{"title":"House - Furnace Parts","description":"\u003cp data-start=\"129\" data-end=\"382\"\u003eFind high-quality furnace parts at BlueStars. From igniters to filters, we offer reliable, OEM-compatible parts to keep your furnace running efficiently. Enjoy fast shipping, affordable prices, and top-notch performance with every part you purchase.\u003c\/p\u003e","products":[{"product_id":"0130f00010-furnace-flame-sensor","title":"0130F00010 Furnace Flame Sensor Replacement - For Goodman Amana Furnaces","description":"\u003ch2\u003e0130F00010 Furnace Flame Sensor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDetects flame in Hot Surface Ignition (HSI) systems for safe furnace operation.\u003c\/li\u003e\n\u003cli\u003eConstructed with a metal sensing rod and an alumina ceramic insulator.\u003c\/li\u003e\n\u003cli\u003eDesigned as a direct-fit replacement for specified furnace models.\u003c\/li\u003e\n\u003cli\u003eMounts to the burner assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e0130F00010\u003c\/li\u003e\n\u003cli\u003eB1172606\u003c\/li\u003e\n\u003cli\u003eB11726-06\u003c\/li\u003e\n\u003cli\u003e20488501\u003c\/li\u003e\n\u003cli\u003eTJFLS013\u003c\/li\u003e\n\u003cli\u003e2645136\u003c\/li\u003e\n\u003cli\u003eAP4513976\u003c\/li\u003e\n\u003cli\u003eAP6326767\u003c\/li\u003e\n\u003cli\u003eL38035\u003c\/li\u003e\n\u003cli\u003eACS90453BXA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor use in specific furnace models from Goodman, Amana, Daikin, and Janitrol.\u003c\/li\u003e\n\u003cli\u003eConfirm fitment by referencing your equipment's service manual or the original part number.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace burners ignite but shut off after a few seconds.\u003c\/li\u003e\n\u003cli\u003eMain burners fail to remain lit after the ignition sequence.\u003c\/li\u003e\n\u003cli\u003eVisible carbon buildup, corrosion, or cracking on the sensor rod or ceramic insulator.\u003c\/li\u003e\n\u003cli\u003eControl board displays a fault code related to flame sense failure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all electrical power and shut off the gas supply to the furnace before installation.\u003c\/li\u003e\n\u003cli\u003eThe sensor is typically secured by a single screw on the burner bracket.\u003c\/li\u003e\n\u003cli\u003ePosition the sensor rod so it will be directly in the path of the burner flame.\u003c\/li\u003e\n\u003cli\u003eHandle the new sensor carefully and avoid touching the ceramic insulator with bare hands.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45367044145341,"sku":"AZ0869491","price":11.3,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ0869491_1_65c77976-c0ad-4df5-9aca-8143343b1602.jpg?v=1765276036"},{"product_id":"0130f00010-flame-sensor-5pack","title":"0130F00010 Furnace Flame Sensor Replacement - For Goodman Amana Furnaces - 5 Pack","description":"\u003ch2\u003e0130F00010 Flame Sensor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSenses the presence of flame in the burner assembly.\u003c\/li\u003e\n\u003cli\u003eDirect replacement part designed for proper fit and function.\u003c\/li\u003e\n\u003cli\u003eEnables consistent furnace operation by sending a signal to the control board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e0130F00010\u003c\/li\u003e\n\u003cli\u003eB1172606\u003c\/li\u003e\n\u003cli\u003eB11726-06\u003c\/li\u003e\n\u003cli\u003e20488501\u003c\/li\u003e\n\u003cli\u003eTJFLS013\u003c\/li\u003e\n\u003cli\u003e2645136\u003c\/li\u003e\n\u003cli\u003eAP4513976\u003c\/li\u003e\n\u003cli\u003eAP6326767\u003c\/li\u003e\n\u003cli\u003eL38035\u003c\/li\u003e\n\u003cli\u003eACS90453BXA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for use with various furnace models from Goodman, Amana, and Daikin.\u003c\/li\u003e\n\u003cli\u003eFits specific models including GMHB and GDHB series.\u003c\/li\u003e\n\u003cli\u003eVerify compatibility by checking the part number on your original sensor or in your furnace's service manual.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace burners ignite for a few seconds and then shut off.\u003c\/li\u003e\n\u003cli\u003eHeating cycle starts but does not complete.\u003c\/li\u003e\n\u003cli\u003eDiagnostic codes indicate a flame sense or ignition failure.\u003c\/li\u003e\n\u003cli\u003eExisting sensor rod is corroded, cracked, or heavily coated in carbon buildup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAlways disconnect all electrical power to the furnace before servicing.\u003c\/li\u003e\n\u003cli\u003eLocate the sensor near the rear burner, typically secured with a single 1\/4 inch hex screw.\u003c\/li\u003e\n\u003cli\u003eRemove the screw and wire to release the old sensor.\u003c\/li\u003e\n\u003cli\u003eInstall the new sensor, ensuring the porcelain insulator is intact and the rod does not ground against any metal.\u003c\/li\u003e\n\u003cli\u003eSecurely fasten the screw and reconnect the wire.\u003c\/li\u003e\n\u003cli\u003eRestore power and test the furnace through a full heating cycle.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45367044374717,"sku":"AZ00251427","price":16.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00251427_1_b667fb63-c1fb-4303-bba2-3e5df729618f.jpg?v=1765276024"},{"product_id":"0130f00010-flame-sensor-3pack","title":"0130F00010 Furnace Flame Sensor Replacement - For Goodman Amana Furnaces - 3 Pack","description":"\u003ch2\u003e0130F00010 Flame Sensor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDetects flame in gas furnace burner assemblies for safe operation.\u003c\/li\u003e\n\u003cli\u003eDirect-fit replacement part for gas HVAC systems.\u003c\/li\u003e\n\u003cli\u003eTotal length: 3.8 inches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e0130F00010\u003c\/li\u003e\n\u003cli\u003eB1172606\u003c\/li\u003e\n\u003cli\u003eB11726-06\u003c\/li\u003e\n\u003cli\u003e20488501\u003c\/li\u003e\n\u003cli\u003eTJFLS013\u003c\/li\u003e\n\u003cli\u003e2645136\u003c\/li\u003e\n\u003cli\u003eAP4513976\u003c\/li\u003e\n\u003cli\u003eAP6326767\u003c\/li\u003e\n\u003cli\u003eL38035\u003c\/li\u003e\n\u003cli\u003eACS90453BXA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for many Goodman and Amana brand gas furnaces.\u003c\/li\u003e\n\u003cli\u003eCompatible with models including ACS90453BXA.\u003c\/li\u003e\n\u003cli\u003eAlways verify fitment using your furnace model number and original part number.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace ignites but shuts off after only a few seconds.\u003c\/li\u003e\n\u003cli\u003eHeavy carbon buildup or corrosion on the existing sensor rod.\u003c\/li\u003e\n\u003cli\u003eVisible cracks in the porcelain insulator.\u003c\/li\u003e\n\u003cli\u003eHVAC system indicates a flame sensor error code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAlways disconnect power to the furnace before servicing.\u003c\/li\u003e\n\u003cli\u003eThe sensor is typically secured to the burner assembly with a single screw.\u003c\/li\u003e\n\u003cli\u003eHandle the new sensor by its porcelain base to avoid contaminating the metal rod with skin oils.\u003c\/li\u003e\n\u003cli\u003eEnsure the rod is positioned directly in the flame path for proper operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45367044604093,"sku":"AZ56899442","price":14.12,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00144545_1_465c235f-2fd2-48ec-a30b-acb31235f8ce.jpg?v=1762246880"},{"product_id":"622354301-furnace-flame-sensor-4pack","title":"62-23543-01 Furnace Flame Sensor Replacement - For Rheem, Ruud, WeatherKing, Thermal Zone, DuroGuard Furnace - 4 Pack","description":"\u003ch2\u003e62-23543-01 Furnace Flame Sensor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitors burner flame to ensure safe furnace operation.\u003c\/li\u003e\n\u003cli\u003eSignals the control system to shut off the gas valve if no flame is detected.\u003c\/li\u003e\n\u003cli\u003eConstructed from durable stainless steel and a ceramic insulator.\u003c\/li\u003e\n\u003cli\u003eFeatures a 90-degree bend for proper positioning in the flame path.\u003c\/li\u003e\n\u003cli\u003ePackage contains four individual flame sensors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e62-23543-01\u003c\/li\u003e\n\u003cli\u003e62-23543-02\u003c\/li\u003e\n\u003cli\u003e62-23543-03\u003c\/li\u003e\n\u003cli\u003e62-23543-04\u003c\/li\u003e\n\u003cli\u003ePSE-RH8\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for select furnace models from Rheem, Ruud, and Weatherking.\u003c\/li\u003e\n\u003cli\u003eVerify compatibility by matching the part number with your existing sensor or service manual.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace ignites but shuts down after a few seconds.\u003c\/li\u003e\n\u003cli\u003eVisible corrosion or carbon buildup on the sensor rod that cannot be cleaned.