConfiguration: 3-wire design for enhanced measurement accuracy\u003c\/li\u003e\n\u003cli\u003eProbe Sheath: Stainless steel construction for durability and corrosion resistance\u003c\/li\u003e\n\u003cli\u003eTemperature Range: Varies by model, common ranges include -50°C to 200°C\u003c\/li\u003e\n\u003cli\u003eTermination: Stripped lead wires for connection to terminal blocks or controllers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3FWX3\u003c\/li\u003e\n\u003cli\u003eRTD00576\u003c\/li\u003e\n\u003cli\u003e3290\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with PID temperature controllers, digital thermometers, PLCs, and data acquisition systems that accept a 3-wire Pt100 input.\u003c\/li\u003e\n\u003cli\u003eProbe diameters and lengths vary by model to fit different thermowells and mounting requirements.\u003c\/li\u003e\n\u003cli\u003eAvailable with process connections such as 1\/2 in. NPT threads for secure installation in pipes or vessels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInaccurate, fluctuating, or erratic temperature readings.\u003c\/li\u003e\n\u003cli\u003eController displays an open circuit, short circuit, or sensor error message.\u003c\/li\u003e\n\u003cli\u003eVisible physical damage to the probe sheath, transition, or cable insulation.\u003c\/li\u003e\n\u003cli\u003eNo response to changes in temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the measurement device is configured for a 3-wire Pt100 RTD input.\u003c\/li\u003e\n\u003cli\u003eFor liquid or gas measurement, ensure the sensing portion of the probe is fully immersed in the flow.\u003c\/li\u003e\n\u003cli\u003eDo not bend the cable sharply at the probe transition point.\u003c\/li\u003e\n\u003cli\u003eVerify wire connections are correct per the controller's documentation (typically two common wires and one sense wire).\u003c\/li\u003e\n\u003cli\u003eUse a thermowell for applications in high-pressure or corrosive environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45369802653885,"sku":"AZ00118607","price":15.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00118607_1_d13f0cf3-9cb9-421a-8059-b21f76aa88b2.jpg?v=1762246329"},{"product_id":"ds18b20-1wire-temperature-sensor-waterproof-digital-stainless-steel","title":"DS18B20 1-Wire Temperature Sensor Waterproof Digital Stainless Steel - 5 Pack","description":"\u003ch2\u003eDS18B20 1-Wire Temperature Sensor Digital Stainless Steel 1m\/39.37 inch\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSensor Model: DS18B20\u003c\/li\u003e\n\u003cli\u003eInterface: 1-Wire digital communication protocol\u003c\/li\u003e\n\u003cli\u003eProbe: Waterproof stainless steel housing\u003c\/li\u003e\n\u003cli\u003eProbe Dimensions: 6mm diameter x 30mm length\u003c\/li\u003e\n\u003cli\u003eOperating Voltage: 3.0V to 5.5V\u003c\/li\u003e\n\u003cli\u003eMeasuring Range: -55°C to +125°C (-67°F to +257°F)\u003c\/li\u003e\n\u003cli\u003eAccuracy: ±0.5°C (from -10°C to +85°C)\u003c\/li\u003e\n\u003cli\u003eResolution: Selectable from 9-bit to 12-bit\u003c\/li\u003e\n\u003cli\u003eOutput Wires: VCC (Red), Data (Yellow\/White), GND (Black)\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect replacement for any application using a DS18B20 sensor IC in a waterproof probe configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with microcontrollers and single-board computers supporting the 1-Wire interface, including Arduino, Raspberry Pi, ESP8266, and ESP32.\u003c\/li\u003e\n\u003cli\u003eDesigned for measuring temperature in liquids, soil, and other wet or humid environments.\u003c\/li\u003e\n\u003cli\u003eThe 6mm probe diameter fits standard thermowells and mounting hardware.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSensor fails to appear on the 1-Wire bus.\u003c\/li\u003e\n\u003cli\u003eTemperature readings are erratic, consistently incorrect, or do not update.\u003c\/li\u003e\n\u003cli\u003eVisible physical damage to the cable, heat-shrink seal, or stainless steel probe.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eA 4.7kΩ pull-up resistor is required between the Data and VCC lines for stable communication.\u003c\/li\u003e\n\u003cli\u003eConnect wires to the corresponding VCC, GND, and data pins on your controller.\u003c\/li\u003e\n\u003cli\u003eEnsure the 1-Wire interface is enabled in your device's software configuration (e.g., raspi-config for Raspberry Pi).\u003c\/li\u003e\n\u003cli\u003eMultiple sensors can be connected to the same data pin due to their unique addresses.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45369802686653,"sku":"AZ00155746","price":9.89,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00155746_1_0cf32965-3bc5-43ec-983d-a4a3f98c9f2e.jpg?v=1762246328"},{"product_id":"2pcs-solid-state-relay-ssr25dd","title":"SSR-25DD DC to DC Solid State Relay - 2 Pack","description":"\u003ch2\u003eSSR-25DD Solid State Relay\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eControl Method: DC to DC (DC Input, DC Output)\u003c\/li\u003e\n\u003cli\u003eInput Control Voltage: 3-32V DC\u003c\/li\u003e\n\u003cli\u003eOutput Load Voltage: 5-200V DC\u003c\/li\u003e\n\u003cli\u003eMaximum Load Current: 25A\u003c\/li\u003e\n\u003cli\u003eResponse Time: ≤10ms\u003c\/li\u003e\n\u003cli\u003eDielectric Strength: \u0026gt;2.5KV\u003c\/li\u003e\n\u003cli\u003eDesign: No moving parts for silent operation and extended lifespan. Features an isolated baseplate for efficient heat dissipation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSSR-25DD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for switching high-current DC loads using a low-voltage DC control signal.\u003c\/li\u003e\n\u003cli\u003eCommon applications include industrial automation, CNC machinery, DC motor control, DC heating elements, and robotics.\u003c\/li\u003e\n\u003cli\u003eCompatible with output signals from microcontrollers such as Arduino, Raspberry Pi, and other PLC systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe relay fails to activate the load when a control signal is present.\u003c\/li\u003e\n\u003cli\u003eThe load remains permanently on, even without a control signal.\u003c\/li\u003e\n\u003cli\u003eSwitching becomes intermittent or unreliable.\u003c\/li\u003e\n\u003cli\u003eThe relay overheats excessively during operation, indicating internal failure.\u003c\/li\u003e\n\u003cli\u003eVisible physical damage, such as cracks, burns, or melted housing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all power sources before installation or service.\u003c\/li\u003e\n\u003cli\u003eA heat sink is required for load currents exceeding 10A to ensure proper thermal management and prevent overheating.\u003c\/li\u003e\n\u003cli\u003eApply a thin layer of thermal paste between the relay's metal base and the heat sink for optimal heat transfer.\u003c\/li\u003e\n\u003cli\u003eEnsure all wire connections are secure to prevent poor contact and potential arcing.\u003c\/li\u003e\n\u003cli\u003eVerify correct polarity for both the DC input (control) and DC output (load) terminals.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45369803210941,"sku":"AZ00158041","price":15.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00225134_1_32dfd7b3-f61e-41b4-9ff3-e3e7036febcf.jpg?v=1762246321"},{"product_id":"ssr25aa-solid-state-relay-2pack","title":"SSR-25AA AC to AC Solid State Relay - 2 Pack","description":"\u003ch2\u003eSSR-25AA Solid State Relay\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel: SSR-25AA\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eType: Single Phase Solid State Relay (AC to AC)\u003c\/li\u003e\n\u003cli\u003eControl Input Voltage: 80-250V AC\u003c\/li\u003e\n\u003cli\u003eLoad Output Voltage: 24-380V AC\u003c\/li\u003e\n\u003cli\u003eMaximum Load Current: 25A\u003c\/li\u003e\n\u003cli\u003eSwitching Method: Electronic, non-mechanical for high-speed operation\u003c\/li\u003e\n\u003cli\u003eConstruction: Features an integrated aluminum heat-dissipating base plate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSSR-40AA\u003c\/li\u003e\n\u003cli\u003eRM1A23A25\u003c\/li\u003e\n\u003cli\u003eRA2425D\u003c\/li\u003e\n\u003cli\u003eD2425-10\u003c\/li\u003e\n\u003cli\u003eRN1A23D25\u003c\/li\u003e\n\u003cli\u003e240A25\u003c\/li\u003e\n\u003cli\u003eSSR-25AA-H\u003c\/li\u003e\n\u003cli\u003eS2225X\u003c\/li\u003e\n\u003cli\u003e25A-H3-380VAC\u003c\/li\u003e\n\u003cli\u003eRJ1A48D25\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cp\u003eA general-purpose component for switching AC electrical loads. Suitable for applications within its specified voltage and amperage ratings, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial automation and process control\u003c\/li\u003e\n\u003cli\u003eProgrammable Logic Controller (PLC) interface\u003c\/li\u003e\n\u003cli\u003eHeating element and motor control\u003c\/li\u003e\n\u003cli\u003eLighting systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRelay fails to activate the load circuit when control voltage is applied.\u003c\/li\u003e\n\u003cli\u003eRelay remains in the \"on\" state, continuously powering the load circuit regardless of control voltage.\u003c\/li\u003e\n\u003cli\u003eIntermittent or unreliable switching performance.\u003c\/li\u003e\n\u003cli\u003eVisible signs of damage or overheating on the relay housing or terminals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all power sources before installation or servicing.\u003c\/li\u003e\n\u003cli\u003eA heat sink is required for reliable operation with loads exceeding 10A to prevent thermal failure.\u003c\/li\u003e\n\u003cli\u003eApply a thin layer of thermal compound between the relay's metal base and the heat sink surface.\u003c\/li\u003e\n\u003cli\u003eEnsure all wire connections to the screw terminals are secure to prevent poor contact and overheating.\u003c\/li\u003e\n\u003cli\u003eVerify that your application's control and load voltages are within the specified ranges for this relay.