{"title":"Ruud Brand","description":null,"products":[{"product_id":"2pack-622354301-furnace-flame-sensor","title":"62-23543-01 Furnace Flame Sensor Replacement - For Rheem, Ruud, WeatherKing, Thermal Zone, DuroGuard Furnace - 2 Pack","description":"\u003ch2\u003e62-23543-01 Furnace Flame Sensor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSensing Rod Material: Metal alloy\u003c\/li\u003e\n\u003cli\u003eInsulator Material: Alumina ceramic\u003c\/li\u003e\n\u003cli\u003eTermination: 1\/4 inch male quick connect\u003c\/li\u003e\n\u003cli\u003eTotal Length (Mounting Flange to Sensor Tip): 2-1\/2 inches\u003c\/li\u003e\n\u003cli\u003eSensor Offset Length: 1-9\/16 inches\u003c\/li\u003e\n\u003cli\u003eSensor Offset Angle: 90 degrees\u003c\/li\u003e\n\u003cli\u003eFunction: Detects burner flame for safe furnace operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e62-23543-01\u003c\/li\u003e\n\u003cli\u003e62-23543-02\u003c\/li\u003e\n\u003cli\u003e62-23543-03\u003c\/li\u003e\n\u003cli\u003e62-23543-04\u003c\/li\u003e\n\u003cli\u003ePSE-RH8\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for Hot Surface Ignition (HSI) and spark ignition systems\u003c\/li\u003e\n\u003cli\u003eCompatible with gas furnaces from brands including Rheem, Ruud, WeatherKing, Thermal Zone, and DuroGuard\u003c\/li\u003e\n\u003cli\u003eMounts directly on the burner assembly or adjacent to the igniter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace ignites but shuts down after a few seconds\u003c\/li\u003e\n\u003cli\u003eFurnace control board indicates a flame sensor fault or error code\u003c\/li\u003e\n\u003cli\u003eVisible carbon buildup, corrosion, or damage to the existing sensor rod\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect electrical power and shut off the gas supply to the furnace before servicing.\u003c\/li\u003e\n\u003cli\u003eAvoid touching the metal sensor rod with bare hands; skin oils can cause premature failure. Handle with clean gloves or a cloth.\u003c\/li\u003e\n\u003cli\u003eHandle the ceramic insulator carefully to prevent cracks or damage.\u003c\/li\u003e\n\u003cli\u003eEnsure the sensor rod is properly positioned in the path of the flame for accurate detection.\u003c\/li\u003e\n\u003cli\u003eConfirm all electrical connections are secure before restoring power.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45367044964541,"sku":"AZ00675604","price":11.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00675604_1_5f890f62-ab42-42f1-9702-273aadee8cfa.jpg?v=1762246878"},{"product_id":"69w43-furnace-flame-sensor","title":"69W43 Furnace Flame Sensor - Exact ForLennox, Armstrong \u0026 Ducane Furnaces","description":"\u003ch2\u003e69W43 Furnace Flame Sensor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSensing rod detects flame presence for furnace operation\u003c\/li\u003e\n\u003cli\u003eAngled probe design\u003c\/li\u003e\n\u003cli\u003eOverall width: 4-5\/8 in\u003c\/li\u003e\n\u003cli\u003eFeatures a 3\/16 in male terminal for connection\u003c\/li\u003e\n\u003cli\u003eDurable construction for long service life\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e69W43\u003c\/li\u003e\n\u003cli\u003e69W4301\u003c\/li\u003e\n\u003cli\u003eLB-74940B\u003c\/li\u003e\n\u003cli\u003eLB74940B\u003c\/li\u003e\n\u003cli\u003e102431-02\u003c\/li\u003e\n\u003cli\u003e790-801A1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect replacement for specific furnace models from brands including:\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eArmstrong\u003c\/li\u003e\n\u003cli\u003eDucane\u003c\/li\u003e\n\u003cli\u003eLennox\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eVerify compatibility with your furnace model number prior to purchase.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace starts the ignition sequence but shuts off after a few seconds.\u003c\/li\u003e\n\u003cli\u003eFurnace control board indicates a flame sensor fault code.\u003c\/li\u003e\n\u003cli\u003eVisible carbon buildup, corrosion, or damage on the existing sensor rod.\u003c\/li\u003e\n\u003cli\u003eThe ceramic insulator is cracked or broken.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect electrical power to the furnace unit before servicing.\u003c\/li\u003e\n\u003cli\u003eAvoid touching the metal rod with bare hands; handle by the ceramic base.\u003c\/li\u003e\n\u003cli\u003eEnsure the sensor is correctly positioned in the pilot or main burner flame.\u003c\/li\u003e\n\u003cli\u003eConfirm the mounting screw and wire are securely fastened.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45367045095613,"sku":"AZ1382207","price":11.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00143111_1_b521424f-6bd1-487b-90c1-22ac01d88c48.jpg?v=1762246877"},{"product_id":"1183200-ignitor-hot-surface","title":"1183200 Round Hot Surface Igniter - Replaces 1177545 41-224 - For Southbend Range","description":"\u003ch2\u003e1183200 Round Hot Surface Igniter\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-temperature silicon carbide heating element designed for rapid, reliable ignition in commercial oven environments.\u003c\/li\u003e\n\u003cli\u003eRobust ceramic base provides electrical insulation and heat resistance during continuous operation.\u003c\/li\u003e\n\u003cli\u003eEquipped with high-temperature fiberglass-insulated lead wires for protection against thermal degradation.\u003c\/li\u003e\n\u003cli\u003ePrecision-engineered round design ensures uniform heat distribution and consistent ignition timing.\u003c\/li\u003e\n\u003cli\u003eDirect-fit replacement designed to meet or exceed commercial-grade performance standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1183200\u003c\/li\u003e\n\u003cli\u003e1177545\u003c\/li\u003e\n\u003cli\u003e41-224\u003c\/li\u003e\n\u003cli\u003e1177545-SB\u003c\/li\u003e\n\u003cli\u003eF1183200\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with Southbend commercial gas ranges, convection ovens, and broiler units.\u003c\/li\u003e\n\u003cli\u003eFits Southbend model series: BGS\/12SC, BGS\/22SC, CG\/12SC, and CG\/22SC.\u003c\/li\u003e\n\u003cli\u003eDesigned for use in high-demand commercial kitchens and professional foodservice equipment.\u003c\/li\u003e\n\u003cli\u003eSuitable for various Southbend Silverstar and Platinum series convection ovens utilizing hot surface ignition systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOven fails to ignite or maintain a flame during the heating cycle.\u003c\/li\u003e\n\u003cli\u003eThe igniter element shows visible cracks, breaks, or localized white oxidation spots.