\u003c\/li\u003e\n\u003cli\u003eFurnace control board displays a diagnostic error code for flame sensor failure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect electrical power and shut off the gas supply to the furnace before beginning installation.\u003c\/li\u003e\n\u003cli\u003eHandle the new sensor by its ceramic base to avoid transferring oils from your skin to the metal rod.\u003c\/li\u003e\n\u003cli\u003eEnsure the sensor rod is correctly positioned to be engulfed by the burner flame for accurate sensing.\u003c\/li\u003e\n\u003cli\u003eConfirm all connections are secure before restoring power and gas.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45367044735165,"sku":"AZ00172374","price":22.29,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00172374_1_17de29e4-657f-4738-83b3-18ee86c55d47.jpg?v=1762246879"},{"product_id":"2pack-622354301-furnace-flame-sensor","title":"62-23543-01 Furnace Flame Sensor Replacement - For Rheem, Ruud, WeatherKing, Thermal Zone, DuroGuard Furnace - 2 Pack","description":"\u003ch2\u003e62-23543-01 Furnace Flame Sensor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSensing Rod Material: Metal alloy\u003c\/li\u003e\n\u003cli\u003eInsulator Material: Alumina ceramic\u003c\/li\u003e\n\u003cli\u003eTermination: 1\/4 inch male quick connect\u003c\/li\u003e\n\u003cli\u003eTotal Length (Mounting Flange to Sensor Tip): 2-1\/2 inches\u003c\/li\u003e\n\u003cli\u003eSensor Offset Length: 1-9\/16 inches\u003c\/li\u003e\n\u003cli\u003eSensor Offset Angle: 90 degrees\u003c\/li\u003e\n\u003cli\u003eFunction: Detects burner flame for safe furnace operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e62-23543-01\u003c\/li\u003e\n\u003cli\u003e62-23543-02\u003c\/li\u003e\n\u003cli\u003e62-23543-03\u003c\/li\u003e\n\u003cli\u003e62-23543-04\u003c\/li\u003e\n\u003cli\u003ePSE-RH8\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for Hot Surface Ignition (HSI) and spark ignition systems\u003c\/li\u003e\n\u003cli\u003eCompatible with gas furnaces from brands including Rheem, Ruud, WeatherKing, Thermal Zone, and DuroGuard\u003c\/li\u003e\n\u003cli\u003eMounts directly on the burner assembly or adjacent to the igniter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace ignites but shuts down after a few seconds\u003c\/li\u003e\n\u003cli\u003eFurnace control board indicates a flame sensor fault or error code\u003c\/li\u003e\n\u003cli\u003eVisible carbon buildup, corrosion, or damage to the existing sensor rod\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect electrical power and shut off the gas supply to the furnace before servicing.\u003c\/li\u003e\n\u003cli\u003eAvoid touching the metal sensor rod with bare hands; skin oils can cause premature failure. Handle with clean gloves or a cloth.\u003c\/li\u003e\n\u003cli\u003eHandle the ceramic insulator carefully to prevent cracks or damage.\u003c\/li\u003e\n\u003cli\u003eEnsure the sensor rod is properly positioned in the path of the flame for accurate detection.\u003c\/li\u003e\n\u003cli\u003eConfirm all electrical connections are secure before restoring power.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45367044964541,"sku":"AZ00675604","price":13.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00675604_1_5f890f62-ab42-42f1-9702-273aadee8cfa.jpg?v=1762246878"},{"product_id":"69w43-furnace-flame-sensor","title":"69W43 Furnace Flame Sensor - Exact ForLennox, Armstrong \u0026 Ducane Furnaces","description":"\u003ch2\u003e69W43 Furnace Flame Sensor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSensing rod detects flame presence for furnace operation\u003c\/li\u003e\n\u003cli\u003eAngled probe design\u003c\/li\u003e\n\u003cli\u003eOverall width: 4-5\/8 in\u003c\/li\u003e\n\u003cli\u003eFeatures a 3\/16 in male terminal for connection\u003c\/li\u003e\n\u003cli\u003eDurable construction for long service life\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e69W43\u003c\/li\u003e\n\u003cli\u003e69W4301\u003c\/li\u003e\n\u003cli\u003eLB-74940B\u003c\/li\u003e\n\u003cli\u003eLB74940B\u003c\/li\u003e\n\u003cli\u003e102431-02\u003c\/li\u003e\n\u003cli\u003e790-801A1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect replacement for specific furnace models from brands including:\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eArmstrong\u003c\/li\u003e\n\u003cli\u003eDucane\u003c\/li\u003e\n\u003cli\u003eLennox\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eVerify compatibility with your furnace model number prior to purchase.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace starts the ignition sequence but shuts off after a few seconds.\u003c\/li\u003e\n\u003cli\u003eFurnace control board indicates a flame sensor fault code.\u003c\/li\u003e\n\u003cli\u003eVisible carbon buildup, corrosion, or damage on the existing sensor rod.\u003c\/li\u003e\n\u003cli\u003eThe ceramic insulator is cracked or broken.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect electrical power to the furnace unit before servicing.\u003c\/li\u003e\n\u003cli\u003eAvoid touching the metal rod with bare hands; handle by the ceramic base.\u003c\/li\u003e\n\u003cli\u003eEnsure the sensor is correctly positioned in the pilot or main burner flame.\u003c\/li\u003e\n\u003cli\u003eConfirm the mounting screw and wire are securely fastened.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45367045095613,"sku":"AZ1382207","price":19.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00143111_1_b521424f-6bd1-487b-90c1-22ac01d88c48.jpg?v=1762246877"},{"product_id":"lh680014-lh680534-furnace-flame-sensor","title":"LH680014 LH680534 Furnace Flame Sensor - For Carrier Bryant Payne Day \u0026 Night Furnaces","description":"\u003ch2\u003eLH680014 \/ LH680534 Furnace Flame Sensor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitors the burner flame to ensure safe furnace operation\u003c\/li\u003e\n\u003cli\u003eSignals the furnace control board to shut off the gas valve if a flame is not detected\u003c\/li\u003e\n\u003cli\u003eDurable construction for long service life\u003c\/li\u003e\n\u003cli\u003eTwo-piece design for installation flexibility; connect pieces prior to installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eLH680014\u003c\/li\u003e\n\u003cli\u003eLH680534\u003c\/li\u003e\n\u003cli\u003eLH680012\u003c\/li\u003e\n\u003cli\u003eLH33WZ511\u003c\/li\u003e\n\u003cli\u003eLH33WZ515\u003c\/li\u003e\n\u003cli\u003eLH33WZ517\u003c\/li\u003e\n\u003cli\u003ePFS014\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFits specific furnace models from brands including Carrier, Bryant, Payne, and Day \u0026amp; Night\u003c\/li\u003e\n\u003cli\u003eCommonly used in models such as: 340MAV, 345MAV, 350MAV, 355MAV, 373LAV, 58MXA, and others\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace burners ignite but shut off after a few seconds\u003c\/li\u003e\n\u003cli\u003eFurnace fails to ignite, resulting in a system lockout\u003c\/li\u003e\n\u003cli\u003eVisible corrosion or carbon buildup on the sensor rod that cannot be cleaned\u003c\/li\u003e\n\u003cli\u003eDiagnostic error codes indicate a flame sensor fault\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect electrical power and shut off the gas supply to the furnace before servicing\u003c\/li\u003e\n\u003cli\u003eHandle the new sensor by its ceramic base to avoid contaminating the metal rod\u003c\/li\u003e\n\u003cli\u003eEnsure the two pieces of the sensor are securely connected before installation\u003c\/li\u003e\n\u003cli\u003eConfirm the sensor is properly positioned in the path of the pilot or main burner flame\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45367045456061,"sku":"AZ0715462","price":15.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ0715462_1.jpg?v=1765335658"},{"product_id":"472286101-limit-switches-l350-furnace-bimetal-thermostat","title":"47-22861-01 Limit Switches L350 Furnace Bimetal Thermostat Switch - 250V\/10A","description":"\u003ch2\u003e47-22861-01 Furnace Flame Rollout Limit Switch L350\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBimetal disc design for temperature sensing\u003c\/li\u003e\n\u003cli\u003eProvides high-limit temperature protection\u003c\/li\u003e\n\u003cli\u003eFixed temperature cutout at 350°F (L350)\u003c\/li\u003e\n\u003cli\u003eSingle Pole, Single Throw (SPST) switch configuration\u003c\/li\u003e\n\u003cli\u003eDesigned for use in residential and light commercial HVAC systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e47-22861-01\u003c\/li\u003e\n\u003cli\u003e47-22861-01K\u003c\/li\u003e\n\u003cli\u003e47-22861-02\u003c\/li\u003e\n\u003cli\u003eL350F\u003c\/li\u003e\n\u003cli\u003eSRL350\u003c\/li\u003e\n\u003cli\u003e350F\u003c\/li\u003e\n\u003cli\u003e36TX16\u003c\/li\u003e\n\u003cli\u003e47-100241-01\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect replacement for Rheem furnaces requiring part number 47-22861-01\u003c\/li\u003e\n\u003cli\u003eFits various HVAC systems that specify a 350°F SPST high-limit switch\u003c\/li\u003e\n\u003cli\u003eVerify compatibility by checking the part number and temperature rating on the original switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace blower runs continuously after the heating cycle stops\u003c\/li\u003e\n\u003cli\u003eHeating cycle stops prematurely and restarts frequently (short cycling)\u003c\/li\u003e\n\u003cli\u003eFurnace fails to ignite or produce heat due to an open limit circuit\u003c\/li\u003e\n\u003cli\u003eThe original switch fails a continuity test with a multimeter when at room temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all electrical power to the furnace before beginning installation\u003c\/li\u003e\n\u003cli\u003eLocate the existing limit switch, typically mounted on the furnace plenum or near the heat exchanger\u003c\/li\u003e\n\u003cli\u003eNote the wire connections before removing the old switch\u003c\/li\u003e\n\u003cli\u003eRemove mounting screws and wires from the original switch\u003c\/li\u003e\n\u003cli\u003eInstall the new switch, ensuring it is securely fastened\u003c\/li\u003e\n\u003cli\u003eReconnect wires to the terminals on the new switch\u003c\/li\u003e\n\u003cli\u003eRestore power and run the furnace through a complete heating cycle to verify correct operation\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45369804456125,"sku":"AZ00193376","price":8.