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45369803407549,"sku":"AZ00225069","price":16.19,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00389918_1_7142295e-5397-44c0-ba70-88f3261e64a0.jpg?v=1762246318"},{"product_id":"472286101-limit-switches-l350-furnace-bimetal-thermostat","title":"47-22861-01 Limit Switches L350 Furnace Bimetal Thermostat Switch - 250V\/10A","description":"\u003ch2\u003e47-22861-01 Furnace Flame Rollout Limit Switch L350\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBimetal disc design for temperature sensing\u003c\/li\u003e\n\u003cli\u003eProvides high-limit temperature protection\u003c\/li\u003e\n\u003cli\u003eFixed temperature cutout at 350°F (L350)\u003c\/li\u003e\n\u003cli\u003eSingle Pole, Single Throw (SPST) switch configuration\u003c\/li\u003e\n\u003cli\u003eDesigned for use in residential and light commercial HVAC systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e47-22861-01\u003c\/li\u003e\n\u003cli\u003e47-22861-01K\u003c\/li\u003e\n\u003cli\u003e47-22861-02\u003c\/li\u003e\n\u003cli\u003eL350F\u003c\/li\u003e\n\u003cli\u003eSRL350\u003c\/li\u003e\n\u003cli\u003e350F\u003c\/li\u003e\n\u003cli\u003e36TX16\u003c\/li\u003e\n\u003cli\u003e47-100241-01\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect replacement for Rheem furnaces requiring part number 47-22861-01\u003c\/li\u003e\n\u003cli\u003eFits various HVAC systems that specify a 350°F SPST high-limit switch\u003c\/li\u003e\n\u003cli\u003eVerify compatibility by checking the part number and temperature rating on the original switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace blower runs continuously after the heating cycle stops\u003c\/li\u003e\n\u003cli\u003eHeating cycle stops prematurely and restarts frequently (short cycling)\u003c\/li\u003e\n\u003cli\u003eFurnace fails to ignite or produce heat due to an open limit circuit\u003c\/li\u003e\n\u003cli\u003eThe original switch fails a continuity test with a multimeter when at room temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all electrical power to the furnace before beginning installation\u003c\/li\u003e\n\u003cli\u003eLocate the existing limit switch, typically mounted on the furnace plenum or near the heat exchanger\u003c\/li\u003e\n\u003cli\u003eNote the wire connections before removing the old switch\u003c\/li\u003e\n\u003cli\u003eRemove mounting screws and wires from the original switch\u003c\/li\u003e\n\u003cli\u003eInstall the new switch, ensuring it is securely fastened\u003c\/li\u003e\n\u003cli\u003eReconnect wires to the terminals on the new switch\u003c\/li\u003e\n\u003cli\u003eRestore power and run the furnace through a complete heating cycle to verify correct operation\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45369804456125,"sku":"AZ00193376","price":8.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00151811_1_a5838009-250b-4e2d-85ef-8330b1274610.jpg?v=1762246313"},{"product_id":"1-pole-30-amp-24v-contactor","title":"1 Pole 30 Amp 24V Contactor","description":"\u003ch2\u003e1 Pole 30 Amp 24V Contactor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eType: Definite Purpose Contactor\u003c\/li\u003e\n  \u003cli\u003ePoles: 1 (Single Pole)\u003c\/li\u003e\n  \u003cli\u003eCoil Voltage: 24 VAC\u003c\/li\u003e\n  \u003cli\u003eAmperage Rating: 30 Amps (Full Load)\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eTerminals: Box lugs and spade terminals\u003c\/li\u003e\n  \u003cli\u003eIncludes protective dust cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePACKARD: C130A\u003c\/li\u003e\n  \u003cli\u003eEaton: DP30241\u003c\/li\u003e\n  \u003cli\u003eHoneywell: 168215\u003c\/li\u003e\n  \u003cli\u003eLennox: 3100-15Q108\u003c\/li\u003e\n  \u003cli\u003eRheem: 4250-66, 425066\u003c\/li\u003e\n  \u003cli\u003eTCDP301B6\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned for use in HVAC systems and other electrical applications.\u003c\/li\u003e\n  \u003cli\u003eCommonly installed in outdoor air conditioning and heat pump condensing units, typically from 1.5 to 3.5 tons.\u003c\/li\u003e\n  \u003cli\u003eFunctions as a direct replacement for parts with matching specifications (1 pole, 30 amp, 24V coil).\u003c\/li\u003e\n  \u003cli\u003eFits equipment from brands such as Trane, Rheem, Lennox, and Eaton that use a contactor with these ratings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOutdoor unit does not activate when the thermostat signals for operation.\u003c\/li\u003e\n  \u003cli\u003eA loud humming or buzzing sound is heard from the unit without the fan or compressor starting.\u003c\/li\u003e\n  \u003cli\u003eVisible signs of damage, including burnt, pitted, or corroded electrical contacts.\u003c\/li\u003e\n  \u003cli\u003eThe contactor remains stuck in the on position, causing the unit to run constantly.\u003c\/li\u003e\n  \u003cli\u003eThe internal coil fails a continuity test with a multimeter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eBefore installation, disconnect all electrical power to the unit at the main circuit breaker and the local service disconnect.\u003c\/li\u003e\n  \u003cli\u003eUse a multimeter to verify that no voltage is present at the contactor terminals.\u003c\/li\u003e\n  \u003cli\u003ePhotograph or label the wiring configuration of the old contactor before removal.\u003c\/li\u003e\n  \u003cli\u003eEnsure the new contactor is mounted securely in the control panel.\u003c\/li\u003e\n  \u003cli\u003eConfirm all wire connections are tight and fully seated on the correct terminals.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45369804685501,"sku":"AZ00952618","price":11.94,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00952618_1_3956ead6-ad02-4a1a-8924-ce3afa60cfb0.jpg?v=1762246313"},{"product_id":"2pack-ssr40da-solid-state-relay","title":"SSR-40DA DC to AC Solid State Relay - 2 Pack","description":"\u003ch2\u003eSSR-40DA Solid State Relay\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel: SSR-40DA\u003c\/li\u003e\n\u003cli\u003eControl Method: DC to AC\u003c\/li\u003e\n\u003cli\u003eInput Voltage: 3-32V DC\u003c\/li\u003e\n\u003cli\u003eLoad Voltage: 24-380V AC\u003c\/li\u003e\n\u003cli\u003eLoad Current: 40A\u003c\/li\u003e\n\u003cli\u003eSwitching Mechanism: Electronic, no mechanical parts\u003c\/li\u003e\n\u003cli\u003eTrigger Type: Zero-cross\u003c\/li\u003e\n\u003cli\u003eConnections: 4 screw terminals for input and output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSSR-40DA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGeneral-purpose component for controlling high-current AC loads with a low-voltage DC signal.\u003c\/li\u003e\n\u003cli\u003eSuitable for automatic control systems, including temperature controllers, HVAC systems, and industrial machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRelay fails to activate when input voltage is applied.\u003c\/li\u003e\n\u003cli\u003eRelay remains stuck in the \"ON\" position, even with no input voltage.\u003c\/li\u003e\n\u003cli\u003eIntermittent or unreliable switching of the AC load.\u003c\/li\u003e\n\u003cli\u003eVisible signs of damage, overheating, or melting on the relay housing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all power to the system before installation.\u003c\/li\u003e\n\u003cli\u003eA heat sink is recommended for loads approaching the 40A rating to ensure proper heat dissipation.\u003c\/li\u003e\n\u003cli\u003eEnsure all screw terminals are securely fastened to prevent arcing.\u003c\/li\u003e\n\u003cli\u003eVerify that the wire gauge used is appropriate for the electrical load.\u003c\/li\u003e\n\u003cli\u003eConfirm input and output connections are correct before applying power.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45369807175869,"sku":"AZ00161427","price":15.6,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00136914_1_242a6d5b-fcb2-48f2-a2dd-5941f935c15b.jpg?v=1762246311"},{"product_id":"2pack-bme280-33v-atmospheric-pressure-sensor","title":"GY-BME280 BME280 Digital 3.3V Atmospheric Pressure Sensor - 2 Pack","description":"\u003ch2\u003eBME280 3.3V Atmospheric Pressure Sensor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated sensor for measuring atmospheric pressure, humidity, and temperature.\u003c\/li\u003e\n\u003cli\u003eDual communication interface support for both I2C and SPI protocols.\u003c\/li\u003e\n\u003cli\u003eOnboard voltage regulator and level shifter for compatibility with 3.3V and 5V logic.\u003c\/li\u003e\n\u003cli\u003ePressure measurement range: 300 to 1100 hPa.\u003c\/li\u003e\n\u003cli\u003eTemperature measurement range: -40°C to +85°C.\u003c\/li\u003e\n\u003cli\u003eHumidity measurement range: 0% to 100% relative humidity.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBME280\u003c\/li\u003e\n\u003cli\u003eGY-BME280\u003c\/li\u003e\n\u003cli\u003eFunctional upgrade for BMP280, BMP180, and BMP085 sensors (adds humidity sensing and higher precision).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for use with microcontrollers such as Arduino, ESP32, ESP8266, and Raspberry Pi.\u003c\/li\u003e\n\u003cli\u003eSuitable for a wide range of applications:\n\u003cul\u003e\n\u003cli\u003eWeather stations and environmental monitoring\u003c\/li\u003e\n\u003cli\u003eIndoor climate control and HVAC systems\u003c\/li\u003e\n\u003cli\u003eAltimetry and barometry for drones or personal navigation\u003c\/li\u003e\n\u003cli\u003eHome automation projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSensor fails to provide readings or sends intermittent data.\u003c\/li\u003e\n\u003cli\u003eReadings for pressure, temperature, or humidity are static or inaccurate.\u003c\/li\u003e\n\u003cli\u003eModule is no longer detected on the I2C or SPI bus.\u003c\/li\u003e\n\u003cli\u003ePhysical damage to the PCB or sensor element is visible.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConnect VCC to a 3.3V or 5V power supply and GND to ground.\u003c\/li\u003e\n\u003cli\u003eFor I2C mode, connect the SCL and SDA pins to the microcontroller's corresponding I2C pins.\u003c\/li\u003e\n\u003cli\u003eFor SPI mode, connect SCK, SDO, SDI, and CS pins to the microcontroller's SPI interface.\u003c\/li\u003e\n\u003cli\u003eTo ensure accurate temperature data, position the sensor away from heat-generating components.\u003c\/li\u003e\n\u003cli\u003eProtect the sensing element from direct exposure to dust, liquids, and physical contact.\u003c\/li\u003e\n\u003cli\u003eRefer to the component datasheet for I2C addressing and register information.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45369808388285,"sku":"AZ00102369","price":7.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00122621_1_3ef0f943-b366-4496-99d9-848bd0712276.jpg?v=1762246311"},{"product_id":"rtd-temperature-probe-sensor","title":"RTD Temperature Probe Sensor - Meat Probe Sensor PB1000XL-025-R00 V2 (70123-AMP)","description":"\u003ch2\u003eRTD Temperature Probe Sensor - Compatible with Pit Boss Pellet Grills and Smoker, Meat Probe Sensor PB1000XL-025-R00 V2 (70123-AMP)\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitors the internal temperature of your pellet grill or smoker.\u003c\/li\u003e\n\u003cli\u003eConstructed with a stainless steel probe and a high-temperature wire lead.\u003c\/li\u003e\n\u003cli\u003eIncludes one temperature probe, two screws, and two spade connectors for a complete replacement.\u003c\/li\u003e\n\u003cli\u003eDesigned to provide consistent temperature data to the digital control board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e70123-AMP\u003c\/li\u003e\n\u003cli\u003ePB1000XL-025-R00 V2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBrand: Pit Boss\u003c\/li\u003e\n\u003cli\u003eCompatible with models using horizontal control boards such as CAT-02-PG or AC03P9.\u003c\/li\u003e\n\u003cli\u003eFits various models including the 700 Series, 820 Series, Tailgater, Classic, Austin XL, and all vertical smokers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe digital controller displays \"ErP\" or other probe-related error codes.\u003c\/li\u003e\n\u003cli\u003eThe grill experiences large, erratic temperature swings.\u003c\/li\u003e\n\u003cli\u003eThe displayed temperature is inaccurate compared to a calibrated thermometer.\u003c\/li\u003e\n\u003cli\u003eThe probe or its wiring is physically damaged, frayed, or broken.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect the grill from its power source before beginning installation.\u003c\/li\u003e\n\u003cli\u003eLocate the existing RTD probe inside the main cooking chamber.