\u003c\/li\u003e\n\u003cli\u003eThe igniter fails to glow when the oven is powered on and calling for heat.\u003c\/li\u003e\n\u003cli\u003eIgniter amperage draw is below the threshold required to open the gas safety valve.\u003c\/li\u003e\n\u003cli\u003eError codes related to ignition failure or flame sensing are displayed on the control board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect the electrical power supply and shut off the main gas line before beginning the repair.\u003c\/li\u003e\n\u003cli\u003eAllow the oven to cool completely to avoid burns from surrounding metal components.\u003c\/li\u003e\n\u003cli\u003eHandle the new igniter only by the ceramic base; do not touch the black heating element, as skin oils can lead to hotspots and premature failure.\u003c\/li\u003e\n\u003cli\u003eCarefully remove the mounting screws and old igniter, noting the original wiring path.\u003c\/li\u003e\n\u003cli\u003eSecure the new igniter in the same orientation as the original to ensure the element is correctly positioned in the gas flow path.\u003c\/li\u003e\n\u003cli\u003eUse high-temperature porcelain wire nuts if the original electrical connectors require modification.\u003c\/li\u003e\n\u003cli\u003eRestore power and gas, then run a test cycle to confirm the element glows and the gas ignites promptly.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45367297245373,"sku":"AZ00260433","price":47.29,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00260433_1_773e8dcc-b68c-4c73-9476-6e774a143999.jpg?v=1762246806"},{"product_id":"10002264-propane-and-natural-gas-pilot","title":"10002264 Natural Gas 3-Way Pilot Assembly Kit for HHT Majestic Monessen Temco Vermont Castings Fireplaces - SRV10002264 LP NG 3-Way Pilot with Thermocouple","description":"\u003ch2\u003e10002264 \/ SRV10002264 Natural Gas 3-Way Pilot Assembly Kit\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive 3-Way Pilot System:\u003c\/strong\u003e A complete ignition solution featuring the pilot burner hood, a high-output thermopile, a precision thermocouple, and a ceramic electrode, ensuring reliable ignition and flame sensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Sensor Safety Technology:\u003c\/strong\u003e Utilizes both a thermocouple (to verify the pilot flame) and a thermopile (to generate the millivolts required to open the main gas valve), providing redundant safety and electrical independent operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Temperature Stainless Steel Hood:\u003c\/strong\u003e The 3-way pilot hood is manufactured from corrosion-resistant stainless steel, designed to direct the flame precisely toward the sensors and the main burner for a smooth \"cross-over\" ignition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision NG Orifice:\u003c\/strong\u003e Pre-installed with a Natural Gas (NG) orifice calibrated for optimal fuel-to-air mixing, resulting in a stable, blue pilot flame that resists drafting and lifting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Lead Wires:\u003c\/strong\u003e Features 24-inch heat-shielded lead wires for both the thermocouple and thermopile, allowing for flexible routing away from the high-heat zones of the firebox.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSRV10002264\u003c\/li\u003e\n\u003cli\u003e230-1781\u003c\/li\u003e\n\u003cli\u003e10002265\u003c\/li\u003e\n\u003cli\u003e2103-010\u003c\/li\u003e\n\u003cli\u003e2103-011\u003c\/li\u003e\n\u003cli\u003e4021-736\u003c\/li\u003e\n\u003cli\u003e485-510A\u003c\/li\u003e\n\u003cli\u003e10001741\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cp\u003eThis 3-way pilot assembly is the primary ignition component for millivolt (standing pilot) fireplaces manufactured by Hearth \u0026amp; Home Technologies (HHT). Key compatible brands include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMajestic:\u003c\/strong\u003e Fits various models in the \u003cstrong\u003eDVR\u003c\/strong\u003e, \u003cstrong\u003eDVRT\u003c\/strong\u003e, \u003cstrong\u003eDVS\u003c\/strong\u003e, and \u003cstrong\u003eDVT\u003c\/strong\u003e series (e.g., DVR33, DVT36, DVRT42).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVermont Castings:\u003c\/strong\u003e Compatible with many \u003cstrong\u003eDirect Vent\u003c\/strong\u003e and \u003cstrong\u003eB-Vent\u003c\/strong\u003e units including the Radiance and Stardance series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonessen:\u003c\/strong\u003e Fits standard millivolt series such as the \u003cstrong\u003eBDV\u003c\/strong\u003e, \u003cstrong\u003eCDV\u003c\/strong\u003e, and \u003cstrong\u003eMDV\u003c\/strong\u003e units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemco:\u003c\/strong\u003e Direct replacement for several ADVP and DV series fireplaces utilizing the SIT-style pilot bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e This kit is configured for \u003cstrong\u003eNatural Gas\u003c\/strong\u003e. To use with Propane (LP), you must swap the internal pilot orifice (typically a #35 or #51 depending on the model).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePilot Will Not Stay Lit:\u003c\/strong\u003e After releasing the knob, the pilot flame goes out instantly. This indicates a failed \u003cstrong\u003eThermocouple\u003c\/strong\u003e that can no longer hold the safety magnet open.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain Burner Won't Ignite:\u003c\/strong\u003e The pilot is lit, but the main logs never turn on. This suggests the \u003cstrong\u003eThermopile\u003c\/strong\u003e is not generating the required 325–750 millivolts to trigger the gas valve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSooting or Yellow Flame:\u003c\/strong\u003e The pilot hood or orifice is clogged with carbon or spider webs, causing an \"unclean\" flame that prevents the sensors from heating properly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Spark During Lighting:\u003c\/strong\u003e The ceramic insulator on the electrode is cracked or the wire is frayed, preventing the piezo igniter from creating a spark to light the pilot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelayed Ignition:\u003c\/strong\u003e The pilot flame is weak or misdirected, causing gas to build up before the main burner finally \"poofs\" or bangs during ignition.