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00151811_1_a5838009-250b-4e2d-85ef-8330b1274610.jpg?v=1762246313"},{"product_id":"02537499000-gas-furnace-flame-sensor","title":"025-37499-000 Gas Furnace Flame Sensor - For York Luxaire Coleman Gas Furnace","description":"\u003ch2\u003e025-37499-000 Gas Furnace Flame Sensor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCrucial safety component for gas-fired appliances\u003c\/li\u003e\n\u003cli\u003eDetects burner flame to ensure safe ignition and operation\u003c\/li\u003e\n\u003cli\u003eConstructed from high-quality, corrosion-resistant materials for longevity\u003c\/li\u003e\n\u003cli\u003eDesigned as a direct-fit replacement for the original equipment manufacturer part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e025-37499-000\u003c\/li\u003e\n\u003cli\u003eS1-025-37499-000\u003c\/li\u003e\n\u003cli\u003eS1-02537499000\u003c\/li\u003e\n\u003cli\u003e02537499000\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFits specific furnace models from York, Luxaire, and Coleman\u003c\/li\u003e\n\u003cli\u003eCompatible with various models including the TG9S series\u003c\/li\u003e\n\u003cli\u003eConfirmed fit for models such as ACS90453BXA, ACS90703BXA, and ACS90704CXA\u003c\/li\u003e\n\u003cli\u003ePlease verify fitment by checking your furnace's service manual or original part number\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace burners ignite briefly then shut down after a few seconds\u003c\/li\u003e\n\u003cli\u003eVisible carbon buildup, corrosion, or damage on the sensor rod\u003c\/li\u003e\n\u003cli\u003eDiagnostic fault codes from the furnace control board indicate a flame sensor issue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect electrical power and shut off the gas supply to the furnace before beginning installation\u003c\/li\u003e\n\u003cli\u003eThe sensor is typically located in the path of the burner assembly, opposite the igniter\u003c\/li\u003e\n\u003cli\u003eHandle the new sensor by its ceramic base to avoid transferring skin oils to the metal rod\u003c\/li\u003e\n\u003cli\u003eEnsure the new sensor is securely mounted and the electrical connection is firm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45772996673725,"sku":"AZ19339427","price":12.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00129371_1_fafa2dde-141b-4174-a14d-6941afd83175.jpg?v=1762245829"},{"product_id":"2-packs-02537499000-gas-furnace-flame-sensor","title":"025-37499-000 Gas Furnace Flame Sensor - For York Luxaire Coleman Gas Furnace - 2 Pack","description":"\u003ch2\u003e025-37499-000 Gas Furnace Flame Sensor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDetects the presence of flame in the burner assembly.\u003c\/li\u003e\n\u003cli\u003eSignals the furnace control to shut off the gas valve if no flame is detected, preventing unburnt gas accumulation.\u003c\/li\u003e\n\u003cli\u003eConstructed from durable, high-temperature resistant materials for longevity.\u003c\/li\u003e\n\u003cli\u003eDirect-fit replacement for specified models.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e025-37499-000\u003c\/li\u003e\n\u003cli\u003eS1-025-37499-000\u003c\/li\u003e\n\u003cli\u003eS1-02537499000\u003c\/li\u003e\n\u003cli\u003e02537499000\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFits select gas furnace models from brands including York, Luxaire, and Coleman.\u003c\/li\u003e\n\u003cli\u003eConfirmed fit for models such as CP9C080812MP12C, CP9C080B12MP11, CP9C080B12MP12C, CP9C080C16MP12C, ACS90453BXA, and ACS90703BXA.\u003c\/li\u003e\n\u003cli\u003eVerify compatibility by checking your furnace's original part number or service manual.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace ignites but shuts down after a few seconds.\u003c\/li\u003e\n\u003cli\u003eMain burners fail to remain lit during the heating cycle.\u003c\/li\u003e\n\u003cli\u003eVisible carbon buildup, corrosion, or pitting on the sensor's metal rod.\u003c\/li\u003e\n\u003cli\u003eCracked or damaged porcelain insulator.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all electrical power to the furnace before servicing.\u003c\/li\u003e\n\u003cli\u003eLocate the flame sensor, typically mounted with a single screw near the last burner in the ignition sequence.\u003c\/li\u003e\n\u003cli\u003eRemove the mounting screw and disconnect the single wire.\u003c\/li\u003e\n\u003cli\u003eHandle the new sensor by its ceramic base; avoid touching the metal rod with bare hands as skin oils can damage it.\u003c\/li\u003e\n\u003cli\u003eInstall the new sensor, ensuring it is correctly positioned in the flame path.\u003c\/li\u003e\n\u003cli\u003eReconnect the wire, restore power, and test the furnace for proper operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45772996837565,"sku":"AZ00366216","price":16.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00802070_1_61406df9-521e-4a16-88f5-3e8d492785ef.jpg?v=1765276021"},{"product_id":"69w43-furnace-flame-sensor-2pack","title":"69W43 Furnace Flame Sensor - For Lennox, Armstrong \u0026 Ducane Furnaces - Replaces 69W4301 LB-74940B LB74940B - 2 Pack","description":"\u003ch2\u003e69W43 Furnace Flame Sensor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDetects burner flame to enable safe and continuous furnace operation.\u003c\/li\u003e\n\u003cli\u003eConstructed with a durable cermet insulator and a corrosion-resistant sensing rod.\u003c\/li\u003e\n\u003cli\u003eAngled probe design for direct replacement and optimal positioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e69W43\u003c\/li\u003e\n\u003cli\u003e69W4301\u003c\/li\u003e\n\u003cli\u003eLB-74940B\u003c\/li\u003e\n\u003cli\u003eLB74940B\u003c\/li\u003e\n\u003cli\u003e102431-02\u003c\/li\u003e\n\u003cli\u003e790-801A1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned as a direct replacement part for specific furnace models from:\u003c\/li\u003e\n\u003cli\u003eLennox\u003c\/li\u003e\n\u003cli\u003eDucane\u003c\/li\u003e\n\u003cli\u003eArmstrong\u003c\/li\u003e\n\u003cli\u003eNote: Always confirm compatibility by checking your equipment's service manual and part number.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace ignites but shuts down after a few seconds.\u003c\/li\u003e\n\u003cli\u003eBurner flame will not stay lit.\u003c\/li\u003e\n\u003cli\u003eVisible damage, such as a cracked porcelain insulator on the existing sensor.\u003c\/li\u003e\n\u003cli\u003eHeavy carbon buildup or corrosion on the sensor rod that cleaning does not resolve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all electrical power to the furnace unit before beginning installation.\u003c\/li\u003e\n\u003cli\u003eHandle the new sensor by the porcelain base to avoid contaminating the metal rod with skin oils.\u003c\/li\u003e\n\u003cli\u003eEnsure the sensor rod is properly positioned to be enveloped by the burner flame during operation.\u003c\/li\u003e\n\u003cli\u003eInspect the connecting wire for damage and ensure a secure connection.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45772996870333,"sku":"AZ00209924","price":17.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00109547_1_d49f1405-5dd1-4901-b7e1-e2b8f164fe5a.jpg?v=1762245822"},{"product_id":"52w29-furnace-flame-sensor","title":"52W29 Furnace Flame Sensor Replacement - For Lennox Armstrong \u0026 Ducane Furnaces","description":"\u003ch2\u003e52W29 Furnace Flame Sensor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitors burner flame to ensure safe furnace operation.\u003c\/li\u003e\n\u003cli\u003eDirect replacement for the original manufacturer's part.