\u003c\/li\u003e\n\u003cli\u003eUnscrew the old probe and disconnect its wiring from the controller.\u003c\/li\u003e\n\u003cli\u003eSecure the new probe in place using the included screws.\u003c\/li\u003e\n\u003cli\u003eConnect the new probe's wires to the corresponding terminals on the control board.\u003c\/li\u003e\n\u003cli\u003eEnsure the probe tip does not touch any internal components for accurate readings.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45369813532861,"sku":"AZ00104816","price":20.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00104816_1_922a8570-d360-4f27-917c-30ae99067eb2.jpg?v=1765275976"},{"product_id":"ssr25aa-solid-state-relay","title":"SSR-25AA AC to AC Solid State Relay","description":"\u003ch2\u003eSSR-25AA Solid State Relay\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel: SSR-25AA\u003c\/li\u003e\n\u003cli\u003eType: Single-Phase AC-to-AC Solid State Relay\u003c\/li\u003e\n\u003cli\u003eControl Input Voltage: 80-250V AC\u003c\/li\u003e\n\u003cli\u003eLoad Output Voltage: 24-380V AC\u003c\/li\u003e\n\u003cli\u003eMaximum Load Current: 25A\u003c\/li\u003e\n\u003cli\u003eSwitching Method: Zero-crossing trigger\u003c\/li\u003e\n\u003cli\u003eOperation: Silent, no-spark, high-speed switching\u003c\/li\u003e\n\u003cli\u003eConstruction: Features an integrated metal baseplate for heat dissipation\u003c\/li\u003e\n\u003cli\u003eDimensions: 5.8 x 4.5 x 2.2 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSSR-40AA\u003c\/li\u003e\n\u003cli\u003eRM1A23A25\u003c\/li\u003e\n\u003cli\u003eRA2425D\u003c\/li\u003e\n\u003cli\u003eD2425-10\u003c\/li\u003e\n\u003cli\u003eRN1A23D25\u003c\/li\u003e\n\u003cli\u003e240A25\u003c\/li\u003e\n\u003cli\u003eSSR-25AA-H\u003c\/li\u003e\n\u003cli\u003eS2225X\u003c\/li\u003e\n\u003cli\u003e25A-H3-380VAC\u003c\/li\u003e\n\u003cli\u003eRJ1A48D25\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for general purpose AC load switching in industrial automation, process control systems, and machinery.\u003c\/li\u003e\n\u003cli\u003eCompatible with control circuits providing an 80-250V AC signal.\u003c\/li\u003e\n\u003cli\u003eSuitable for resistive and inductive AC loads up to 25A within a 24-380V AC voltage range.\u003c\/li\u003e\n\u003cli\u003eRequires a heat sink (not included) for operation near maximum rated current to prevent thermal damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe connected load circuit remains permanently on or off.\u003c\/li\u003e\n\u003cli\u003eRelay fails to activate when control voltage is applied.\u003c\/li\u003e\n\u003cli\u003eIntermittent or unreliable switching performance.\u003c\/li\u003e\n\u003cli\u003eVisible signs of overheating, melting, or physical damage to the housing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all power to the circuit before installation or removal.\u003c\/li\u003e\n\u003cli\u003eEnsure correct wiring for input (control) and output (load) terminals.\u003c\/li\u003e\n\u003cli\u003eApply a thin layer of thermal compound between the relay's metal base and the mounting heat sink.\u003c\/li\u003e\n\u003cli\u003eSecurely fasten the relay to a heat sink appropriately sized for your specific load current.\u003c\/li\u003e\n\u003cli\u003eVerify that the control signal and load voltage\/current are within the specified ratings of the relay.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45369817333949,"sku":"AZ33439090","price":10.79,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00144264_1_c26f97d1-a4fe-4d2b-b56b-e12717978dfb.jpg?v=1762246299"},{"product_id":"68086693ac-driver-side-power-master-window-switch","title":"68086693AC Driver Side Power Master Window Switch","description":"\u003ch2\u003e68086693AC Driver Side Power Master Window Switch\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLocation: Front Left (Driver Side)\u003c\/li\u003e\n\u003cli\u003eControls: All 4 power windows, window lock, door locks, and power mirrors\u003c\/li\u003e\n\u003cli\u003eWindow Functionality: One-touch automatic up\/down for both front windows\u003c\/li\u003e\n\u003cli\u003eConnector: 11-pin (8+3 pin configuration)\u003c\/li\u003e\n\u003cli\u003eIllumination: Blue backlighting on buttons\u003c\/li\u003e\n\u003cli\u003eConstruction: Matches original equipment specifications for fit, form, and function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e68086693AC\u003c\/li\u003e\n\u003cli\u003e68086693AD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDodge Durango:\u003c\/strong\u003e 2011-2022\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJeep Grand Cherokee:\u003c\/strong\u003e 2011-2013\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne or more power windows fail to operate from the master switch.\u003c\/li\u003e\n\u003cli\u003eWindow lock, door lock, or mirror adjustment functions are inoperable.\u003c\/li\u003e\n\u003cli\u003eSwitch buttons are physically broken, unresponsive, or operate intermittently.\u003c\/li\u003e\n\u003cli\u003eControl of a specific window only works from its individual door switch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThis is a direct-fit replacement part with a plug-in connector.\u003c\/li\u003e\n\u003cli\u003eDisconnect the vehicle's negative battery terminal before starting.\u003c\/li\u003e\n\u003cli\u003eCarefully pry the door panel or switch bezel using a non-marring trim removal tool.\u003c\/li\u003e\n\u003cli\u003eDisconnect the electrical connectors by depressing the release tabs.\u003c\/li\u003e\n\u003cli\u003eRemove the old switch and install the new unit, ensuring all clips are securely fastened.\u003c\/li\u003e\n\u003cli\u003eReconnect the electrical harnesses, reassemble the door panel, and test all functions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45371214233789,"sku":"AZ00184196","price":19.79,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00184196_1_78b4b61c-0eee-4648-a50c-3811e6e7b546.jpg?v=1762246241"},{"product_id":"2134777-engine-coolant-temperature-sensor","title":"213-4777 Engine Coolant Temperature Sensor","description":"\u003ch2\u003e213-4777 Engine Coolant Temperature Sensor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitors engine coolant temperature to provide critical data to the engine control module.\u003c\/li\u003e\n\u003cli\u003eEnsures the engine operates within its optimal temperature range for performance and efficiency.\u003c\/li\u003e\n\u003cli\u003eTriggers high-temperature warnings on the instrument panel.\u003c\/li\u003e\n\u003cli\u003eManufactured to original equipment (OE) specifications for fit, form, and function.\u003c\/li\u003e\n\u003cli\u003eFeatures a two-terminal electrical connector.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eACDelco: 213-4777\u003c\/li\u003e\n\u003cli\u003eGeneral Motors (GM): 12639899\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned as a direct-fit original equipment replacement for a wide range of General Motors vehicles.\u003c\/li\u003e\n\u003cli\u003ePlease verify compatibility with your specific year, make, model, and engine before purchase.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInaccurate or fluctuating temperature gauge readings.\u003c\/li\u003e\n\u003cli\u003eEngine overheating or running too cool.\u003c\/li\u003e\n\u003cli\u003eIlluminated Check Engine Light (CEL) with relevant fault codes.\u003c\/li\u003e\n\u003cli\u003eNoticeable decrease in fuel economy.\u003c\/li\u003e\n\u003cli\u003eDifficulty starting the engine, especially when cold.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAllow the engine to cool completely before beginning the replacement.\u003c\/li\u003e\n\u003cli\u003ePartially drain the cooling system to a level below the sensor's location to minimize coolant loss.\u003c\/li\u003e\n\u003cli\u003eClean the sensor's threaded port before installing the new component.\u003c\/li\u003e\n\u003cli\u003eTorque the new sensor to the vehicle manufacturer's specified value.\u003c\/li\u003e\n\u003cli\u003eAfter installation, refill and bleed the cooling system according to the service manual.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45371216855229,"sku":"AZ00680396","price":14.71,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00199136_1_d1b6178e-f3fd-4d04-ab20-a6cc9cd6fa27.jpg?v=1762246216"},{"product_id":"75inch-throttle-cable","title":"75-inch Throttle Cable","description":"\u003ch2\u003e75-inch Throttle Cable for Go Karts, Mini Bikes, and Pit Bikes\u003c\/h2\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTotal cable length of 75 inches (approximately 190.5 cm) for extended reach on long-frame karts and buggies.\u003c\/li\u003e\n\u003cli\u003eHigh-tensile braided steel inner wire provides responsive, low-friction throttle control.\u003c\/li\u003e\n\u003cli\u003eDurable, weather-resistant outer housing protects against moisture, grit, and corrosion.\u003c\/li\u003e\n\u003cli\u003eStandard barrel-style connector for secure attachment to gas pedals and twist-grip assemblies.\u003c\/li\u003e\n\u003cli\u003eIntegrated threaded adjuster allows for precise cable tensioning and idle synchronization at the carburetor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e75-inch Universal Throttle Cable\u003c\/li\u003e\n\u003cli\u003eKandi GKA Cable\u003c\/li\u003e\n\u003cli\u003eYerf-Dog 3203 \/ 30033 Cable\u003c\/li\u003e\n\u003cli\u003eBlack Widow Go Kart Cable\u003c\/li\u003e\n\u003cli\u003e90cc-250cc Buggy Throttle Line\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGo Karts \u0026amp; Buggies:\u003c\/strong\u003e Kandi GKA, Black Widow, Hammerhead, TrailMaster, and Carter Brothers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMini Bikes \u0026amp; Scooters:\u003c\/strong\u003e Yerf-Dog, Coleman, and various gas-powered stand-up or sit-down scooters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngines:\u003c\/strong\u003e Compatible with 90cc, 110cc, 125cc, 150cc, 200cc, and 250cc GY6 or horizontal OHV engines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirt Bikes:\u003c\/strong\u003e Fits many pit bikes and off-road motorcycles requiring an extended-length cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThrottle sticks, binds, or fails to return to the idle position promptly.\u003c\/li\u003e\n\u003cli\u003eInner steel wire is frayed, kinked, or has snapped completely.\u003c\/li\u003e\n\u003cli\u003eOuter protective housing is cracked, melted, or crushed, restricting internal movement.\u003c\/li\u003e\n\u003cli\u003eThe adjustment nut is stripped or the barrel end has detached from the cable.\u003c\/li\u003e\n\u003cli\u003eExcessive slack in the throttle pedal that cannot be corrected with standard adjustments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRoute the new cable along the vehicle frame, ensuring it is kept away from the exhaust and moving suspension parts.\u003c\/li\u003e\n\u003cli\u003eAvoid sharp 90-degree bends which can cause internal friction and premature wear.\u003c\/li\u003e\n\u003cli\u003eAttach the barrel end to the throttle actuator (pedal or grip) before connecting to the carburetor.\u003c\/li\u003e\n\u003cli\u003eEnsure the inner wire is properly seated in the carburetor slide or butterfly valve linkage.