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First:\u003c\/strong\u003e You MUST \u003cstrong\u003eshut off the gas supply\u003c\/strong\u003e and ensure the fireplace has completely cooled. Gas fireplace interiors can retain dangerous levels of heat long after use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe \"Millivolt\" Test:\u003c\/strong\u003e Before replacing the whole assembly, use a multimeter to check the thermopile. If it reads above 325mV while the pilot is hitting it, your problem might be the gas valve or the wall switch, not the pilot kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvoid Kinking:\u003c\/strong\u003e The thermocouple and pilot tube are made of soft copper\/aluminum. Be extremely careful not to \"kink\" the lines during routing, as this can restrict gas flow or break the internal sensor wire.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinger-Tight Plus:\u003c\/strong\u003e Thread the thermocouple nut into the back of the gas valve by hand until snug, then give it only a **1\/4 turn** with a wrench. Overtightening can crush the sensitive internal copper connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean the Orifice:\u003c\/strong\u003e If you are re-using your old pilot tube, ensure the orifice is clear of debris. Never use a drill bit to clean an orifice; use compressed air or a fine needle to avoid enlarging the hole.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45367303143613,"sku":"AZ00911971","price":42.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00911971_1_d47442ce-fb85-437a-bd2d-dc6ad9fda288.jpg?v=1762246794"},{"product_id":"405-mfd-uf-370-or-440-volt-vac-round-dual-run-capacitor","title":"40+5 uF MFD 370\/440 VAC Round Dual Run Capacitor Dual Run Circular Start Capacitor - For Air Conditioner, Heat Pump","description":"\u003ch2\u003e40+5 MFD uF 370 or 440 Volt VAC Round Dual Run Capacitor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCapacitance: 40 + 5 Microfarad (MFD)\u003c\/li\u003e\n\u003cli\u003eVoltage Rating: 370V or 440V AC\u003c\/li\u003e\n\u003cli\u003eTolerance: +\/- 5%\u003c\/li\u003e\n\u003cli\u003eFrequency: 50 \/ 60 Hz\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -40°C to +70°C (-40°F to +158°F)\u003c\/li\u003e\n\u003cli\u003eConstruction: Round aluminum case\u003c\/li\u003e\n\u003cli\u003eTerminals: 3-terminal configuration (C, HERM, FAN)\u003c\/li\u003e\n\u003cli\u003eSafety Standard: 10,000 AFC fault current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUSA2235\u003c\/li\u003e\n\u003cli\u003eTRCFD405\u003c\/li\u003e\n\u003cli\u003eP291-4054RS\u003c\/li\u003e\n\u003cli\u003eC3405R\u003c\/li\u003e\n\u003cli\u003eC4405R\u003c\/li\u003e\n\u003cli\u003e27L880\u003c\/li\u003e\n\u003cli\u003ePRCFD405\u003c\/li\u003e\n\u003cli\u003eHC98JA041\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUniversal replacement for round dual run capacitors with matching 40\/5 MFD capacitance and 370V or 440V ratings.\u003c\/li\u003e\n\u003cli\u003eA 440V capacitor can replace a 370V capacitor; do not replace a 440V capacitor with a 370V unit.\u003c\/li\u003e\n\u003cli\u003eUsed in air conditioner condensers, heat pumps, and other HVAC systems.\u003c\/li\u003e\n\u003cli\u003ePhysical dimensions are approximately 2.0 - 2.4 inches in diameter and 3.7 - 5.25 inches in height. Verify fitment before purchase.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit fan does not spin.\u003c\/li\u003e\n\u003cli\u003eCompressor hums but will not start.\u003c\/li\u003e\n\u003cli\u003eHVAC system is running but not cooling.\u003c\/li\u003e\n\u003cli\u003eVisible signs of failure, such as a bulging or leaking capacitor case.\u003c\/li\u003e\n\u003cli\u003eCapacitance measures outside the specified tolerance when tested with a multimeter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all electrical power to the HVAC unit before servicing.\u003c\/li\u003e\n\u003cli\u003eDischarge the existing capacitor by shorting across the terminals with an insulated-handle screwdriver.\u003c\/li\u003e\n\u003cli\u003ePhotograph or note the wire placement on the C, HERM, and FAN terminals before disconnecting.\u003c\/li\u003e\n\u003cli\u003eConnect the wires to the corresponding terminals on the new capacitor.\u003c\/li\u003e\n\u003cli\u003eSecure the new capacitor with the original mounting bracket to prevent vibration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45367447486653,"sku":"AZ00224529","price":25.12,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00224529_1_21f6b555-3d79-4bac-9e5c-5acf5d5a630b.jpg?v=1762246716"},{"product_id":"32x32x36-central-air-conditioner-covers","title":"32\"x32\"x36\" Central Air Conditioner Cover for Outside Units - Waterproof \u0026 Windproof Outdoor AC Units Cover (Black)","description":"\u003ch2\u003e32\"x32\"x36\" Central Air Conditioner Covers\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions: 32\" L x 32\" W x 36\" H\u003c\/li\u003e\n\u003cli\u003eMaterial: Heavy-duty, weather-resistant polyester fabric\u003c\/li\u003e\n\u003cli\u003eProtects outdoor A\/C unit from rain, snow, sun, dirt, leaves, and debris\u003c\/li\u003e\n\u003cli\u003eWaterproof and UV-resistant construction\u003c\/li\u003e\n\u003cli\u003eStructured air vents reduce wind lofting and inside condensation\u003c\/li\u003e\n\u003cli\u003eElastic hem cord and adjustable buckle straps for a secure fit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUniversal fit cover; not a direct replacement for specific OEM part numbers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFits most standard square central air conditioner units up to 32\" L x 32\" W x 36\" H.\u003c\/li\u003e\n\u003cli\u003eCompatible with many major brands including Carrier, Goodman, Lennox, Rheem, and Trane.\u003c\/li\u003e\n\u003cli\u003eNote: Always measure your A\/C unit's dimensions before purchasing to ensure proper fit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVisible signs of damage such as tears, rips, or holes.\u003c\/li\u003e\n\u003cli\u003eFabric has become brittle or cracked from sun exposure.\u003c\/li\u003e\n\u003cli\u003eWater-resistant coating is no longer effective.\u003c\/li\u003e\n\u003cli\u003eStraps or buckles are broken or missing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eImportant: Ensure the air conditioner unit is powered off at the breaker before covering.\u003c\/li\u003e\n\u003cli\u003eClear any leaves, twigs, or debris from the top and sides of the unit.\u003c\/li\u003e\n\u003cli\u003ePlace the cover over the A\/C unit.\u003c\/li\u003e\n\u003cli\u003eAdjust the elastic hem cord and secure the buckle straps for a tight fit around the bottom.\u003c\/li\u003e\n\u003cli\u003eEnsure air vents on the cover remain unobstructed to allow for airflow.