\u003c\/li\u003e\n\u003cli\u003eOverall length: 5.25 inches.\u003c\/li\u003e\n\u003cli\u003eSensing rod length: 2.75 inches.\u003c\/li\u003e\n\u003cli\u003eConstructed with a high-temperature resistant metal rod and ceramic insulator.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e52W29\u003c\/li\u003e\n\u003cli\u003e52W2901\u003c\/li\u003e\n\u003cli\u003e31L71\u003c\/li\u003e\n\u003cli\u003e31L7101\u003c\/li\u003e\n\u003cli\u003eLB-74940A\u003c\/li\u003e\n\u003cli\u003e28PV41\u003c\/li\u003e\n\u003cli\u003e903600\u003c\/li\u003e\n\u003cli\u003eFLS52W29\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFits specific gas furnace models from Lennox, Armstrong, and Ducane.\u003c\/li\u003e\n\u003cli\u003eCompatible with furnace series including G40, G41, G50, G51, G60, G61, and G71.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace ignites but shuts down after a few seconds.\u003c\/li\u003e\n\u003cli\u003eFurnace fails to heat consistently or at all.\u003c\/li\u003e\n\u003cli\u003eThe sensor rod is visibly corroded, cracked, or has heavy carbon buildup that cannot be cleaned.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all electrical power to the furnace before servicing.\u003c\/li\u003e\n\u003cli\u003eHandle the component by its metal bracket to avoid damaging the ceramic insulator.\u003c\/li\u003e\n\u003cli\u003eEnsure the sensor rod is properly positioned in the flame path for correct operation.\u003c\/li\u003e\n\u003cli\u003eVerify a secure wire connection before restoring power.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45844230701245,"sku":"AZ1624905","price":9.93,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ1624905_1_d5459a7d-54cf-4dc4-8390-539d4a043286.jpg?v=1762245777"},{"product_id":"0130f00010-furnace-flame-sensor-2pack","title":"0130F00010 Furnace Flame Sensor Replacement - For Goodman Amana Furnaces - 2 Pack","description":"\u003ch2\u003e0130F00010 Furnace Flame Sensor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDetects flame presence in gas furnaces for safe ignition and operation.\u003c\/li\u003e\n\u003cli\u003eConstructed from high-quality, corrosion-resistant metal and a durable ceramic insulator.\u003c\/li\u003e\n\u003cli\u003eDirect replacement for specified part numbers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e0130F00010\u003c\/li\u003e\n\u003cli\u003eB1172606\u003c\/li\u003e\n\u003cli\u003eB11726-06\u003c\/li\u003e\n\u003cli\u003e20488501\u003c\/li\u003e\n\u003cli\u003eTJFLS013\u003c\/li\u003e\n\u003cli\u003e2645136\u003c\/li\u003e\n\u003cli\u003eAP4513976\u003c\/li\u003e\n\u003cli\u003eAP6326767\u003c\/li\u003e\n\u003cli\u003eL38035\u003c\/li\u003e\n\u003cli\u003eACS90453BXA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for select gas furnace models from brands including:\u003c\/li\u003e\n\u003cli\u003eAmana\u003c\/li\u003e\n\u003cli\u003eDaikin\u003c\/li\u003e\n\u003cli\u003eGoodman\u003c\/li\u003e\n\u003cli\u003eJanitrol\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace shuts down shortly after ignition.\u003c\/li\u003e\n\u003cli\u003eMain burner fails to stay lit.\u003c\/li\u003e\n\u003cli\u003eFrequent or intermittent system cycling.\u003c\/li\u003e\n\u003cli\u003eVisible corrosion, carbon buildup, or damage to the existing sensor rod.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all electrical power to the furnace before servicing.\u003c\/li\u003e\n\u003cli\u003eHandle the new sensor by its ceramic base to avoid transferring oils from your skin to the metal rod.\u003c\/li\u003e\n\u003cli\u003eEnsure the rod is properly positioned to be engulfed by the burner flame for accurate sensing.\u003c\/li\u003e\n\u003cli\u003eConfirm the wire connection is secure after installation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45844232995005,"sku":"AZ00170228","price":8.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00170228_1_f655834a-c0d6-47f3-b021-399cb14124c2.jpg?v=1762245776"},{"product_id":"632625-furnace-ignitor","title":"632625 Furnace Ignitor - For Nordyne Intertherm Broan Miller Furnaces","description":"\u003ch2\u003e632625 Hot Surface Furnace Ignitor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect replacement hot surface ignitor designed to safely and consistently ignite the gas burner assembly in residential heating systems.\u003c\/li\u003e\n\u003cli\u003eConstructed from high-density, temperature-resistant materials to withstand rapid heating cycles and prevent thermal shock cracking.\u003c\/li\u003e\n\u003cli\u003eIncludes a factory-crimped, high-temperature ceramic wire harness and plug block for a secure, plug-and-play electrical connection.\u003c\/li\u003e\n\u003cli\u003eEngineered to exact original equipment resistance specifications for optimal heat-up timing and immediate gas ignition.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e632625\u003c\/li\u003e\n\u003cli\u003e632625R\u003c\/li\u003e\n\u003cli\u003e1016290S\u003c\/li\u003e\n\u003cli\u003eN1016290S\u003c\/li\u003e\n\u003cli\u003eCMF95 M7RL\u003c\/li\u003e\n\u003cli\u003eCMF95\/M7\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with select residential and mobile home gas furnaces.\u003c\/li\u003e\n\u003cli\u003eFits specific furnace units manufactured by Nordyne, Intertherm, Broan, and Miller.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe furnace draft inducer motor runs and the gas valve opens, but the burners fail to light, causing the system to lock out.\u003c\/li\u003e\n\u003cli\u003eThe ignitor heating element displays visible hairline cracks, structural breakage, or heavy white oxidation spots.\u003c\/li\u003e\n\u003cli\u003eThe furnace diagnostic control board continuously flashes an error code indicating an ignition failure.\u003c\/li\u003e\n\u003cli\u003eTesting the ignitor wire leads with a digital multimeter displays infinite resistance (an open circuit).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurn off the main electrical breaker to the furnace and shut off the incoming gas supply valve prior to servicing the unit.\u003c\/li\u003e\n\u003cli\u003eNever touch the dark heating element of the new ignitor with your bare hands; skin oils will create hot spots and cause the part to shatter when energized.\u003c\/li\u003e\n\u003cli\u003eCarefully insert the new ignitor through the burner box mounting bracket, as the element is extremely brittle and will snap if bumped against the metal housing.\u003c\/li\u003e\n\u003cli\u003eRoute the wire harness exactly as it was originally placed, ensuring it is secured well away from the open burner flames and sharp sheet metal edges.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45844236861629,"sku":"AZ00152656","price":44.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00152656_1_45ea28e2-0b9b-436e-b781-1f3e5f97b7f5.jpg?v=1762245700"},{"product_id":"20162904-furnace-primary-limit-switch-150f-to-110f","title":"20162904 Furnace Primary Limit Switch (150°F to 110°F) - For Goodman Furnace","description":"\u003ch2\u003e20162904 Furnace Primary Limit Switch\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature Range: Opens at 150°F (65.5°C) and closes at 110°F (43.3°C).\u003c\/li\u003e\n\u003cli\u003eFunction: Monitors plenum temperature and automatically shuts down the furnace if it exceeds the high limit, preventing overheating.\u003c\/li\u003e\n\u003cli\u003eConstruction: Made from aluminum alloy and thermoplastic materials for durability and reliable conductivity.\u003c\/li\u003e\n\u003cli\u003eType: Primary high-limit temperature control switch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e20162904\u003c\/li\u003e\n\u003cli\u003e20162904S\u003c\/li\u003e\n\u003cli\u003eL40-524\u003c\/li\u003e\n\u003cli\u003eL40524\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for use in various Goodman brand furnaces.\u003c\/li\u003e\n\u003cli\u003eVerify the part number in your appliance's service manual to ensure proper fitment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe furnace cycles on and off frequently without reaching the set temperature.\u003c\/li\u003e\n\u003cli\u003eThe indoor blower motor runs continuously.\u003c\/li\u003e\n\u003cli\u003eThe furnace fails to ignite or produce heat.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all electrical power to the furnace before servicing.\u003c\/li\u003e\n\u003cli\u003eConfirm the temperature ratings of the replacement switch match the original part.\u003c\/li\u003e\n\u003cli\u003eNote the position of the electrical connections before removing the old switch.\u003c\/li\u003e\n\u003cli\u003eInstallation by a qualified service technician is recommended.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45844237254845,"sku":"AZ00211289","price":29.