\u003c\/li\u003e\n\u003cli\u003eUse the threaded adjuster to remove excess play; there should be a small amount of \"free play\" (approx. 1\/8 inch) before the throttle engages.\u003c\/li\u003e\n\u003cli\u003eSecure the housing to the frame using heat-resistant ties to prevent the cable from snagging during off-road use.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45371217903805,"sku":"AZ00178162","price":15.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00178162_1_895dd8f9-e84d-4bf6-823c-222eb5e02f24.jpg?v=1762246191"},{"product_id":"electric-scooter-thumb-throttle-compatible-with-gxl-v2apexapex-proapex-xlxr-elite","title":"Electric Scooter Thumb Throttle For GXL V2\/Apex\/Apex Pro\/Apex XL\/XR Elite","description":"\u003ch2\u003eElectric Scooter Thumb Throttle Compatible with GXL V2\/Apex\/Apex Pro\/Apex XL\/XR Elite\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eDirect replacement thumb-activated accelerator assembly.\u003c\/li\u003e\n    \u003cli\u003eFeatures an ergonomic design with enhanced grip texture.\u003c\/li\u003e\n    \u003cli\u003eIncludes integrated cruise control activation button.\u003c\/li\u003e\n    \u003cli\u003eEquipped with a standard 3-wire harness connector.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eReplaces the original equipment manufacturer (OEM) thumb throttle on all compatible models.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cb\u003eGOTRAX:\u003c\/b\u003e GXL V2, Apex, Apex Pro, Apex XL, XR Elite\u003c\/li\u003e\n    \u003cli\u003e\n\u003cb\u003eHiboy:\u003c\/b\u003e S2, S2 Pro\u003c\/li\u003e\n    \u003cli\u003e\n\u003cb\u003eMegawheel:\u003c\/b\u003e S10\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eThrottle is unresponsive or provides intermittent power.\u003c\/li\u003e\n    \u003cli\u003ePhysical damage to the lever, button, or housing.\u003c\/li\u003e\n    \u003cli\u003eCruise control function fails to engage or disengage.\u003c\/li\u003e\n    \u003cli\u003eThe scooter displays throttle-specific error codes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eEnsure the scooter is powered off and the battery is disconnected before beginning.\u003c\/li\u003e\n    \u003cli\u003eCarefully remove the handlebar grip to access the throttle assembly.\u003c\/li\u003e\n    \u003cli\u003eNote the wire routing before unplugging the old component.\u003c\/li\u003e\n    \u003cli\u003eSecurely fasten the new throttle to the handlebar before reconnecting the wiring.\u003c\/li\u003e\n    \u003cli\u003eTest for proper function before riding.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45371218723005,"sku":"AZ00125892","price":18.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00125892_1_280e5950-1ad3-40b4-bc9b-4c13da541e03.jpg?v=1762246184"},{"product_id":"84-inch-go-kart-throttle-cable-compatible-with-kt196-196cc212cc224cc-engines","title":"84 Inch Go Kart Throttle Cable - For KT196, 196cc\/212cc\/224cc Engines","description":"\u003ch2\u003e84 Inch Go Kart Throttle Cable - Compatible with KT196, 196cc\/212cc\/224cc Engines\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTotal Cable Length: 84 inches\u003c\/li\u003e\n\u003cli\u003eConstructed with a durable inner wire and protective outer housing\u003c\/li\u003e\n\u003cli\u003eIncludes throttle cable and two return springs for a complete installation\u003c\/li\u003e\n\u003cli\u003eEngineered for direct replacement of the original equipment cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect replacement for the stock throttle cable on specified go kart models and engines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGo Kart Models:\u003c\/strong\u003e Coleman KT196, Coleman CK196, Hisun HS200GK\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngines:\u003c\/strong\u003e Predator 196cc, 212cc, and 224cc engines (typically 5.5hp and 6.5hp variants)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThrottle pedal feels stiff, sticky, or does not operate smoothly\u003c\/li\u003e\n\u003cli\u003eCable is visibly frayed, kinked, corroded, or broken\u003c\/li\u003e\n\u003cli\u003eEngine throttle does not return to idle position consistently\u003c\/li\u003e\n\u003cli\u003eInconsistent or unresponsive throttle control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the engine is off and cool before beginning work.\u003c\/li\u003e\n\u003cli\u003eRoute the new cable following the same path as the original to prevent binding or pinching.\u003c\/li\u003e\n\u003cli\u003eConfirm the throttle mechanism moves freely from idle to full open and back after installation.\u003c\/li\u003e\n\u003cli\u003eAdjust cable tension to remove excess slack without holding the throttle open at idle.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45371218788541,"sku":"AZ00203869","price":26.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00127788_1_fbf59fcf-370d-4f73-92d0-d531293d0692.jpg?v=1762246182"},{"product_id":"throttle-cruise-controlmotorcycle-throttle-lock","title":"Throttle Cruise Control\/Motorcycle Throttle Lock","description":"\u003ch2\u003eUniversal Motorcycle Throttle Cruise Control \/ Throttle Lock\u003c\/h2\u003e\n\u003cp\u003e\nThis throttle cruise control assist is designed to help maintain a steady speed while riding, allowing you to relax your right hand and reduce wrist fatigue. It is a practical and reliable accessory for daily riding and long-distance trips.\n\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eImportant Note:\u003c\/strong\u003e Package includes \u003cstrong\u003e1 throttle cruise control\u003c\/strong\u003e. Please carefully check the measurements before purchasing to ensure proper fit.\n\u003c\/p\u003e\n\n\u003ch3\u003eReliable Throttle Control\u003c\/h3\u003e\n\u003cp\u003e\nThe motorcycle throttle lock securely holds the throttle in position, helping maintain a consistent cruising speed. This reduces strain on your wrist and hand, minimizing fatigue and discomfort during extended rides.\n\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eOne-click release design for quick and easy disengagement\u003c\/li\u003e\n  \u003cli\u003eAllows fast response to changing riding conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eUniversal Fit\u003c\/h3\u003e\n\u003cp\u003e\nWith an adjustable diameter range of \u003cstrong\u003e1.18\" to 1.57\"\u003c\/strong\u003e, this throttle control assist fits most handlebar sizes and is suitable for a wide range of vehicles, including:\n\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotorcycles\u003c\/li\u003e\n  \u003cli\u003eStreet bikes\u003c\/li\u003e\n  \u003cli\u003eElectric bikes\u003c\/li\u003e\n  \u003cli\u003eScooters\u003c\/li\u003e\n  \u003cli\u003eATVs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\nCompatible with popular brands such as Honda, Yamaha, Ducati, Harley-Davidson, BMW, Kawasaki, Suzuki, and more.\n\u003c\/p\u003e\n\n\u003ch3\u003eSuperior Quality Construction\u003c\/h3\u003e\n\u003cp\u003e\nMade from high-strength ABS plastic, this throttle cruise control offers excellent durability and resistance to rust, weather exposure, and wear. It is designed to withstand vibration while preventing slippage, ensuring safe and reliable performance. The sleek design also adds a stylish touch to your vehicle.\n\u003c\/p\u003e\n\n\u003ch3\u003eEasy Installation \u0026amp; Use\u003c\/h3\u003e\n\u003cp\u003e\nThe throttle lock is easy to install, remove, and maintain. Simply attach it to the handlebar, press it against the brake lever, and rotate the lock to set your desired cruising speed. Once set, enjoy a more relaxed riding experience.\n\u003c\/p\u003e\n","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45371218952381,"sku":"AZ00279789","price":27.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00189078_1.jpg?v=1757330093"},{"product_id":"2-pole-contactor-30-amp-240vac-coil","title":"2 Pole Contactor 30 Amp 240VAC Coil - For Relays, Air Conditioner, Heat Pump, Refrigeration Systems","description":"\u003ch2\u003e2 Pole Contactor 30 Amp 240VAC Coil\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePoles: 2 Pole, Single Phase\u003c\/li\u003e\n\u003cli\u003eFull Load Amps (FLA): 30A\u003c\/li\u003e\n\u003cli\u003eResistive Load Amps (RES): 40A\u003c\/li\u003e\n\u003cli\u003eCoil Voltage: 240VAC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eMaximum Voltage Rating: 600V\u003c\/li\u003e\n\u003cli\u003eTerminal Type: Screw\u003c\/li\u003e\n\u003cli\u003eEnclosed contacts for protection against dust and debris\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCan replace 2-pole contactors with ratings of 20A, 25A, and 30A.\u003c\/li\u003e\n\u003cli\u003eDirect replacement for Supco DP302402.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for use in residential and commercial HVAC systems.\u003c\/li\u003e\n\u003cli\u003eApplications include air conditioners, heat pumps, condenser units, and refrigeration systems.\u003c\/li\u003e\n\u003cli\u003eFits systems requiring a 2-pole definite purpose contactor with a 30 Amp rating and 240VAC coil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit (condenser) fails to start or runs intermittently.\u003c\/li\u003e\n\u003cli\u003eCompressor or fan motor does not engage when the system calls for cooling or heating.\u003c\/li\u003e\n\u003cli\u003eA loud humming or chattering sound is heard from the contactor.\u003c\/li\u003e\n\u003cli\u003eVisible signs of heat damage, arcing, or pitting on the contacts.\u003c\/li\u003e\n\u003cli\u003eThe unit runs continuously and will not shut off.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all electrical power to the HVAC unit at the breaker and service disconnect before servicing.\u003c\/li\u003e\n\u003cli\u003eUse a multimeter to confirm that no voltage is present.\u003c\/li\u003e\n\u003cli\u003eDocument or photograph the original wire locations before disconnecting.\u003c\/li\u003e\n\u003cli\u003eEnsure all electrical connections are clean and securely fastened to the terminals.\u003c\/li\u003e\n\u003cli\u003eVerify that the replacement contactor's specifications match the system's requirements for amperage and coil voltage.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45772993593533,"sku":"AZ00463918","price":14.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00463918_1.jpg?v=1764140968"},{"product_id":"2-pole-contactor-30-amp-24vac-coil","title":"2 Pole Contactor 30 Amp 24VAC Coil","description":"\u003ch2\u003e2 Pole Contactor 30 Amp 24VAC Coil\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePoles: 2\u003c\/li\u003e\n\u003cli\u003eCoil Voltage: 24 VAC\u003c\/li\u003e\n\u003cli\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eInductive Rating: 30 Amps (FLA)\u003c\/li\u003e\n\u003cli\u003eResistive Rating: 40 Amps\u003c\/li\u003e\n\u003cli\u003eTerminals: Box Lugs and Quick Connects\u003c\/li\u003e\n\u003cli\u003eConstruction: Encased coil, silver alloy contacts, and copper terminals\u003c\/li\u003e\n\u003cli\u003eMounting: Universal base plate for simple installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCopeland: 90-244\u003c\/li\u003e\n\u003cli\u003ePackard: C230A\u003c\/li\u003e\n\u003cli\u003eFirstChoice: EC30224-EW\u003c\/li\u003e\n\u003cli\u003eElecDirect: TCDP302B6\u003c\/li\u003e\n\u003cli\u003eCatalog Number: Y4624\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eApplication: Definite purpose contactor for residential and commercial HVAC systems, including air conditioners and heat pumps.