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45367449518269,"sku":"AZ00240376","price":11.39,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00240376_1_6ec96b05-8ccd-488d-8d5f-1a43257e169d.jpg?v=1762246663"},{"product_id":"30x30x32-central-air-conditioner-covers","title":"30\"x30\"x32\" Central Air Conditioner Cover for Outside Units - Waterproof \u0026 Windproof Outdoor AC Units Cover (Black)","description":"\u003ch2\u003e30\"x30\"x32\" Central Air Conditioner Covers\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eConstructed from heavy-duty 210D polyester Oxford fabric.\u003c\/li\u003e\n\t\u003cli\u003eFeatures a water-resistant PVC inner coating for enhanced weather protection.\u003c\/li\u003e\n\t\u003cli\u003eProtects outdoor units from rain, snow, sun exposure, dirt, and debris.\u003c\/li\u003e\n\t\u003cli\u003eVented design promotes air circulation to prevent moisture and condensation buildup.\u003c\/li\u003e\n\t\u003cli\u003eIncludes an adjustable bottom draw-cord for a secure, customized fit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eUniversal fit for outdoor AC units matching the specified dimensions. Not a direct replacement for OEM-branded covers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for standard square central air conditioner units.\u003c\/li\u003e\n\t\u003cli\u003eMaximum Fit Dimensions: 30\" Length x 30\" Width x 32\" Height.\u003c\/li\u003e\n\t\u003cli\u003eVerify your AC unit's external dimensions prior to purchase to ensure a proper fit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eIf the cover has visible tears, punctures, or seam separation.\u003c\/li\u003e\n\t\u003cli\u003eWhen the material shows signs of significant fading or degradation from UV exposure.\u003c\/li\u003e\n\t\u003cli\u003eIf the water-resistant coating is no longer effective at repelling moisture.\u003c\/li\u003e\n\t\u003cli\u003eWhen the adjustable cord or securing mechanism is broken or fails to tighten.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eEnsure the air conditioner is powered off before covering for extended periods (e.g., winter).\u003c\/li\u003e\n\t\u003cli\u003eClean any leaves, twigs, or debris from the top and sides of the AC unit before installation.\u003c\/li\u003e\n\t\u003cli\u003ePosition the cover over the unit, aligning the corners.\u003c\/li\u003e\n\t\u003cli\u003ePull the adjustable draw-cord at the base until the cover is snug and secure against wind.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45367449551037,"sku":"AZ00216102","price":14.29,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00216102_1_6f75d2ff-272f-4046-a4e8-fef02485a159.jpg?v=1762246662"},{"product_id":"24x24x30-central-air-conditioner-covers","title":"24\"x24\"x30\" Central Air Conditioner Covers for Outside Unit - Waterproof \u0026 Windproof Outdoor AC Units Cover (Black)","description":"\u003ch2\u003e24\"x24\"x30\" Central Air Conditioner Covers\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions: 24\" L x 24\" W x 30\" H\u003c\/li\u003e\n\u003cli\u003eMaterial: Heavy-duty, water-resistant polyester fabric (420D to 600D)\u003c\/li\u003e\n\u003cli\u003eProtects outdoor condenser units from rain, snow, sun, leaves, and debris\u003c\/li\u003e\n\u003cli\u003eStructured air vents reduce interior condensation and wind lofting\u003c\/li\u003e\n\u003cli\u003eAdjustable bottom hem cord or straps provide a secure, custom fit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUniversal fit for covers designed for 24x24x30 inch units\u003c\/li\u003e\n\u003cli\u003eAlternative to OEM covers for brands such as Luxaire, Guardian, Lennox, and others requiring similar dimensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFits most standard square central air conditioner outdoor units up to 24\"L x 24\"W x 30\"H\u003c\/li\u003e\n\u003cli\u003eCompatible with many models from brands including Trane, Carrier, Goodman, Lennox, Rheem, York, and Ruud\u003c\/li\u003e\n\u003cli\u003eMeasure your AC unit to confirm fitment before ordering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExisting cover is torn, cracked, or has holes\u003c\/li\u003e\n\u003cli\u003eMaterial has become brittle or degraded due to UV exposure\u003c\/li\u003e\n\u003cli\u003eFastening mechanisms like straps or drawstrings are broken or missing\u003c\/li\u003e\n\u003cli\u003eCurrent cover no longer provides adequate protection from water and debris\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurn off power to the air conditioner at the circuit breaker before covering\u003c\/li\u003e\n\u003cli\u003eRemove any leaves, twigs, or other debris from the top and sides of the unit\u003c\/li\u003e\n\u003cli\u003ePlace the cover over the unit, aligning the corners\u003c\/li\u003e\n\u003cli\u003eTighten the bottom drawstring or fastening straps for a secure fit\u003c\/li\u003e\n\u003cli\u003eEnsure side vents on the cover remain clear to allow for air circulation\u003c\/li\u003e\n\u003cli\u003eImportant: Remove cover completely before operating the air conditioner\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45367450763453,"sku":"AZ00317865","price":10.19,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00317865_1_cec2820c-5432-4525-8229-d6576141646e.jpg?v=1762246644"},{"product_id":"2prong-93868-water-heater-igniter-and-sense-electrode","title":"2-Prong 93868 Water Heater Igniter and Sense Electrode","description":"\u003ch2\u003e2-Prong 93868 Water Heater Igniter and Sense Electrode\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual-function design integrates the igniter and flame sensor into a single component.\u003c\/li\u003e\n\u003cli\u003eFeatures a 2-prong connection for specified water heater models.\u003c\/li\u003e\n\u003cli\u003eConstructed with a high-temperature resistant ceramic insulator for durability.\u003c\/li\u003e\n\u003cli\u003eEngineered as a direct-fit replacement to ensure proper function.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAtwood \/ Dometic:\u003c\/strong\u003e 93868\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cp\u003eDesigned for specific Atwood and Dometic brand RV propane water heaters. Common compatible models include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGC6AA-10E\u003c\/li\u003e\n\u003cli\u003eGCH6-4E\u003c\/li\u003e\n\u003cli\u003eGCH6-6E\u003c\/li\u003e\n\u003cli\u003eGCH6A-10E\u003c\/li\u003e\n\u003cli\u003eGC6A-7E\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cp\u003eConsider replacement if your water heater exhibits the following symptoms:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFailure to ignite or intermittent ignition.