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00211289_1_f29a5e05-166e-4352-9ffd-3f3df9f5c493.jpg?v=1762245686"},{"product_id":"l21020f-furnace-primary-limit-switch-40f-to-180f","title":"L210-20F Furnace Primary Limit Switch (-40°F to 180°F) - For ICP Heil Tempstar Furnaces","description":"\u003ch2\u003eL210-20F Primary Furnace Limit Switch\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCritical safety switch designed to shut down the gas valve and burner circuit if the furnace heat exchanger exceeds maximum safe operating temperatures.\u003c\/li\u003e\n\u003cli\u003eThermal setting calibrated to automatically open the circuit on temperature rise at 210°F and close (reset) at 190°F.\u003c\/li\u003e\n\u003cli\u003eConstructed with a highly responsive bimetallic disc enclosed in a temperature-resistant phenolic housing to prevent heat distortion.\u003c\/li\u003e\n\u003cli\u003eFeatures a flush-mount bracket and standard 1\/4-inch male quick-connect spade terminals for immediate electrical integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eL210-20F\u003c\/li\u003e\n\u003cli\u003e34335001\u003c\/li\u003e\n\u003cli\u003e34335-001\u003c\/li\u003e\n\u003cli\u003eHQ34335001TD\u003c\/li\u003e\n\u003cli\u003e313408\u003c\/li\u003e\n\u003cli\u003e338085-758\u003c\/li\u003e\n\u003cli\u003e47-25349-06\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with select residential gas furnaces manufactured by International Comfort Products (ICP), Heil, and Tempstar.\u003c\/li\u003e\n\u003cli\u003eFits specific furnace models including: GDE050B12A2, GDE050B12G1, and GDE075F16A3.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe furnace continuously short-cycles, shutting off the burner assembly well before reaching the target thermostat temperature.\u003c\/li\u003e\n\u003cli\u003eThe furnace blower fan runs non-stop blowing cold air, indicating the system is locked out due to an open limit circuit.\u003c\/li\u003e\n\u003cli\u003eThe main control board diagnostic LED continuously flashes an error code specifically for an open high-limit switch.\u003c\/li\u003e\n\u003cli\u003eA continuity test performed with a digital multimeter displays infinite resistance (an open circuit) while the switch is resting at room temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurn off the main electrical breaker to the furnace and ensure the unit is completely powered down before opening the service panels.\u003c\/li\u003e\n\u003cli\u003eTake a digital photograph of the existing wire connections to ensure the leads are routed back to the correct spade terminals.\u003c\/li\u003e\n\u003cli\u003eRemove the two hex screws securing the original switch to the heat exchanger bulkhead and carefully pull the component straight out.\u003c\/li\u003e\n\u003cli\u003eAlign the new limit switch flush against the mounting surface and tighten the screws down evenly to prevent bending the mounting plate.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45844237320381,"sku":"AZ00237947","price":18.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00237947_1_ffba4dd1-cc06-4ab4-aee6-48f70fd24800.jpg?v=1762245685"},{"product_id":"87f16-furnace-primary-limit-switch-up-to-140f","title":"87F16 Furnace Primary Limit Switch up to 140°F - For Lennox Furnaces - Replaces 87F16 87F1601 L140-30F 36T01B3","description":"\u003ch2\u003e87F16 Furnace Primary Limit Switch up to 140°F\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrimary high-limit safety control for forced-air furnaces\u003c\/li\u003e\n\u003cli\u003eActivates at a fixed temperature of 140°F (60°C) to prevent overheating\u003c\/li\u003e\n\u003cli\u003eAutomatically resets at 110°F (43°C)\u003c\/li\u003e\n\u003cli\u003eSwitch configuration: SPST (Single Pole, Single Throw), normally open contacts\u003c\/li\u003e\n\u003cli\u003eProbe insertion length: 3 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e87F16\u003c\/li\u003e\n\u003cli\u003e87F1601\u003c\/li\u003e\n\u003cli\u003eL140-30F\u003c\/li\u003e\n\u003cli\u003eL140F-40\u003c\/li\u003e\n\u003cli\u003e36T01B3\u003c\/li\u003e\n\u003cli\u003e42155\u003c\/li\u003e\n\u003cli\u003eA1247\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned as a direct replacement for specific Lennox brand furnaces.\u003c\/li\u003e\n\u003cli\u003eVerify fitment by confirming the part number on your original switch or in your equipment's service manual.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace blower runs continuously after the heating cycle has stopped.\u003c\/li\u003e\n\u003cli\u003eHeating system short-cycles or shuts down prematurely.\u003c\/li\u003e\n\u003cli\u003eFurnace fails to produce heat or ignite the burners.\u003c\/li\u003e\n\u003cli\u003eControl board displays a fault code indicating an open limit switch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all electrical power to the furnace before servicing.\u003c\/li\u003e\n\u003cli\u003eLocate the limit switch, typically mounted on the furnace plenum near the heat exchanger.\u003c\/li\u003e\n\u003cli\u003eNote wire connections before removing the old switch.\u003c\/li\u003e\n\u003cli\u003eInstall the new switch, secure it with the mounting screws, and reconnect the wires to the terminals.\u003c\/li\u003e\n\u003cli\u003eRestore power and test the furnace through a complete heating cycle to ensure proper operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45844237353149,"sku":"AZ00638885","price":27.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00638885_1_0d1a3ffb-8997-4ab8-873f-5f1bd756a87f.jpg?v=1762245684"},{"product_id":"ultra-durable-52w29-furnace-flame-sensor","title":"52W29 Furnace Flame Sensor Replacement - For Lennox Armstrong \u0026 Ducane Furnaces - 2 Pack","description":"\u003ch2\u003e52W29 Furnace Flame Sensor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConstructed with a metal alloy rod and a ceramic insulator for high-temperature durability and conductivity.\u003c\/li\u003e\n\u003cli\u003eDetects burner flame to allow safe and continuous furnace operation.\u003c\/li\u003e\n\u003cli\u003eRod Length: 2-3\/4 inches\u003c\/li\u003e\n\u003cli\u003eConnector Size: 3\/16 inch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e52W29\u003c\/li\u003e\n\u003cli\u003e52W2901\u003c\/li\u003e\n\u003cli\u003e31L71\u003c\/li\u003e\n\u003cli\u003e31L7101\u003c\/li\u003e\n\u003cli\u003eLB-74940A\u003c\/li\u003e\n\u003cli\u003e28PV41\u003c\/li\u003e\n\u003cli\u003e903600\u003c\/li\u003e\n\u003cli\u003eFLS52W29\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect replacement for specific furnace models from Lennox, Armstrong, and Ducane.\u003c\/li\u003e\n\u003cli\u003eConfirmed fit for G40, G41, G50, and G51 series furnaces.\u003c\/li\u003e\n\u003cli\u003eVerify fitment by matching your original part number to the cross-reference list.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe furnace cycles on but the burner shuts off after a few seconds.\u003c\/li\u003e\n\u003cli\u003eThe furnace fails to produce heat or does not stay lit.\u003c\/li\u003e\n\u003cli\u003eThe ceramic insulator on the existing sensor is cracked or broken.\u003c\/li\u003e\n\u003cli\u003eThe metal rod is corroded, covered in carbon buildup, or physically damaged.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all electrical power to the furnace before beginning service.\u003c\/li\u003e\n\u003cli\u003eHandle the new sensor by its ceramic base; avoid touching the metal rod with bare hands as skin oils can cause premature failure.\u003c\/li\u003e\n\u003cli\u003eEnsure the single mounting screw is secure but not overtightened to avoid cracking the ceramic.\u003c\/li\u003e\n\u003cli\u003ePosition the sensor so the metal rod is properly enveloped by the burner flame during operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45844237385917,"sku":"AZ00238981","price":12.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00238981_1_298eafe4-91d1-47ef-92a1-e3306ef1d172.jpg?v=1765275950"},{"product_id":"20261709s-furnace-ignitor-hot-surface","title":"20261709S Furnace Ignitor Hot Surface for Goodman Furnace","description":"\u003ch2\u003e20261709S Furnace Ignitor Hot Surface\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDurable silicon carbide construction for enhanced longevity.\u003c\/li\u003e\n\u003cli\u003eDesigned for rapid heating to ensure reliable and consistent ignition.\u003c\/li\u003e\n\u003cli\u003eDirect replacement for the original component in compatible systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e20261709S\u003c\/li\u003e\n\u003cli\u003e20261709\u003c\/li\u003e\n\u003cli\u003e0130F00014\u003c\/li\u003e\n\u003cli\u003e0130F00014S\u003c\/li\u003e\n\u003cli\u003e594465\u003c\/li\u003e\n\u003cli\u003ePSE-AM17\u003c\/li\u003e\n\u003cli\u003e0230K00001\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEngineered for specific gas-fired furnaces and HVAC units.\u003c\/li\u003e\n\u003cli\u003eCompatible with numerous models from the following brands:\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eGoodman\u003c\/li\u003e\n\u003cli\u003eAmana\u003c\/li\u003e\n\u003cli\u003eJanitrol\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eVerify fitment by matching the part number of your existing ignitor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace blower runs, but the burners fail to light.