\u003c\/li\u003e\n\u003cli\u003eDesigned as a universal replacement for original equipment manufacturer (OEM) contactors with matching electrical specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor condenser unit fails to start or runs intermittently.\u003c\/li\u003e\n\u003cli\u003eLoud humming or buzzing sound from the control panel.\u003c\/li\u003e\n\u003cli\u003eVisible pitting, burn marks, or arcing on contact points.\u003c\/li\u003e\n\u003cli\u003eContacts are physically stuck or welded together, causing the unit to run continuously.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all electrical power to the HVAC unit at the circuit breaker and service disconnect before servicing.\u003c\/li\u003e\n\u003cli\u003eUse a multimeter to confirm that no voltage is present.\u003c\/li\u003e\n\u003cli\u003ePhotograph or label wires before disconnecting the old contactor to ensure correct re-wiring.\u003c\/li\u003e\n\u003cli\u003eConfirm the new contactor's specifications (voltage, amperage, poles) match the component being replaced.\u003c\/li\u003e\n\u003cli\u003eEnsure all electrical connections are clean and securely fastened to prevent overheating.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45772993626301,"sku":"AZ00115867","price":19.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00115867_1_795ddd55-d67e-44c2-9c6e-9544a16faa3a.jpg?v=1762245902"},{"product_id":"78-throttle-cable-for-gy6-scooters-mopeds-bluestars","title":"78-Inch Throttle Cable for GY6 50cc-150cc Scooter Moped Go-Kart Engines","description":"\u003ch2\u003e78-Inch Throttle Cable for GY6 50cc-150cc Scooter Moped Go-Kart Engines\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExtended 78-inch (198cm) total length specifically designed for long-wheelbase scooters and rear-engine go-karts.\u003c\/li\u003e\n\u003cli\u003eLow-friction inner wire coating to ensure a smooth, responsive \"snap-back\" throttle action.\u003c\/li\u003e\n\u003cli\u003eWeather-resistant outer housing designed to prevent internal corrosion and cable binding in high-humidity environments.\u003c\/li\u003e\n\u003cli\u003eStandard 10mm threaded adjuster at the handlebar end for precise tension calibration.\u003c\/li\u003e\n\u003cli\u003eUniversal \"noodle\" curved guide at the carburetor end for clean routing around engine components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e91520\u003c\/li\u003e\n\u003cli\u003e92207\u003c\/li\u003e\n\u003cli\u003e92208\u003c\/li\u003e\n\u003cli\u003e92210\u003c\/li\u003e\n\u003cli\u003eTC-GY6-78\u003c\/li\u003e\n\u003cli\u003e139QMB-TC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eEngines:\u003c\/b\u003e GY6 50cc (139QMB), 125cc (152QMI), and 150cc (157QMJ) 4-stroke OHV engines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eScooter Models:\u003c\/b\u003e TaoTao (Lancer, BWS, ATM50), Jonway, Roketa, Ice Bear, Wolf RX50, Peace Sports, and Future Champion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOther Vehicles:\u003c\/b\u003e 150cc Go-Karts, Dune Buggies, Pit Bikes, and Dongfang Mopeds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe throttle grip feels heavy, \"crunchy,\" or fails to return to the idle position automatically.\u003c\/li\u003e\n\u003cli\u003eVisible fraying or broken steel strands at the barrel ends or junction points.\u003c\/li\u003e\n\u003cli\u003eThe engine RPMs increase unintentionally when the handlebars are turned to the left or right.\u003c\/li\u003e\n\u003cli\u003eThe protective outer casing is melted, kinked, or cracked, exposing the inner wire to debris.\u003c\/li\u003e\n\u003cli\u003eExcessive \"slop\" in the throttle grip that cannot be removed using the inline adjuster.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eFollow Original Routing:\u003c\/b\u003e Route the new cable exactly along the path of the old one to avoid high-heat areas like the exhaust manifold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAvoid Tight Bends:\u003c\/b\u003e Ensure there are no sharp angles in the cable path, as these will cause internal friction and premature failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSet Free Play:\u003c\/b\u003e Adjust the threaded barrel so there is approximately 2mm to 4mm of free play in the throttle grip before the carburetor butterfly begins to open.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLubrication:\u003c\/b\u003e Apply a small amount of silicone-based cable lubricant to the inner wire before final assembly to ensure long-term smooth operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSafety Check:\u003c\/b\u003e With the engine off, turn the handlebars fully from lock to lock and verify the throttle stays in the closed position throughout the entire range of motion.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45772996116669,"sku":"AZ00213808","price":9.11,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00145367_1_5d3da7bb-640b-4ca9-97e0-4d3a76cf890c.jpg?v=1762245842"},{"product_id":"cjx21210-3-pole-contactor-25-amp-220vac-coil","title":"CJX2-1210 3 Pole Contactor 25 Amp 220 VAC Coil - Fits Relays, Air Conditioner, Heat Pump","description":"\u003ch2\u003eCJX2-1210 3 Pole Contactor 25 Amp 220 VAC Coil\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Conductivity Silver Alloy Contacts:\u003c\/strong\u003e Engineered with premium silver-cadmium oxide contact points that provide superior electrical conductivity and arc resistance, ensuring a long service life even under high-frequency switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame-Retardant Industrial Housing:\u003c\/strong\u003e Encased in a high-strength, heat-stabilized thermoset plastic that resists tracking and melting, providing a safe electrical barrier for high-voltage industrial and HVAC applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision 220V Electromagnetic Coil:\u003c\/strong\u003e Features a high-quality copper-wound induction coil designed for stable pull-in and release voltages, reducing the \"chatter\" and humming often found in lower-quality contactors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated 1NO Auxiliary Contact:\u003c\/strong\u003e Equipped with one built-in \"Normally Open\" (10) auxiliary terminal, allowing for the easy integration of indicator lights, interlocking circuits, or feedback signals to a control board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal DIN Rail \u0026amp; Screw Mounting:\u003c\/strong\u003e Designed for maximum installation flexibility, featuring a standard 35mm DIN rail snap-fit base as well as traditional screw-hole mounting for panel-backplate installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCJX2-1210\u003c\/li\u003e\n\u003cli\u003eLC1-D1210\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSchneider:\u003c\/strong\u003e LC1D1210M7\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cstrong\u003eChint:\u003c\/strong\u003e NC1-1210\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eABB:\u003c\/strong\u003e AF12-30-10\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cp\u003eThis 3-pole contactor is a universal heavy-duty switch used for controlling motors, heating elements, and lighting loads. Common applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC Systems:\u003c\/strong\u003e Acts as the primary power switch for air conditioner compressors and heat pump outdoor units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Motor Control:\u003c\/strong\u003e Suitable for three-phase motors up to 5.5kW (at 380\/400V) or single-phase motors in pumps, fans, and conveyors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Equipment:\u003c\/strong\u003e Used to switch high-amperage resistive heating elements in industrial ovens and water heaters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLighting Arrays:\u003c\/strong\u003e Capable of managing large banks of commercial high-intensity discharge (HID) or LED lighting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e Ensure your control circuit provides \u003cstrong\u003e220V\/230V AC\u003c\/strong\u003e to the coil (Terminals A1 and A2). This unit will not operate on 24V or 120V control circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoud Buzzing or Humming:\u003c\/strong\u003e Indicates debris inside the magnetic core or a failing shaded pole, which can lead to overheating and coil burnout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\"Chattering\" Contacts:\u003c\/strong\u003e The contactor opens and closes rapidly when energized, often caused by a weakened internal spring or a failing electromagnetic coil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisible Carbon Buildup:\u003c\/strong\u003e \"Pitting\" or black charring on the contact points suggests the silver coating has worn away, causing high resistance and potential fire hazards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurnt Smell:\u003c\/strong\u003e An acrid, metallic odor coming from the contactor usually indicates the internal coil has melted or the plastic housing is overheating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit Won't Close:\u003c\/strong\u003e The coil receives power (A1\/A2), but the plunger does not pull in, indicating a break in the coil winding.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First:\u003c\/strong\u003e You MUST disconnect the main power supply. Contactors manage high-voltage and high-current circuits that can cause severe injury or equipment damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoil Wiring (A1\/A2):\u003c\/strong\u003e Connect your 220V control wires to the A1 and A2 terminals. It does not matter which wire goes to which A-terminal as it is a non-polarized AC coil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine vs. Load:\u003c\/strong\u003e Connect your incoming power to the top terminals (L1, L2, L3) and your motor or device wires to the bottom terminals (T1, T2, T3).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck Terminal Torque:\u003c\/strong\u003e Ensure all screw terminals are tightened firmly. Loose connections are the #1 cause of contactor failure and \"arcing\" heat damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Use:\u003c\/strong\u003e If your system uses a \"Run\" light or a status sensor, connect those low-current wires to the NO (13\/14) terminals on the right side of the unit.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45772996640957,"sku":"AZ00191345","price":14.39,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00191345_1_347d9d6f-8dc5-46bf-bd26-312838abbb4b.jpg?v=1765275994"},{"product_id":"2pack-ssr40aa-solid-state-relay","title":"SSR-40AA AC to AC Solid State Relay - 2 Pack","description":"\u003ch2\u003eSSR-40AA Solid State Relay\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel: SSR-40AA\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eType: Single Phase AC-to-AC Solid State Relay\u003c\/li\u003e\n\u003cli\u003eLoad Current: 40A\u003c\/li\u003e\n\u003cli\u003eInput Voltage Range: 70-280V AC\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Range: 24-480V AC\u003c\/li\u003e\n\u003cli\u003eSwitching Method: Zero-Crossing\u003c\/li\u003e\n\u003cli\u003eFeatures a built-in LED status indicator\u003c\/li\u003e\n\u003cli\u003eDesigned with a metal base plate for thermal management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSSR-40AA\u003c\/li\u003e\n\u003cli\u003eSSR 40AA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGeneral-purpose component for applications requiring AC load switching.