\u003c\/li\u003e\n\u003cli\u003eBurner lights but shuts down after a few seconds.\u003c\/li\u003e\n\u003cli\u003eVisible damage, such as a cracked ceramic insulator or corroded metal probes.\u003c\/li\u003e\n\u003cli\u003eFault codes indicating an ignition or flame sense error.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all power and shut off the propane supply before installation.\u003c\/li\u003e\n\u003cli\u003eEnsure the new electrode is positioned correctly with the proper gap according to the water heater manufacturer's specifications.\u003c\/li\u003e\n\u003cli\u003eConfirm all wire connections are clean and secure.\u003c\/li\u003e\n\u003cli\u003eAfter installation, perform a leak check and test for proper ignition sequence and operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45367455088829,"sku":"AZ00109075","price":17.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00109075_1_a2838151-c506-4478-b9d3-d732a6033feb.jpg?v=1762246617"},{"product_id":"100112330-water-heater-pilot-assembly","title":"100112330 Water Heater Pilot and Igniter Assembly for Natual Gas","description":"\u003ch2\u003e100112330 Water Heater Pilot \u0026amp; Igniter Assembly for Natural Gas Water Heaters\u003c\/h2\u003e\n\u003cp\u003e\nThe 100112330 Water Heater Pilot and Igniter Assembly is designed to provide reliable, consistent ignition for natural gas water heaters. Engineered to meet OEM specifications, this assembly restores safe and efficient burner operation, reducing ignition failures and ensuring dependable hot water performance.\n\u003c\/p\u003e\n\n\u003ch3\u003eReliable \u0026amp; Efficient Ignition\u003c\/h3\u003e\n\u003cp\u003e\nThis pilot assembly features a precision pilot tube, responsive thermocouple, and durable igniter to ensure fast and stable ignition. It helps eliminate common problems such as pilot outages, delayed ignition, and inconsistent burner operation, keeping your water heater ready whenever hot water is needed.\n\u003c\/p\u003e\n\n\u003ch3\u003eDurable, Heat-Resistant Construction\u003c\/h3\u003e\n\u003cp\u003e\nBuilt with premium brass pilot tubing, a high-grade alloy thermocouple, and a heat-resistant ceramic igniter, this assembly is designed to withstand high temperatures, corrosion, and long-term use. Its rugged construction ensures reliable performance even in demanding operating conditions.\n\u003c\/p\u003e\n\n\u003ch3\u003eWide Compatibility\u003c\/h3\u003e\n\u003cp\u003e\nDesigned for use with many popular natural gas water heater brands, including:\n\u003cstrong\u003eReliance, Whirlpool, A.O. Smith, Kenmore, State, and American.\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003e\nReplaces part numbers:\n\u003cstrong\u003e100112330, 9007876, 9007877\u003c\/strong\u003e.\nThe assembly includes all essential components for a secure, leak-free installation.\n\u003c\/p\u003e\n\n\u003ch3\u003eCompatible Whirlpool Water Heater Models\u003c\/h3\u003e\n\u003cp\u003e\nN30T61-303, N40T61-403, N40T62-403, N50T61-403, N50T62-403, N50T91-403,  \nN40T61-353, N40S61-403, N40T121-403, 40S6-40NG,  \n40T6-34NG-400, 40T10-40NG-400, 50T6-40NG-400\n\u003c\/p\u003e\n\n\u003ch3\u003eCompatible American Water Heater Models\u003c\/h3\u003e\n\u003cp\u003e\nN30S61-303, N30T61-303, N40S61-403, N40T61-343, N40T62-403,  \nN40S91-403, N40T91-403, N40T121-403,  \nN50T61-403, N50T61-504, N50T91-403, N50T122-403, BFG6140T403NO\n\u003c\/p\u003e\n\n\u003ch3\u003eCompatible Kenmore Water Heater Models\u003c\/h3\u003e\n\u003cp\u003e\n153330290, 153331150, 153331492, 153331620, 153331630, 153331640,  \n153331651, 153331661, 153331670, 153331682, 153331830,  \n153330270, 153330250, 153331840, 153331851, 153331861,  \n153331592, 153331882, 153332421, 153336930, 153336931,  \n153336940, 153336941, 153556300, 153556400, 153556500,  \n153559400, 153559500, 153330230, 153330280, 153572400,  \n153572500, 153573400, 153576300, 153576310, 153576320,  \n153576400, 153576410, 153576420, 153576500, 153576510,  \n153579400, 153579410, 153579420, 153579500, 153579510\n\u003c\/p\u003e\n\n\u003ch3\u003eCompatible A.O. Smith Series\u003c\/h3\u003e\n\u003cp\u003e\nGS6-300, GCV-300, GPX-300, GVK-300, XCZ-300\n\u003c\/p\u003e\n\n\u003ch3\u003eCompatible Reliance Models\u003c\/h3\u003e\n\u003cp\u003e\n630 LORT\/LORS 301, 630 LOCT\/LOCS 401,  \n640 LORT\/LORS 301, 640 LOCT\/LBCS 401,  \n650 LORT 301\n\u003c\/p\u003e\n\n\u003ch3\u003eEasy Installation\u003c\/h3\u003e\n\u003cp\u003e\nThis pilot and igniter assembly is designed for straightforward replacement. Always turn off the gas supply and disconnect power before installation. Proper installation helps ensure safe operation and optimal ignition performance.\n\u003c\/p\u003e\n\n\u003ch3\u003eBuilt for Long-Term Reliability\u003c\/h3\u003e\n\u003cp\u003e\nManufactured to meet or exceed OEM standards, this water heater pilot assembly delivers dependable ignition, stable flame control, and long-lasting performance—making it an ideal replacement solution for restoring your natural gas water heater.\n\u003c\/p\u003e\n","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45367455187133,"sku":"AZ00268779","price":35.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00268779_1.jpg?v=1757320269"},{"product_id":"r0456500-temperature-sensor","title":"R0456500 Temperature Sensor","description":"\u003ch2\u003eR0456500 Temperature Sensor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect replacement temperature sensor for pool and spa heaters\u003c\/li\u003e\n\u003cli\u003eProvides accurate water temperature measurement to the heater control system\u003c\/li\u003e\n\u003cli\u003eKit often includes the sensor, mounting sleeve, and o-ring gasket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: Jandy \/ Zodiac \/ Teledyne Laars\u003c\/li\u003e\n\u003cli\u003ePart Number: R0456500\u003c\/li\u003e\n\u003cli\u003eUPC: 052337023283\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFits Jandy Legacy LRZE and LRZM heater models: 125, 175, 250, 325, 400\u003c\/li\u003e\n\u003cli\u003eFits Jandy LXi Low NOx heater models\u003c\/li\u003e\n\u003cli\u003eFits Jandy JXi heater models: 200, 260, 400\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHeater displays error codes related to the temperature sensor\u003c\/li\u003e\n\u003cli\u003eInaccurate or fluctuating water temperature readings on the heater display\u003c\/li\u003e\n\u003cli\u003eThe heater fails to fire or maintain a set temperature due to sensor failure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAlways disconnect all electrical power to the heater before performing service\u003c\/li\u003e\n\u003cli\u003eThe sensor is typically located on the left side of the heater's manifold assembly\u003c\/li\u003e\n\u003cli\u003eEnsure the o-ring gasket is properly seated to prevent leaks\u003c\/li\u003e\n\u003cli\u003eRefer to the heater's service manual for specific installation diagrams and procedures\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45367455350973,"sku":"AZ00188340","price":19.19,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00188340_1_4a50a9cc-ce82-4171-8612-ba891a7bd3c7.jpg?v=1762246613"},{"product_id":"csru2-hard-start-capacitor-kit","title":"CSR-U2 Hard Start Capacitor Kit - Fits Air Conditioner 3 1\/2 to 5 Ton Units","description":"\u003ch2\u003eCSR-U2 Hard Start Capacitor Kit\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCombines a high-power starting capacitor with an electronic potential relay.