\u003c\/li\u003e\n\u003cli\u003eThe ignitor does not glow bright orange or red during the ignition sequence.\u003c\/li\u003e\n\u003cli\u003eVisible cracks, breaks, or signs of burnout on the ignitor element.\u003c\/li\u003e\n\u003cli\u003eThe heating system operates intermittently or fails to start reliably.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAlways disconnect electrical power to the furnace before beginning installation.\u003c\/li\u003e\n\u003cli\u003eHandle the new ignitor by its ceramic base only.\u003c\/li\u003e\n\u003cli\u003eDo not touch the dark heating element; oils from your skin can cause premature failure.\u003c\/li\u003e\n\u003cli\u003eEnsure all electrical connections are secure and match the original configuration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45870608154813,"sku":"AZ00150460","price":22.81,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00150460_1_0f884b26-b4ad-4de6-b870-1f058303b52b.jpg?v=1772012802"},{"product_id":"b1401018-furnace-igniter-hot-surface-ignitor-compatible-with-goodman-amana-janitrol-furnace","title":"B1401018 Furnace Igniter Hot Surface Ignitor - For Goodman Amana Janitrol Furnace","description":"\u003ch2\u003eB1401018 Furnace Igniter Hot Surface Ignitor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect replacement hot surface igniter for gas furnaces.\u003c\/li\u003e\n\u003cli\u003eConstructed with a silicon carbide heating element.\u003c\/li\u003e\n\u003cli\u003eFeatures a ceramic base for mounting.\u003c\/li\u003e\n\u003cli\u003eCeramic base dimensions: 1-5\/16 in. wide, 1\/2 in. thick.\u003c\/li\u003e\n\u003cli\u003eDesigned for plug-and-play installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eB1401018\u003c\/li\u003e\n\u003cli\u003eB1401018S\u003c\/li\u003e\n\u003cli\u003eB1401015\u003c\/li\u003e\n\u003cli\u003eB1401015S\u003c\/li\u003e\n\u003cli\u003e271N\u003c\/li\u003e\n\u003cli\u003e41-418\u003c\/li\u003e\n\u003cli\u003eIG418\u003c\/li\u003e\n\u003cli\u003e5H075032B\u003c\/li\u003e\n\u003cli\u003eDS418KX\u003c\/li\u003e\n\u003cli\u003e767A-385\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFits various furnace models from brands including Goodman, Amana, Janitrol, and Modine.\u003c\/li\u003e\n\u003cli\u003eVerify compatibility by matching part numbers from your existing igniter or furnace service manual.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace blower runs, but the burners do not light.\u003c\/li\u003e\n\u003cli\u003eThe igniter fails to glow during the heating cycle.\u003c\/li\u003e\n\u003cli\u003eVisible cracks, burns, or breaks on the igniter element.\u003c\/li\u003e\n\u003cli\u003eIntermittent heating or frequent furnace cycling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all electrical power to the furnace before beginning service.\u003c\/li\u003e\n\u003cli\u003eHandle the new igniter by its ceramic base only. Do not touch the heating element with bare hands, as skin oils can cause premature failure.\u003c\/li\u003e\n\u003cli\u003eVisually compare the new igniter with the old one to ensure correct fitment.\u003c\/li\u003e\n\u003cli\u003eEnsure all wire connections are secure before restoring power.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":46041559597245,"sku":"AZ00238853","price":26.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00238853_1_4cf15d0c-3168-457d-8587-a776618d356c.jpg?v=1765275938"},{"product_id":"525019-rv-furnace-igniter-electrode-230956","title":"525019 230956 RV Furnace Igniter Electrode (Dual-Sense 3-Prong) for Suburban NT-24 NT-30 NT-34 P-40S Series - Fits Serial Numbers Below 920500001","description":"\u003ch2\u003e525019 \/ 230956 RV Furnace Igniter Electrode\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Voltage Spark Delivery:\u003c\/strong\u003e Engineered to provide a consistent, high-intensity electrical arc for rapid ignition of Liquid Propane (LP) gas, ensuring your RV furnace starts reliably in cold weather.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePremium Ceramic Insulation:\u003c\/strong\u003e Features a high-density, heat-stabilized ceramic body that prevents electrical \"arcing\" to the furnace chassis, directing the full spark energy to the burner head.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Probe Sensing Design:\u003c\/strong\u003e Serves a dual purpose by providing the ignition spark and acting as a flame sensor (thermocouple replacement) to signal the control board that a flame has been established.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion-Resistant Alloy:\u003c\/strong\u003e The metal probes are manufactured from a specialized high-temperature alloy designed to resist oxidation and carbon buildup, extending the intervals between maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e525019\u003c\/li\u003e\n\u003cli\u003e230956\u003c\/li\u003e\n\u003cli\u003e525019MC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cp\u003eThis electrode is specifically designed for older Suburban RV furnaces. It is \u003cstrong\u003eNOT\u003c\/strong\u003e compatible with newer furnaces manufactured after May 1992. Key fitment details include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuburban NT Series:\u003c\/strong\u003e Fits \u003cstrong\u003eNT-24\u003c\/strong\u003e, \u003cstrong\u003eNT-30\u003c\/strong\u003e, \u003cstrong\u003eNT-34\u003c\/strong\u003e, and \u003cstrong\u003eNT-40\u003c\/strong\u003e models.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuburban P Series:\u003c\/strong\u003e Compatible with \u003cstrong\u003eP-40S\u003c\/strong\u003e high-capacity models.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Number Constraint:\u003c\/strong\u003e Strictly for units with serial numbers \u003cstrong\u003eBELOW 920500001\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Type:\u003c\/strong\u003e Designed for 12V DC electronic ignition (DSI) systems utilizing the dual-probe configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e If your serial number begins with \"9205\" or higher, you likely need part #525028 instead.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFurnace Clicks but Won't Light:\u003c\/strong\u003e You can hear the rapid \"ticking\" of the igniter, but the gas fails to ignite, often due to a weak spark or dirty probes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition Lockout:\u003c\/strong\u003e The furnace lights for a few seconds and then shuts off. This indicates the flame-sensing side of the electrode is no longer sending a signal to the control board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCracked Ceramic Insulator:\u003c\/strong\u003e Visible hairline cracks in the white ceramic allow the electricity to \"leak\" to the metal frame, preventing a spark at the burner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoot or Carbon Deposits:\u003c\/strong\u003e Heavy black buildup on the metal probes acts as an insulator, blocking the spark and the flame-sensing current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisible Erosion:\u003c\/strong\u003e The metal probes have burned down or become significantly shorter over years of use, making the gap too large to jump.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First (\u003c\/strong\u003e\u003cstrong\u003eCRITICAL):\u003c\/strong\u003e Turn off the main LP gas supply at the tank and disconnect the 12V DC power before removing the furnace access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSet the Spark Gap (\u003c\/strong\u003e\u003cstrong\u003ePRO TIP):\u003c\/strong\u003e Before installing, verify the gap between the two probes is exactly \u003cstrong\u003e1\/8 inch (3.2mm)\u003c\/strong\u003e. If the gap is incorrect, the furnace will fail to ignite.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean the Burner:\u003c\/strong\u003e While the electrode is removed, use a small brush or compressed air to clear any spider webs or rust flakes from the burner slots directly beneath the electrode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the Lead Wire:\u003c\/strong\u003e Inspect the high-voltage wire connecting the electrode to the board. If the insulation is brittle or cracked, it should be replaced along with the electrode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest the Sense:\u003c\/strong\u003e After installation, ensure the furnace stays lit. If it shuts off after 7 seconds, double-check that the electrode is positioned directly in the path of the flame for proper sensing.