\u003c\/li\u003e\n\u003cli\u003eCommonly used in temperature control systems (PID), industrial automation, heating elements, lighting controls, and other machinery.\u003c\/li\u003e\n\u003cli\u003eDesigned for use with resistive loads.\u003c\/li\u003e\n\u003cli\u003eEnsure your application's voltage and current requirements fall within this relay's specified operating range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe connected load does not turn on when control voltage is applied.\u003c\/li\u003e\n\u003cli\u003eThe connected load remains on permanently, even with no control voltage.\u003c\/li\u003e\n\u003cli\u003eOperation is intermittent or unreliable.\u003c\/li\u003e\n\u003cli\u003eVisible signs of overheating, charring, or physical damage to the relay casing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eA heat sink is required for loads exceeding 10A to prevent overheating.\u003c\/li\u003e\n\u003cli\u003eApply a thin layer of thermal compound between the relay's metal base and the heat sink for optimal heat transfer.\u003c\/li\u003e\n\u003cli\u003eEnsure all terminal connections are secure to prevent arcing.\u003c\/li\u003e\n\u003cli\u003eUse appropriately sized wiring to handle the intended load current.\u003c\/li\u003e\n\u003cli\u003eVerify correct wiring for input (control) and output (load) terminals before applying power.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45844235157693,"sku":"AZ00230688","price":17.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00236087_1_15610535-624c-40dc-9226-5402002afc39.jpg?v=1762245740"},{"product_id":"2-pcs-ssr40dd-solid-state-relay","title":"SSR-40DD DC to DC Solid State Relay - 2 Pack","description":"\u003ch2\u003eSSR-40DD Solid State Relay\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompletely Silent Operation:\u003c\/strong\u003e Unlike traditional mechanical relays, this Solid State Relay (SSR) uses internal semiconductors to switch the load. This means zero clicking noises, zero mechanical wear, and zero electrical arcing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpto-Isolated Safety:\u003c\/strong\u003e Features internal optical isolation between the low-voltage control circuit and the high-voltage load circuit, completely protecting your sensitive microcontrollers or PLCs from high-voltage spikes and feedback.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Speed Switching:\u003c\/strong\u003e Capable of turning on and off infinitely faster than a mechanical switch, making it highly suitable for precise PID temperature control and PWM (Pulse Width Modulation) applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Epoxy Housing:\u003c\/strong\u003e The internal components are heavily potted in a flame-retardant industrial epoxy resin, making the relay highly resistant to severe vibration, moisture, and dust.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective Safety Cover:\u003c\/strong\u003e Includes a clear, flip-up polycarbonate safety shield over the screw terminals to prevent accidental short circuits or dangerous physical contact with live DC wires.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Type:\u003c\/strong\u003e DC-to-DC (DC Input controls a DC Load).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e SSR-40DD.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Input Voltage:\u003c\/strong\u003e 3V to 32V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Output Voltage:\u003c\/strong\u003e 5V to 200V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Load Current:\u003c\/strong\u003e 40 Amps (Requires adequate heatsink).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Voltage Drop:\u003c\/strong\u003e ≤ 1.5V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eUniversal Compatibility \u0026amp; Applications\u003c\/h3\u003e\n\u003cp\u003eThis heavy-duty DC solid state relay is a staple for custom power control and industrial automation:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeated Beds (3D Printing):\u003c\/strong\u003e Frequently used to safely route heavy DC current from a power supply to a 3D printer's heated bed, bypassing the fragile motherboard MOSFETs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolar \u0026amp; Battery Systems:\u003c\/strong\u003e Excellent for custom charge controllers, battery disconnects, or switching heavy DC solar panel arrays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Motor Control:\u003c\/strong\u003e Used to switch high-torque brushed DC motors in robotics, CNC machines, or industrial actuators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Power LED Arrays:\u003c\/strong\u003e Perfect for PWM dimming of large 12V or 24V LED lighting banks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Use or Upgrade\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Relay Failure:\u003c\/strong\u003e If your standard mechanical relay has welded its contacts shut from high-current arcing, upgrading to an SSR completely eliminates this failure point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Stuck \"On\":\u003c\/strong\u003e When an SSR fails, it almost always fails in the \"closed\" (always on) position. If your heated bed or motor refuses to shut off even when the control signal is removed, the internal triac has burned out.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Speeds:\u003c\/strong\u003e If your project requires a switch to toggle multiple times per second (like a PID temperature loop), a mechanical relay will physically break in a few days. An SSR is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeatsink is MANDATORY (\u003c\/strong\u003e\u003cstrong\u003eCRITICAL):\u003c\/strong\u003e SSRs generate significant heat. If you are drawing more than 10 Amps continuously, you \u003cstrong\u003emust\u003c\/strong\u003e mount this relay to an aluminum heatsink. Pushing 40A without a heatsink will literally melt the relay and cause a fire.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Paste:\u003c\/strong\u003e Always apply a thin, even layer of thermal compound (PC processor paste) between the metal bottom of the relay and the aluminum heatsink for proper heat transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrict DC Polarity:\u003c\/strong\u003e Unlike AC relays, DC relays are strictly polarized. You must carefully observe the Positive (+) and Negative (-) markings on both the Input (control) and Output (load) sides. Wiring the load backward will destroy the relay instantly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Derating (\u003c\/strong\u003e\u003cstrong\u003ePRO TIP):\u003c\/strong\u003e For inductive loads (like heavy DC motors with magnetic coils), the starting current spikes massively. It is highly recommended to derate the relay and only run inductive loads at 50% of the maximum rating (i.e., keep continuous motor loads under 20A for a 40A relay).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45844235747517,"sku":"AZ00112969","price":19.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00115897_1_539f453c-f4e3-4cf0-ab59-a8d9f5eadc5d.jpg?v=1762245732"},{"product_id":"82in-throttle-cable","title":"82in Throttle Cable","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\n\u003ch3\u003eProduct Parameters\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Length:\u003c\/strong\u003e 2080 mm (82 inches)\u003cbr\u003e\n(Please verify all measurements and compatibility with your vehicle model prior to purchase.)\u003c\/p\u003e\n\n\u003ch3\u003eFit Models\u003c\/h3\u003e\n\u003cp\u003eThis 82-inch throttle cable is specifically engineered for use with:\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e150cc and 250cc Hammerhead models (part numbers 6.000.034 and 6.000.232)\u003c\/li\u003e\n    \u003cli\u003eCarter American Sportworks\u003c\/li\u003e\n    \u003cli\u003eKazuma\u003c\/li\u003e\n    \u003cli\u003eRoketa\u003c\/li\u003e\n    \u003cli\u003eSunl\u003c\/li\u003e\n    \u003cli\u003eJCL go-karts equipped with 150cc and 250cc engines\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSmooth Vehicle Acceleration:\u003c\/strong\u003e The 82-inch throttle cable provides a secure connection between the accelerator pedal and throttle body, ensuring a responsive and consistent pedal feel for an enhanced driving experience.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSymptoms of Wear:\u003c\/strong\u003e Be alert for signs indicating potential issues, such as:\n        \u003cul\u003e\n            \u003cli\u003eDifficulty controlling engine or erratic idle\u003c\/li\u003e\n            \u003cli\u003eThrottle sticking during operation\u003c\/li\u003e\n            \u003cli\u003eFrayed or damaged cable\u003c\/li\u003e\n            \u003cli\u003eBinding or stretching of cable\u003c\/li\u003e\n        \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSuperior Quality Construction:\u003c\/strong\u003e Crafted from high-strength stainless steel coil wire, this throttle cable offers exceptional wear resistance and stable conductivity, ensuring reliable engine performance. The cable is encased in a thick, high-insulated PVC wire harness cover, providing protection against tearing and degradation caused by environmental factors.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLifetime Protection Guarantee:\u003c\/strong\u003e Enjoy peace of mind with our 100% lifetime protection policy, which covers any defects or issues that may arise, ensuring long-lasting performance and reliability.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45844235780285,"sku":"AZ00125845","price":9.59,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00125845_1_a48f0fb8-1f56-461e-bee6-338f8c8ad248.jpg?v=1762245731"},{"product_id":"212cc-throttle-control-kit","title":"212cc Throttle Control Kit","description":"\u003ch2\u003e212cc Throttle Control Kit\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides direct throttle cable connection to the carburetor.\u003c\/li\u003e\n\u003cli\u003eEnables retention of the stock fuel tank on the engine.\u003c\/li\u003e\n\u003cli\u003eDesigned for ungoverned engines using stock-style carburetors.\u003c\/li\u003e\n\u003cli\u003eComplete kit includes throttle base, control arm, linkage rod, and springs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAftermarket replacement kit for stock throttle and governor linkage systems.\u003c\/li\u003e\n\u003cli\u003eUsed for performance upgrades and custom small engine applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePredator Engines: 212cc (Hemi and Non-Hemi), 196cc, 224cc\u003c\/li\u003e\n\u003cli\u003eHonda Engines: GX160 (5.5hp), GX200 (6.5hp)\u003c\/li\u003e\n\u003cli\u003eClone Engines: Fits most 196cc and 212cc clone engines based on the Honda GX platform.