\u003c\/li\u003e\n\u003cli\u003eIncreases compressor starting torque for faster, more reliable start-ups.\u003c\/li\u003e\n\u003cli\u003eReduces start-up time, minimizing electrical stress on compressor windings and run capacitor.\u003c\/li\u003e\n\u003cli\u003eLowers inrush current, preventing light dimming and nuisance circuit breaker trips.\u003c\/li\u003e\n\u003cli\u003eDesigned as a three-wire kit for straightforward installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCSR-U2\u003c\/li\u003e\n\u003cli\u003eReplaces various OEM and aftermarket hard start kits with similar voltage and tonnage specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor use with single-phase 208V, 230V, and 265V air conditioning and heat pump systems.\u003c\/li\u003e\n\u003cli\u003eDesigned for compressors rated from 3.5 to 5 tons.\u003c\/li\u003e\n\u003cli\u003eCompatible with residential and light commercial PSC (Permanent Split Capacitor) compressor motors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall when the compressor struggles to start, especially during high ambient temperatures.\u003c\/li\u003e\n\u003cli\u003eRecommended if lights dim noticeably when the A\/C or heat pump activates.\u003c\/li\u003e\n\u003cli\u003eAddresses issues of humming or buzzing noises from the compressor during failed start attempts.\u003c\/li\u003e\n\u003cli\u003eA solution for frequent circuit breaker tripping upon system start-up.\u003c\/li\u003e\n\u003cli\u003eCan be installed proactively on aging systems to extend compressor and component life.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all electrical power to the HVAC unit at the breaker and service disconnect before beginning work.\u003c\/li\u003e\n\u003cli\u003eVerify the kit's specifications match your system's voltage and compressor tonnage rating.\u003c\/li\u003e\n\u003cli\u003eMount the device securely inside the control panel, away from excessive moisture and moving parts.\u003c\/li\u003e\n\u003cli\u003eFollow the included wiring diagram precisely to ensure correct connections to the run capacitor and compressor terminals.\u003c\/li\u003e\n\u003cli\u003eConfirm all wire connections are tight and properly insulated before restoring power.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45772994674877,"sku":"AZ72822158","price":33.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00717564_1_de9ea1aa-568c-4a42-9e74-484f1a9942f5.jpg?v=1762245880"},{"product_id":"02537499000-gas-furnace-flame-sensor","title":"025-37499-000 Gas Furnace Flame Sensor - For York Luxaire Coleman Gas Furnace","description":"\u003ch2\u003e025-37499-000 Gas Furnace Flame Sensor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCrucial safety component for gas-fired appliances\u003c\/li\u003e\n\u003cli\u003eDetects burner flame to ensure safe ignition and operation\u003c\/li\u003e\n\u003cli\u003eConstructed from high-quality, corrosion-resistant materials for longevity\u003c\/li\u003e\n\u003cli\u003eDesigned as a direct-fit replacement for the original equipment manufacturer part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e025-37499-000\u003c\/li\u003e\n\u003cli\u003eS1-025-37499-000\u003c\/li\u003e\n\u003cli\u003eS1-02537499000\u003c\/li\u003e\n\u003cli\u003e02537499000\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFits specific furnace models from York, Luxaire, and Coleman\u003c\/li\u003e\n\u003cli\u003eCompatible with various models including the TG9S series\u003c\/li\u003e\n\u003cli\u003eConfirmed fit for models such as ACS90453BXA, ACS90703BXA, and ACS90704CXA\u003c\/li\u003e\n\u003cli\u003ePlease verify fitment by checking your furnace's service manual or original part number\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace burners ignite briefly then shut down after a few seconds\u003c\/li\u003e\n\u003cli\u003eVisible carbon buildup, corrosion, or damage on the sensor rod\u003c\/li\u003e\n\u003cli\u003eDiagnostic fault codes from the furnace control board indicate a flame sensor issue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect electrical power and shut off the gas supply to the furnace before beginning installation\u003c\/li\u003e\n\u003cli\u003eThe sensor is typically located in the path of the burner assembly, opposite the igniter\u003c\/li\u003e\n\u003cli\u003eHandle the new sensor by its ceramic base to avoid transferring skin oils to the metal rod\u003c\/li\u003e\n\u003cli\u003eEnsure the new sensor is securely mounted and the electrical connection is firm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45772996673725,"sku":"AZ19339427","price":10.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00129371_1_fafa2dde-141b-4174-a14d-6941afd83175.jpg?v=1762245829"},{"product_id":"52w29-furnace-flame-sensor","title":"52W29 Furnace Flame Sensor Replacement - For Lennox Armstrong \u0026 Ducane Furnaces","description":"\u003ch2\u003e52W29 Furnace Flame Sensor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitors burner flame to ensure safe furnace operation.\u003c\/li\u003e\n\u003cli\u003eDirect replacement for the original manufacturer's part.\u003c\/li\u003e\n\u003cli\u003eOverall length: 5.25 inches.\u003c\/li\u003e\n\u003cli\u003eSensing rod length: 2.75 inches.\u003c\/li\u003e\n\u003cli\u003eConstructed with a high-temperature resistant metal rod and ceramic insulator.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e52W29\u003c\/li\u003e\n\u003cli\u003e52W2901\u003c\/li\u003e\n\u003cli\u003e31L71\u003c\/li\u003e\n\u003cli\u003e31L7101\u003c\/li\u003e\n\u003cli\u003eLB-74940A\u003c\/li\u003e\n\u003cli\u003e28PV41\u003c\/li\u003e\n\u003cli\u003e903600\u003c\/li\u003e\n\u003cli\u003eFLS52W29\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFits specific gas furnace models from Lennox, Armstrong, and Ducane.