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":46399101370557,"sku":"AZ00229644","price":25.56,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00229644_1_cc8dbe2e-7d6e-43ac-b3b1-d626cabdd395.jpg?v=1770888417"},{"product_id":"30268-36043-rv-burner-head-and-35100-91788-furnaces-ignitor-electrode-kit-fit","title":"30268 36043 RV Burner Head \u0026 35100 91788 Furnaces Ignitor Electrode Kit for Domestic Atwood Hydro Flame 79 85 AFS \u0026 AFM Series LPG Heaters Fireplaces Atwood RV Furnace","description":"\u003ch2\u003e30268 \u0026amp; 35100 RV Furnace Burner Head and Ignitor Electrode Kit\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Flame Distribution:\u003c\/strong\u003e The 30268 burner head is engineered with accurately spaced combustion slots to provide an even, circular flame pattern, ensuring consistent heat transfer and preventing \"hot spots\" in the furnace chamber.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Temperature Alloy Construction:\u003c\/strong\u003e Manufactured from a heavy-duty, heat-stabilized alloy designed to withstand the rapid thermal cycling of RV heating systems without warping, cracking, or corroding over time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Ceramic Insulation:\u003c\/strong\u003e The 35100 ignitor features a high-grade ceramic insulator that prevents electrical \"leakage\" or arcing to the furnace frame, ensuring the full spark energy is delivered to the gas stream.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Probe Sensing Technology:\u003c\/strong\u003e Designed to provide both a high-voltage spark for ignition and a flame-sensing signal back to the control board, preventing the gas valve from staying open if the burner fails to light.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized LPG Combustion:\u003c\/strong\u003e Specifically calibrated for Liquid Propane (LPG) environments, the burner head’s venturi interface facilitates the correct air-to-fuel ratio for a clean, blue, soot-free flame.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurner Head:\u003c\/strong\u003e 30268, 36043.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnitor Electrode:\u003c\/strong\u003e 35100, 91788.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cp\u003eThis kit is the primary ignition and combustion set for Atwood and Dometic (Hydro Flame) RV furnaces. Key compatible series include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAtwood Hydro Flame 79 Series:\u003c\/strong\u003e Fits 7912, 7916, and 7920 models (including II and HF versions).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAtwood Hydro Flame 85 Series:\u003c\/strong\u003e Compatible with 8516, 8520, 8525, 8531, and 8535 (including III and IV iterations).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAFS \u0026amp; AFM Series:\u003c\/strong\u003e Direct fit for the newer Atwood Foundation Series (AFS) and Mid-Size (AFM) RV furnaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDometic Furnaces:\u003c\/strong\u003e Compatible with modern Dometic-branded units that utilize legacy Atwood internal components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e While this kit fits both 79 and 85 series, please verify the physical shape of your burner—some older 89 series units may use a larger rectangular burner.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFurnace Won't Ignite:\u003c\/strong\u003e You hear the \"click-click-click\" of the igniter, but the burner fails to light, often due to a cracked ceramic insulator on the electrode or a clogged burner head.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\"Limit Switch\" or \"Ignition Lockout\" Errors:\u003c\/strong\u003e The furnace tries to light three times and then shuts down; this is often caused by a dirty electrode that can no longer sense the flame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSooting or Yellow Flame:\u003c\/strong\u003e Indicates the burner head slots are rusted or clogged with spider webs\/debris, causing incomplete combustion and dangerous carbon monoxide buildup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRumbling or Booming Sound:\u003c\/strong\u003e Delayed ignition caused by a weak spark or a rusted burner flange can lead to a small \"explosion\" when the gas finally ignites.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisible Corrosion:\u003c\/strong\u003e The burner head shows heavy rust or flakes of metal, or the electrode probe is burnt down\/shortened from years of heat exposure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First (\u003cmeta charset=\"utf-8\"\u003eCRITICAL):\u003c\/strong\u003e Shut off the main LP gas supply and disconnect the 12V DC power to the furnace before disassembly. Gas leaks and electrical sparks are a high-risk combination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the Gap (PRO TIP):\u003c\/strong\u003e Before installing the new 35100 electrode, ensure the spark gap (the distance between the probes) is set to \u003cstrong\u003e1\/8 inch (3.2mm)\u003c\/strong\u003e. If the gap is too wide or too narrow, the furnace will not light.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean the Burner Tube:\u003c\/strong\u003e While the burner head is removed, use a flexible brush or compressed air to clear the burner tube of spider webs. Spiders are attracted to the smell of propane and are the #1 cause of RV furnace failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the Ceramic:\u003c\/strong\u003e Inspect the new electrode for any hairline cracks in the white ceramic during shipping. A cracked insulator will cause the spark to jump to the frame instead of the burner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe Leak Test:\u003c\/strong\u003e After reassembling the gas manifold, use a non-corrosive gas leak detection bubbles\/solution on all fittings. Never use a flame to check for propane leaks.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":46495303270589,"sku":"AZ00178514","price":41.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00166204_1.jpg?v=1773213042"},{"product_id":"33082-sail-switch-with-bracket-2pack","title":"33082 Sail Switch with Bracket - For Dometic Atwood RV Furnace Sail Switch - SVC Df Sail Sw W\/Brkt M\/L Kit - 2 Pack","description":"\u003ch2\u003e33082 Sail Switch with Bracket\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirflow Safety Sensing:\u003c\/strong\u003e Designed to detect sufficient blower motor speed by reacting to the \"wind\" (airflow) inside the furnace; if the sail does not move, the furnace will not ignite, preventing overheating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Microswitch:\u003c\/strong\u003e Features a high-sensitivity internal switch that closes the circuit only when the blower reaches the RPM threshold required for safe combustion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion-Resistant Bracket:\u003c\/strong\u003e Includes a pre-attached metal mounting bracket designed for a direct fit, ensuring the switch is positioned at the optimal angle within the air plenum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Temperature Housing:\u003c\/strong\u003e The switch body is constructed from heat-stabilized materials to maintain electrical integrity within the intense thermal environment of an RV furnace.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Large Sail:\u003c\/strong\u003e Features the \"Large Sail\" design (M\/L Kit) to ensure reliable engagement even in systems with slightly reduced airflow or older blower motors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e33082\u003c\/li\u003e\n\u003cli\u003e36165\u003c\/li\u003e\n\u003cli\u003e4471008700\u003c\/li\u003e\n\u003cli\u003e33063\u003c\/li\u003e\n\u003cli\u003e31094\u003c\/li\u003e\n\u003cli\u003e31094MC\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cp\u003eThis sail switch is a standard replacement for many Dometic and Atwood RV furnaces. Key compatible series include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAtwood\/Dometic DF Series:\u003c\/strong\u003e DFMD20, DFMD25, DFMD30, DFMD35 (Medium\/Large).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAtwood\/Dometic AF Series:\u003c\/strong\u003e AFMD20, AFMD25, AFMD30, AFMD35.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmall Furnace Compatibility:\u003c\/strong\u003e While primarily for Medium\/Large (M\/L) models, it replaces switches in many newer Dometic digital-controlled furnaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e Not compatible with older \"Hydro Flame\" 8500-IV series furnaces that use the smaller, square sail design.