\u003c\/li\u003e\n\u003cli\u003eCommon Applications: Go-karts, mini bikes, and custom small engine projects.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWhen removing the internal governor for improved engine performance.\u003c\/li\u003e\n\u003cli\u003eTo achieve more direct and responsive throttle control.\u003c\/li\u003e\n\u003cli\u003eIf original factory linkage is damaged, bent, or missing.\u003c\/li\u003e\n\u003cli\u003eDuring an engine swap or installation into a new chassis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThis kit is intended for use on engines where the governor has been removed.\u003c\/li\u003e\n\u003cli\u003eEnsure the throttle return spring is correctly installed for safe operation.\u003c\/li\u003e\n\u003cli\u003eVerify smooth, bind-free movement of the linkage and carburetor throttle plate before starting the engine.\u003c\/li\u003e\n\u003cli\u003eSome installations may require re-using the original recoil housing bolts for mounting.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45844235813053,"sku":"AZ00252534","price":11.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00252534_1_f1d74661-59e4-4a0d-82b6-dd596981a837.jpg?v=1762245730"},{"product_id":"solid-state-relay-ssr40da-dc-to-ac-input-332vdc-output-24380vac-40a","title":"SSR-40DA DC to AC Solid State Relay - 3 Pack","description":"\u003ch2\u003eSSR-40DA Solid State Relay\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel: SSR-40DA\u003c\/li\u003e\n\u003cli\u003eType: Single-phase solid state relay\u003c\/li\u003e\n\u003cli\u003eControl Input Voltage: 3-32V DC\u003c\/li\u003e\n\u003cli\u003eLoad Output Voltage: 24-380V AC\u003c\/li\u003e\n\u003cli\u003eMaximum Load Current: 40A\u003c\/li\u003e\n\u003cli\u003eSwitching Method: Electronic, for fast response and long service life\u003c\/li\u003e\n\u003cli\u003eConstruction: Aluminum heat-dissipating base plate with screw terminals\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSSR-40DA\u003c\/li\u003e\n\u003cli\u003eReplaces solid state relays with matching electrical specifications (3-32V DC control, 24-380V AC load, up to 40A)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for various AC load switching applications including PID temperature controllers, industrial automation, HVAC systems, and motor controls.\u003c\/li\u003e\n\u003cli\u003eCompatible with microcontrollers and PLCs that provide a 3-32V DC output signal.\u003c\/li\u003e\n\u003cli\u003eA heat sink is required for loads exceeding 10A to prevent thermal damage and ensure rated performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRelay fails to activate the load when a control signal is present.\u003c\/li\u003e\n\u003cli\u003eRelay remains stuck in the \"ON\" position, keeping the load powered without a control signal.\u003c\/li\u003e\n\u003cli\u003eUnit overheats under normal operating conditions (with an appropriate heat sink).\u003c\/li\u003e\n\u003cli\u003eVisible damage, such as a cracked housing or corroded terminals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all power sources before installation or servicing.\u003c\/li\u003e\n\u003cli\u003eMount the relay on a correctly sized heat sink, especially when switching loads greater than 10A.\u003c\/li\u003e\n\u003cli\u003eApply a thin layer of thermal paste between the relay's metal base and the heat sink for optimal heat transfer.\u003c\/li\u003e\n\u003cli\u003eConnect control (input) and load (output) wiring to the correct terminals as marked on the device.\u003c\/li\u003e\n\u003cli\u003eEnsure all wire connections are secure to prevent arcing and overheating.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45870607990973,"sku":"AZ00161344","price":19.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00222448_1_38505446-88aa-481e-9472-bc3a151f8e92.jpg?v=1772012809"},{"product_id":"ps417-25070cd00a-oil-pressure-sensor-switch","title":"PS417 25070-CD00A Oil Pressure Sensor Switch","description":"\u003ch2\u003ePS417 25070-CD00A Oil Pressure Sensor Switch\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect-fit replacement for proper installation\u003c\/li\u003e\n\u003cli\u003eAccurately measures engine oil pressure\u003c\/li\u003e\n\u003cli\u003eSends signal to the dashboard oil pressure gauge or warning light\u003c\/li\u003e\n\u003cli\u003eEngineered to meet original equipment specifications for performance and reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e25070-CD00A\u003c\/li\u003e\n\u003cli\u003e25070-CD000\u003c\/li\u003e\n\u003cli\u003ePS417\u003c\/li\u003e\n\u003cli\u003e1S6896\u003c\/li\u003e\n\u003cli\u003e42CP16-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eInfiniti:\u003c\/b\u003e QX56 (2004-2009)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eNissan:\u003c\/b\u003e 350Z (2003-2009), Altima (2005-2006), Armada (2005-2008), Frontier, GT-R (2009-2010), Pathfinder, Sentra, Titan, Xterra\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOil pressure warning light is illuminated or flashing\u003c\/li\u003e\n\u003cli\u003eDashboard oil pressure gauge provides inaccurate or erratic readings\u003c\/li\u003e\n\u003cli\u003eVisible oil leak from the sensor housing\u003c\/li\u003e\n\u003cli\u003eDiagnostic trouble codes related to the oil pressure circuit are present\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect the negative battery terminal before beginning work.\u003c\/li\u003e\n\u003cli\u003eLocate the old sensor on the engine; its position varies by model.\u003c\/li\u003e\n\u003cli\u003eUse the correct size deep socket for removal and installation.\u003c\/li\u003e\n\u003cli\u003eEnsure threads on the engine block are clean before installing the new part.\u003c\/li\u003e\n\u003cli\u003eTorque the new sensor to the manufacturer's specified value to prevent leaks or damage.\u003c\/li\u003e\n\u003cli\u003eEnsure the electrical connector is clean and attaches securely.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45870608875709,"sku":"AZ00249291","price":14.29,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00700454_1.jpg?v=1764141386"},{"product_id":"premium-universal-bike-brake-cable-set-include-front-and-rear-brake-cables","title":"Universal Bike Brake Cable Set - Include Front \u0026 Rear Brake Cables \u0026 Housing - Complete Brake Replacement Kit","description":"\u003ch2\u003ePremium Universal Bike Brake Cable Set - Include Front and Rear Brake Cables \u0026amp; Housing - Complete Brake Replacement Kit for Mountain, Trail, Cruisers, MTB, City Bikes\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplete Set: Includes two brake cables, one continuous length of brake housing, ferrules, and cable end caps for a full front and rear brake replacement.\u003c\/li\u003e\n\u003cli\u003eCable Specifications: 2000mm length x 1.5mm diameter. Designed to be cut to size for front or rear application.\u003c\/li\u003e\n\u003cli\u003eDurable Construction: Inner cables are constructed from high-tensile, corrosion-resistant steel strands for strength and longevity.\u003c\/li\u003e\n\u003cli\u003eHigh-Performance Housing: 5mm diameter housing features a low-friction polymer liner to ensure smooth, responsive braking action.\u003c\/li\u003e\n\u003cli\u003eUniversal Nipple End: Equipped with a standard barrel end for mountain bike (MTB) and flat-bar style brake levers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides a universal replacement for standard mechanical brake cable and housing systems on most major bicycle brands.\u003c\/li\u003e\n\u003cli\u003eServes as a direct-fit alternative to generic or OEM replacement kits such as Shimano, SRAM, and other standard brake systems.\u003c\/li\u003e\n\u003cli\u003eSuitable for upgrading or replacing original equipment cables on a wide variety of bicycles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBike Types: Designed for Mountain Bikes (MTB), Trail Bikes, Cruisers, City Bikes, and other bicycles using flat-bar or upright handlebars.\u003c\/li\u003e\n\u003cli\u003eBrake Systems: Compatible with mechanical brake systems, including V-brakes, cantilever brakes, caliper brakes, and mechanical disc brakes.\u003c\/li\u003e\n\u003cli\u003eLever Type: Fits standard MTB-style brake levers that require a barrel-shaped cable end nipple. Not compatible with road bike brake levers requiring a pear-shaped nipple.\u003c\/li\u003e\n\u003cli\u003eCut-to-Fit Design: Both the inner cable and the outer housing are provided in long lengths to be cut for a precise fit on various frame sizes and handlebar configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBraking performance is diminished, spongy, or inconsistent.\u003c\/li\u003e\n\u003cli\u003eInner cable shows signs of fraying, corrosion, or kinks.\u003c\/li\u003e\n\u003cli\u003eBrake lever action feels stiff, gritty, or does not return smoothly.\u003c\/li\u003e\n\u003cli\u003eOuter housing is cracked, compressed, or bent at sharp angles.\u003c\/li\u003e\n\u003cli\u003eRegular maintenance interval, typically every 1-2 years depending on use and riding conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUse a dedicated cable and housing cutter to ensure a clean, square cut. A poor cut can cause friction and fraying.\u003c\/li\u003e\n\u003cli\u003eEnsure ferrules are installed on each end of a cut housing section before inserting the cable.\u003c\/li\u003e\n\u003cli\u003eMeasure the new housing against the old housing segments to achieve the correct lengths for your frame.\u003c\/li\u003e\n\u003cli\u003eAfter installation, pull the brake lever firmly multiple times to bed in the housing and pre-stretch the cable, then re-adjust tension at the caliper and barrel adjuster.\u003c\/li\u003e\n\u003cli\u003eAlways install a cable end cap and crimp it securely to prevent the cut cable from unraveling.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45870608941245,"sku":"AZ00687056","price":18.82,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00687056_1.jpg?v=1764141502"},{"product_id":"2-pole-contactor-40-amp-240vac-coil","title":"2 Pole Contactor 40 Amp 240 VAC Coil - Fits Relays, Air Conditioner, Heat Pump, Refrigeration Systems","description":"\u003ch2\u003e2 Pole Contactor 40 Amp 240VAC Coil\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConfiguration: 2 Pole, Single Throw (DPST)\u003c\/li\u003e\n\u003cli\u003eElectrical Rating: 40 Amp Full Load Amps (FLA)\u003c\/li\u003e\n\u003cli\u003eCoil Voltage: 240VAC\u003c\/li\u003e\n\u003cli\u003eContacts constructed from a silver alloy for high conductivity and resistance to oxidation.\u003c\/li\u003e\n\u003cli\u003eUL Certified (File E476929)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect replacement for contactors with matching 40A, 2-pole, and 240VAC coil specifications.\u003c\/li\u003e\n\u003cli\u003eCompatible with parts such as Appli Parts APAC-240240 and others from various manufacturers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for use in residential and commercial HVAC systems.