\u003c\/li\u003e\n\u003cli\u003eCompatible with furnace series including G40, G41, G50, G51, G60, G61, and G71.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace ignites but shuts down after a few seconds.\u003c\/li\u003e\n\u003cli\u003eFurnace fails to heat consistently or at all.\u003c\/li\u003e\n\u003cli\u003eThe sensor rod is visibly corroded, cracked, or has heavy carbon buildup that cannot be cleaned.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all electrical power to the furnace before servicing.\u003c\/li\u003e\n\u003cli\u003eHandle the component by its metal bracket to avoid damaging the ceramic insulator.\u003c\/li\u003e\n\u003cli\u003eEnsure the sensor rod is properly positioned in the flame path for correct operation.\u003c\/li\u003e\n\u003cli\u003eVerify a secure wire connection before restoring power.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45844230701245,"sku":"AZ1624905","price":7.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ1624905_1_d5459a7d-54cf-4dc4-8390-539d4a043286.jpg?v=1762245777"},{"product_id":"0130f00010-furnace-flame-sensor-2pack","title":"0130F00010 Furnace Flame Sensor Replacement - For Goodman Amana Furnaces - 2 Pack","description":"\u003ch2\u003e0130F00010 Furnace Flame Sensor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDetects flame presence in gas furnaces for safe ignition and operation.\u003c\/li\u003e\n\u003cli\u003eConstructed from high-quality, corrosion-resistant metal and a durable ceramic insulator.\u003c\/li\u003e\n\u003cli\u003eDirect replacement for specified part numbers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e0130F00010\u003c\/li\u003e\n\u003cli\u003eB1172606\u003c\/li\u003e\n\u003cli\u003eB11726-06\u003c\/li\u003e\n\u003cli\u003e20488501\u003c\/li\u003e\n\u003cli\u003eTJFLS013\u003c\/li\u003e\n\u003cli\u003e2645136\u003c\/li\u003e\n\u003cli\u003eAP4513976\u003c\/li\u003e\n\u003cli\u003eAP6326767\u003c\/li\u003e\n\u003cli\u003eL38035\u003c\/li\u003e\n\u003cli\u003eACS90453BXA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for select gas furnace models from brands including:\u003c\/li\u003e\n\u003cli\u003eAmana\u003c\/li\u003e\n\u003cli\u003eDaikin\u003c\/li\u003e\n\u003cli\u003eGoodman\u003c\/li\u003e\n\u003cli\u003eJanitrol\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace shuts down shortly after ignition.\u003c\/li\u003e\n\u003cli\u003eMain burner fails to stay lit.\u003c\/li\u003e\n\u003cli\u003eFrequent or intermittent system cycling.\u003c\/li\u003e\n\u003cli\u003eVisible corrosion, carbon buildup, or damage to the existing sensor rod.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all electrical power to the furnace before servicing.\u003c\/li\u003e\n\u003cli\u003eHandle the new sensor by its ceramic base to avoid transferring oils from your skin to the metal rod.\u003c\/li\u003e\n\u003cli\u003eEnsure the rod is properly positioned to be engulfed by the burner flame for accurate sensing.\u003c\/li\u003e\n\u003cli\u003eConfirm the wire connection is secure after installation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45844232995005,"sku":"AZ00170228","price":7.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00170228_1_f655834a-c0d6-47f3-b021-399cb14124c2.jpg?v=1762245776"},{"product_id":"622286893-furnace-ignitor-hot-surface-igniter","title":"62-22868-93 Furnace Ignitor Hot Surface Igniter","description":"\u003ch2\u003e62-22868-93 Furnace Ignitor Hot Surface Igniter\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect replacement hot surface ignitor\u003c\/li\u003e\n\u003cli\u003eConstructed from high-temperature silicon carbide\u003c\/li\u003e\n\u003cli\u003eVoltage: 120V\u003c\/li\u003e\n\u003cli\u003eWire Lead Length: 5.25 inches\u003c\/li\u003e\n\u003cli\u003eHeat-up Time: Approximately 34 seconds\u003c\/li\u003e\n\u003cli\u003eIncludes two high-temperature ceramic wire nuts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e62-22868-93\u003c\/li\u003e\n\u003cli\u003e62-22868-02\u003c\/li\u003e\n\u003cli\u003e62-22868-931PK\u003c\/li\u003e\n\u003cli\u003e62-22868-93-1PK\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEngineered for use in most Rheem, Ruud, and Weatherking gas furnaces.\u003c\/li\u003e\n\u003cli\u003eDirect fit for models requiring part number 62-22868-93, including the Rheem Criterion furnace series.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace blower runs but burners fail to light.\u003c\/li\u003e\n\u003cli\u003eVisible crack, break, or burn spot on the ignitor element.\u003c\/li\u003e\n\u003cli\u003eIgnitor does not glow at the start of the heating cycle.\u003c\/li\u003e\n\u003cli\u003eIntermittent heating or frequent system lockouts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect electrical power and shut off the gas supply to the furnace before servicing.\u003c\/li\u003e\n\u003cli\u003eHandle the new ignitor by its ceramic base only. Do not touch the silicon carbide element, as skin oils can cause damage and premature failure.\u003c\/li\u003e\n\u003cli\u003eEnsure wire connections are secure using the supplied ceramic wire nuts.\u003c\/li\u003e\n\u003cli\u003eVerify the ignitor is properly aligned within the burner assembly after installation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45844236796093,"sku":"AZ00743408","price":23.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00743408_1_99197a3f-a8ac-458f-aab8-6bbaaec0a749.jpg?v=1762245702"},{"product_id":"20162904-furnace-primary-limit-switch-150f-to-110f","title":"20162904 Furnace Primary Limit Switch (150°F to 110°F) - For Goodman Furnace","description":"\u003ch2\u003e20162904 Furnace Primary Limit Switch\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature Range: Opens at 150°F (65.5°C) and closes at 110°F (43.3°C).\u003c\/li\u003e\n\u003cli\u003eFunction: Monitors plenum temperature and automatically shuts down the furnace if it exceeds the high limit, preventing overheating.\u003c\/li\u003e\n\u003cli\u003eConstruction: Made from aluminum alloy and thermoplastic materials for durability and reliable conductivity.\u003c\/li\u003e\n\u003cli\u003eType: Primary high-limit temperature control switch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e20162904\u003c\/li\u003e\n\u003cli\u003e20162904S\u003c\/li\u003e\n\u003cli\u003eL40-524\u003c\/li\u003e\n\u003cli\u003eL40524\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for use in various Goodman brand furnaces.