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Runs but No Heat:\u003c\/strong\u003e The furnace fan turns on, but you never hear the \"click\" of the gas valve or the \"tick-tick-tick\" of the igniter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntermittent Ignition:\u003c\/strong\u003e The furnace sometimes lights but often fails, which can be caused by a bent sail or a weak internal microswitch spring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Damage:\u003c\/strong\u003e The thin metal sail is bent, crimped, or missing, preventing it from catching enough air to move the switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLint\/Debris Build-up:\u003c\/strong\u003e Excessive dust or pet hair has clogged the switch pivot point, making the sail too \"heavy\" to move under normal blower pressure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccessing the Switch:\u003c\/strong\u003e Most modern DF series furnaces require removing the exterior access cover; the sail switch is typically located on the side of the blower housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrientation:\u003c\/strong\u003e Note the direction of the old sail before removal. The \"sail\" (the thin metal flap) must be facing \u003cstrong\u003einto\u003c\/strong\u003e the path of the blower air.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Connections:\u003c\/strong\u003e The two wires can generally be connected to either terminal on the switch, as it is a simple \"normally open\" circuit that closes when air pushes the sail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearance Check:\u003c\/strong\u003e Once mounted, gently push the sail with your finger to ensure it moves freely and clicks the microswitch without hitting the sides of the mounting slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest the Blower:\u003c\/strong\u003e If a new switch doesn't fix the issue, check your battery voltage or blower motor speed; if the motor is spinning too slowly, it won't produce enough air to move even a brand-new sail switch.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":46497317683389,"sku":"AZ00183032","price":17.87,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00247757_1.jpg?v=1764142459"},{"product_id":"pucb98-control-board-heat-sensor","title":"PU-CB98 PU-CBHS Control Board Heat Sensor - For Englander Pellet \u0026 Multi-Fuel Stoves 10-CDV 10-CPM 25-EP 25-EPI","description":"\u003ch2\u003ePU-CB98 \/ PU-CBHS Control Board Heat Sensor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Thermal Monitoring:\u003c\/strong\u003e Provides real-time heat data to the control board, allowing the stove to accurately determine when to activate the room air blower or trigger a safety shutdown.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug-and-Play Connector:\u003c\/strong\u003e Equipped with a standard white plastic molex-style connector for a direct, secure interface with the Englander control board, requiring no wire stripping or crimping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Temperature Insulation:\u003c\/strong\u003e Features high-grade insulated lead wires designed to withstand the intense radiant heat within the stove's internal cabinet without melting or shorting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Thermistor Probe:\u003c\/strong\u003e The sensor tip is encased in a corrosion-resistant metal housing to protect the sensitive electronics from the abrasive nature of pellet ash and soot.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003ePU-CBHS\u003c\/li\u003e\n\u003cli\u003ePU-CB98\u003c\/li\u003e\n\u003cli\u003ePU-CB04\u003c\/li\u003e\n\u003cli\u003ePH-EHS\u003c\/li\u003e\n\u003cli\u003ePU-CBHS-AMP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cp\u003eThis heat sensor is compatible with a wide array of pellet and multi-fuel stoves manufactured by England Stove Works (ESW). Key compatible models include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnglander Pellet Stoves:\u003c\/strong\u003e 25-PDV, 25-PDVC, 25-EP, 25-EPI, 25-IP, 25-PAF, 25-PFS, 25-PI, 25-PUF.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Fuel Models:\u003c\/strong\u003e 10-CDV, 10-CPM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand Cross-Compatibility:\u003c\/strong\u003e Also fits Summers Heat (SHP\/SHP series) and Timberland (TRP series) models that share the Englander chassis designs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\"E-1\" or \"E-2\" Error Codes:\u003c\/strong\u003e The digital display on the control board shows an error code indicating the sensor circuit is either open (disconnected) or shorted.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoom Blower Failure:\u003c\/strong\u003e The fire is burning hot, but the room air fan never turns on to distribute heat, suggesting the sensor isn't telling the board the stove is warm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStove Shuts Down Early:\u003c\/strong\u003e The stove enters the startup sequence but shuts down after 15–20 minutes because it fails to detect a rise in temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisible Heat Damage:\u003c\/strong\u003e The sensor wires are melted, charred, or have been pinched in the stove’s side panels or by the auger motor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Always unplug the stove and let it cool completely before opening the side or rear access panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Placement:\u003c\/strong\u003e The sensor is typically mounted on the exhaust blower housing or a nearby firewall. Note the exact orientation of the old probe before removing the mounting screw to ensure accurate readings from the new unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Routing:\u003c\/strong\u003e Avoid routing the wires near the exhaust pipe or moving parts like the auger shaft. Use high-heat zip ties to keep the wiring harness clear of hot surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure Connection:\u003c\/strong\u003e Ensure the molex connector is pushed all the way into the control board until it clicks; a loose plug is a common cause of intermittent \"E-1\" errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean the Area:\u003c\/strong\u003e While the stove is open, use a vacuum to remove ash buildup around the sensor mounting point, as excessive ash can insulate the probe and cause sluggish performance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":46497319518397,"sku":"AZ00221328","price":25.01,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00221328_1.jpg?v=1765940097"},{"product_id":"idxlfls1930-flame-sensor-replacement","title":"IDXLFLS1930 Flame Sensor for Hayward H-Series Induced Draft \u0026 Gas Pool Heater - Fits H150FD H200FD H250FD","description":"\u003ch2\u003eIDXLFLS1930 Flame Sensor Replacement\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect replacement for original equipment flame sensor.\u003c\/li\u003e\n\u003cli\u003eDetects the presence of flame in the combustion chamber.\u003c\/li\u003e\n\u003cli\u003eSignals the ignition control module to maintain gas flow.\u003c\/li\u003e\n\u003cli\u003eEssential safety component for proper heater operation.\u003c\/li\u003e\n\u003cli\u003eConstructed from materials designed for high-temperature environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eIDXLFLS1930\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBrand: Hayward\u003c\/li\u003e\n\u003cli\u003eSeries: Universal H-Series Low NOx Induced Draft Heaters\u003c\/li\u003e\n\u003cli\u003eFits both Natural Gas (FDN) and Propane (FDP) models.\u003c\/li\u003e\n\u003cli\u003eCompatible Models Include: H150FD, H200FD, H250FD, H300FD, H350FD, H400FD, H500FD\u003c\/li\u003e\n\u003cli\u003eAlso fits IDL and IDL2 models such as H250IDL2 and H350IDL2.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHeater ignites briefly then shuts off after a few seconds.\u003c\/li\u003e\n\u003cli\u003eHeater fails to detect a flame and locks out.\u003c\/li\u003e\n\u003cli\u003eControl panel displays an error code related to ignition or flame sense failure.\u003c\/li\u003e\n\u003cli\u003eVisible corrosion, heavy carbon buildup, or cracking on the sensor's metal rod or ceramic insulator.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all electrical power and turn off the gas supply to the heater before service.\u003c\/li\u003e\n\u003cli\u003eThe flame sensor is located inside the burner chamber, positioned in the direct path of the flame.\u003c\/li\u003e\n\u003cli\u003eDisconnect the single wire and remove the mounting screw to release the old sensor.\u003c\/li\u003e\n\u003cli\u003eInstall the new sensor and ensure the rod is correctly positioned without touching other metal components.\u003c\/li\u003e\n\u003cli\u003eSecurely fasten the mounting screw and reconnect the wire.\u003c\/li\u003e\n\u003cli\u003eAfter installation, restore power and gas, then verify the heater cycles correctly.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":46609421664445,"sku":"AZ00143907","price":31.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00143907_1.jpg?v=1775538269"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/collections\/Furnace.png?v=1754448579","url":"https:\/\/bluestarspartstrend.com\/collections\/house-furnace-parts.oembed?page=2","provider":"BlueStars Parts","version":"1.0","type":"link"}