\u003c\/li\u003e\n\u003cli\u003eSuitable for:\u003c\/li\u003e\n\u003cli\u003eAir Conditioners\u003c\/li\u003e\n\u003cli\u003eHeat Pumps\u003c\/li\u003e\n\u003cli\u003eRefrigeration Systems\u003c\/li\u003e\n\u003cli\u003eElectric Motors\u003c\/li\u003e\n\u003cli\u003eWater Pumps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor condenser unit will not start.\u003c\/li\u003e\n\u003cli\u003eAC unit hums but the compressor or fan does not engage.\u003c\/li\u003e\n\u003cli\u003eVisible signs of wear, such as burned, pitted, or corroded contacts.\u003c\/li\u003e\n\u003cli\u003eThe system runs continuously and will not shut off.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all electrical power to the unit at the breaker and service disconnect before starting work.\u003c\/li\u003e\n\u003cli\u003eVerify the amperage and coil voltage of the original contactor to ensure a match.\u003c\/li\u003e\n\u003cli\u003ePhotograph or label the wire connections before disconnecting the old part to ensure correct wiring.\u003c\/li\u003e\n\u003cli\u003eEnsure the new contactor is mounted securely in the control panel.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":46041559826621,"sku":"AZ00214515","price":28.66,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00214515_1_5c6ca9a7-1e36-4530-a343-04ffadb1c994.jpg?v=1765275943"},{"product_id":"2-pole-contactor-40-amp-24vac-coil","title":"2 Pole Contactor 40 Amp 24VAC Coil Exact Fit with Relays, Air Conditioner, Heat Pump, Refrigeration Systems","description":"\u003ch2\u003e2-Pole Contactor (40 Amp, 24VAC Coil)\u003c\/h2\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Duty 40A Rating:\u003c\/strong\u003e Designed to handle the high inductive loads of large A\/C compressors and heat pump motors, providing a significantly longer service life than standard 30A units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-Pole Configuration:\u003c\/strong\u003e Breaks both legs of a 240V circuit simultaneously, ensuring total power isolation to the equipment when the thermostat is not calling for cooling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24V Low-Voltage Coil:\u003c\/strong\u003e Engineered for an \"Exact Fit\" with standard residential HVAC control systems, allowing the thermostat to trigger the high-voltage circuit safely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSilver Alloy Contacts:\u003c\/strong\u003e Features premium oxide-resistant contact points to prevent welding and pitting, maintaining high conductivity through thousands of cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDust-Shielded Design:\u003c\/strong\u003e Built with a protective housing to prevent insects and debris from interfering with the mechanical plunger or the electrical contacts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eC240A\u003c\/li\u003e\n\u003cli\u003eDP40242\u003c\/li\u003e\n\u003cli\u003eCTR02574\u003c\/li\u003e\n\u003cli\u003eCONT2P040024V\u003c\/li\u003e\n\u003cli\u003eHCCY2XU04AA303\u003c\/li\u003e\n\u003cli\u003eMars 17421\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cp\u003eThis contactor is a universal replacement for most residential and light commercial HVAC units. Key compatible brands include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Conditioners \u0026amp; Heat Pumps:\u003c\/strong\u003e Fits units from Carrier, Bryant, Payne, Rheem, Ruud, Goodman, Amana, Lennox, Trane, and American Standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigeration Systems:\u003c\/strong\u003e Compatible with walk-in coolers and commercial refrigeration compressors requiring a 24V control signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Compatibility:\u003c\/strong\u003e The coil requires 24VAC; the load terminals are rated for use with 120V, 208V, or 240V AC power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumming or Chattering:\u003c\/strong\u003e A loud buzzing noise often indicates that the 24V coil is weak or that the contacts are dirty and unable to pull in fully.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondenser Won't Start:\u003c\/strong\u003e The indoor fan is running and the thermostat is set to \"Cool,\" but the outdoor unit is silent, suggesting a failed contactor coil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurned or Pitted Contacts:\u003c\/strong\u003e Visible blackening or \"soot\" around the metal contact points, which can cause the compressor to overheat or fail to start.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWelded Contacts:\u003c\/strong\u003e The outdoor fan and compressor continue to run even when the thermostat is turned off, indicating the contacts have melted together.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnt\/Insect Infestation:\u003c\/strong\u003e Small insects (like \"crazy ants\") are attracted to the electrical field and can get crushed between the contacts, preventing a solid connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First:\u003c\/strong\u003e Turn off the power at both the outdoor disconnect box and the main indoor breaker panel. Verify with a multimeter that no voltage is present before touching the wires.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLabel Your Wires:\u003c\/strong\u003e Take a photo of the old contactor before disconnecting. Mark the \"Line\" (power in), \"Load\" (to compressor), and \"Control\" (24V wires from the thermostat) clearly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure Terminals:\u003c\/strong\u003e Ensure all lug screws are tightened firmly. A loose connection on a 40A circuit will generate extreme heat and can melt the wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrientation:\u003c\/strong\u003e While contactors can often be mounted in various positions, mounting it vertically (as originally designed) helps prevent dust and moisture from settling on the moving plunger.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the Coil:\u003c\/strong\u003e Ensure your system is 24V. If you install a 24V contactor into a system that uses a 120V or 240V control circuit, the coil will burn out instantly.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":46497319157949,"sku":"AZ00105092","price":16.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00105092_1.jpg?v=1765959298"},{"product_id":"cjx21210-ac-contactor-3-pole-25-amp-220vac-coil-normally-open","title":"CJX2-1210 AC Contactor 3 Pole 25 Amp 220VAC Coil - Normally Open, Replacement for Air Conditioner, Heat Pump \u0026 Refrigeration Systems","description":"\u003ch2\u003eCJX2-1210 AC Contactor (3-Pole, 25A, 220VAC Coil)\u003c\/h2\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Capacity Switching:\u003c\/strong\u003e Rated for up to 25 Amps, making it ideal for managing the high-current startup loads of compressors and fan motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-Pole Design:\u003c\/strong\u003e Features three sets of Normally Open (N.O.) power contacts to switch multiple phases or legs of power simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e220VAC Operating Coil:\u003c\/strong\u003e Designed to be triggered by standard 220V control signals commonly found in industrial and heavy-duty HVAC\/R systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Auxiliary Contact:\u003c\/strong\u003e Includes one built-in Normally Open (1NO) auxiliary contact for signaling, status feedback, or interlocking with other control circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail \u0026amp; Screw Mount:\u003c\/strong\u003e Dual mounting options provide flexibility for installation in standard electrical control boxes or custom enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e CJX2-1210\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3-Pole + 1NO (Normally Open) Auxiliary\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current (AC-3):\u003c\/strong\u003e 12A (General) \/ 25A Max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoil Voltage:\u003c\/strong\u003e 220V AC, 50\/60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Voltage (Ui):\u003c\/strong\u003e 660V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Flame-retardant outer shell with high-conductivity silver alloy contacts for long electrical life.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility \u0026amp; Applications\u003c\/h3\u003e\n\u003cp\u003eThis contactor is a versatile replacement for motor control and heating systems across various brands. Common applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC\/R:\u003c\/strong\u003e Controlling outdoor condenser units, heat pump compressors, and large refrigeration evaporators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Motors:\u003c\/strong\u003e Starting and stopping 3-phase AC motors in conveyor systems, pumps, and fans.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLighting \u0026amp; Heating:\u003c\/strong\u003e Switching high-wattage resistance heaters or large commercial lighting arrays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement:\u003c\/strong\u003e Fits many systems requiring LC1-D1210 or equivalent 220V 12A\/25A contactors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChattering or Humming:\u003c\/strong\u003e A loud buzzing noise indicates the internal solenoid coil is weak or the contacts are dirty and vibrating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurnt Contacts:\u003c\/strong\u003e Visible blackening or pitting on the contact points, which can cause the motor to \"single-phase\" and burn out.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStuck in \"On\" or \"Off\":\u003c\/strong\u003e Contacts have welded shut due to an electrical surge, or the return spring has failed, preventing the circuit from opening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurnt Coil Smell:\u003c\/strong\u003e An acrid odor or visible melting near the A1\/A2 terminals indicates the electromagnetic coil has shorted out.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First:\u003c\/strong\u003e Turn off all power to the equipment at the main breaker. Verify that no voltage is present with a multimeter before touching terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Labeling:\u003c\/strong\u003e Label your wires before disconnecting. \u003cstrong\u003eL1, L2, L3\u003c\/strong\u003e are for incoming power; \u003cstrong\u003eT1, T2, T3\u003c\/strong\u003e are for the load (motor); and \u003cstrong\u003eA1, A2\u003c\/strong\u003e are for the 220V control coil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTight Connections:\u003c\/strong\u003e Ensure all screw terminals are tightened firmly. Loose connections create high resistance, which leads to heat and premature failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Use the DIN rail clip for a clean snap-fit or secure the unit to the backplate using the mounting holes to prevent vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e After installation, ensure the manual override plunger moves freely and isn't obstructed by any stray wire strands.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":46497320239293,"sku":"AZ00270239","price":11.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00270239_1.jpg?v=1764142092"}],"url":"https:\/\/bluestarspartstrend.com\/collections\/control.oembed","provider":"BlueStars Parts","version":"1.0","type":"link"}