\u003c\/li\u003e\n\u003cli\u003eVerify the part number in your appliance's service manual to ensure proper fitment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe furnace cycles on and off frequently without reaching the set temperature.\u003c\/li\u003e\n\u003cli\u003eThe indoor blower motor runs continuously.\u003c\/li\u003e\n\u003cli\u003eThe furnace fails to ignite or produce heat.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all electrical power to the furnace before servicing.\u003c\/li\u003e\n\u003cli\u003eConfirm the temperature ratings of the replacement switch match the original part.\u003c\/li\u003e\n\u003cli\u003eNote the position of the electrical connections before removing the old switch.\u003c\/li\u003e\n\u003cli\u003eInstallation by a qualified service technician is recommended.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45844237254845,"sku":"AZ00211289","price":14.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00211289_1_f29a5e05-166e-4352-9ffd-3f3df9f5c493.jpg?v=1762245686"},{"product_id":"87f16-furnace-primary-limit-switch-up-to-140f","title":"87F16 Furnace Primary Limit Switch up to 140°F - For Lennox Furnaces - Replaces 87F16 87F1601 L140-30F 36T01B3","description":"\u003ch2\u003e87F16 Furnace Primary Limit Switch up to 140°F\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrimary high-limit safety control for forced-air furnaces\u003c\/li\u003e\n\u003cli\u003eActivates at a fixed temperature of 140°F (60°C) to prevent overheating\u003c\/li\u003e\n\u003cli\u003eAutomatically resets at 110°F (43°C)\u003c\/li\u003e\n\u003cli\u003eSwitch configuration: SPST (Single Pole, Single Throw), normally open contacts\u003c\/li\u003e\n\u003cli\u003eProbe insertion length: 3 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e87F16\u003c\/li\u003e\n\u003cli\u003e87F1601\u003c\/li\u003e\n\u003cli\u003eL140-30F\u003c\/li\u003e\n\u003cli\u003eL140F-40\u003c\/li\u003e\n\u003cli\u003e36T01B3\u003c\/li\u003e\n\u003cli\u003e42155\u003c\/li\u003e\n\u003cli\u003eA1247\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned as a direct replacement for specific Lennox brand furnaces.\u003c\/li\u003e\n\u003cli\u003eVerify fitment by confirming the part number on your original switch or in your equipment's service manual.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace blower runs continuously after the heating cycle has stopped.\u003c\/li\u003e\n\u003cli\u003eHeating system short-cycles or shuts down prematurely.\u003c\/li\u003e\n\u003cli\u003eFurnace fails to produce heat or ignite the burners.\u003c\/li\u003e\n\u003cli\u003eControl board displays a fault code indicating an open limit switch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all electrical power to the furnace before servicing.\u003c\/li\u003e\n\u003cli\u003eLocate the limit switch, typically mounted on the furnace plenum near the heat exchanger.\u003c\/li\u003e\n\u003cli\u003eNote wire connections before removing the old switch.\u003c\/li\u003e\n\u003cli\u003eInstall the new switch, secure it with the mounting screws, and reconnect the wires to the terminals.\u003c\/li\u003e\n\u003cli\u003eRestore power and test the furnace through a complete heating cycle to ensure proper operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45844237353149,"sku":"AZ00638885","price":20.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00638885_1_0d1a3ffb-8997-4ab8-873f-5f1bd756a87f.jpg?v=1762245684"},{"product_id":"10-uf-mfd-5-370440v-cbb65-oval-run-start-capacitor-1","title":"10 uF MFD ±5% 370\/440 VAC CBB65 CBB65A Oval Run Start Capacitor - Fits AC Unit Fan Motor, Pool Pump, Condenser","description":"\u003ch2\u003e10 uF MFD ±5% 370\/440V CBB65 Oval Run Start Capacitor\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eCapacitance: 10 Microfarad (uF\/MFD)\u003c\/li\u003e\n    \u003cli\u003eTolerance: ±5%\u003c\/li\u003e\n    \u003cli\u003eVoltage Rating: Dual rated for 370V or 440V AC\u003c\/li\u003e\n    \u003cli\u003eFrequency: 50\/60Hz\u003c\/li\u003e\n    \u003cli\u003eModel: CBB65\u003c\/li\u003e\n    \u003cli\u003eShape: Oval\u003c\/li\u003e\n    \u003cli\u003eConstruction: Oil-filled metallized polypropylene film\u003c\/li\u003e\n    \u003cli\u003eSafety: Integrated pressure-sensitive interrupter\u003c\/li\u003e\n    \u003cli\u003eTerminals: Standard 1\/4 inch male terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cp\u003eReplaces any single-value, oval-shaped run capacitor with identical 10 uF capacitance and 370V or 440V specifications. Serves as a direct replacement for CBB65 and CBB65A models with matching ratings.\u003c\/p\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cp\u003eDesigned for continuous duty in a variety of motor-run applications:\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003eAir conditioner condenser fan motors\u003c\/li\u003e\n    \u003cli\u003eHeat pump compressors and fan motors\u003c\/li\u003e\n    \u003cli\u003eFurnace blower motors\u003c\/li\u003e\n    \u003cli\u003ePool and spa pump motors\u003c\/li\u003e\n    \u003cli\u003eOther single-phase AC electric motors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cp\u003eReplacement may be necessary if you observe the following symptoms:\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003eMotor hums but does not start\u003c\/li\u003e\n    \u003cli\u003eFan or motor requires a manual push to start\u003c\/li\u003e\n    \u003cli\u003eAC unit compressor fails to engage\u003c\/li\u003e\n    \u003cli\u003eUnit runs intermittently or blows warm air\u003c\/li\u003e\n    \u003cli\u003eVisible bulging, cracking, or fluid leakage from the capacitor case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eDisconnect all electrical power to the unit before performing any work.\u003c\/li\u003e\n    \u003cli\u003eSafely discharge the existing capacitor by shorting across the terminals with an insulated screwdriver.\u003c\/li\u003e\n    \u003cli\u003eVerify that the uF (MFD) rating matches the original capacitor. The voltage rating can be equal to or higher than the original, but not lower.\u003c\/li\u003e\n    \u003cli\u003eConnect wires to the new terminals. Polarity is not a factor for two-terminal AC capacitors.\u003c\/li\u003e\n    \u003cli\u003eSecure the new capacitor in the original mounting bracket.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45860005019837,"sku":"AZ00248300","price":14.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00248300_1_707570fa-22f2-4171-bf39-52a809932897.jpg?v=1762245629"}],"url":"https:\/\/bluestarspartstrend.com\/collections\/ruud-brand.oembed","provider":"BlueStars Parts","version":"1.0","type":"link"}