{"product_id":"dc4700016a-dryer-thermal-fuse-thermostat-dc3200007a-dryer-thermistor","title":"DC47-00016A Thermal Fuse Thermostat \u0026 DC32-00007A Dryer Thermistor for Samsung \u0026 Kenmore Dryers","description":"\u003ch2\u003eDC47-00016A Thermal Fuse \u0026amp; DC32-00007A Thermistor Dryer Sensor Kit\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Thermal Monitoring:\u003c\/strong\u003e The DC32-00007A thermistor is an NTC (Negative Temperature Coefficient) sensor that communicates real-time temperature data to the control board, ensuring consistent heat levels and preventing fabric damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Limit Safety Cut-Off:\u003c\/strong\u003e The DC47-00016A thermal fuse acts as a critical safety barrier, immediately cutting power to the heating element if temperatures exceed safe operating limits to prevent dryer fires.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRapid Response Engineering:\u003c\/strong\u003e Both sensors are designed with low-latency thermal conductivity, allowing the dryer to react instantly to temperature spikes caused by restricted airflow or lint buildup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture-Resistant Housing:\u003c\/strong\u003e Encased in high-grade, heat-stabilized polymers and corrosion-resistant metals, these components are built to survive the high-humidity, high-vibration environment of a dryer drum housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExact Electrical Calibration:\u003c\/strong\u003e Engineered to match original factory resistance (Ohms) specifications, ensuring the control board receives accurate signals for error-free cycle timing and energy-efficient drying.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Fuse (DC47-00016A):\u003c\/strong\u003e AP4201894, PS4205213, WP35001087, 35001087, 2068545, 1122480, L0016A, EAP4205213, EAP11741821, PD00005341\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermistor (DC32-00007A):\u003c\/strong\u003e AP4201716, PS4204984, 35001191, DE0007A, N3S1-K41, 2068429, AH2038482, EAP2461163, PS2461163, AP6008688\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cp\u003eThis sensor kit is the primary electronic temperature control set for modern Samsung and Kenmore-branded dryers. Key compatible series include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSamsung DV Series:\u003c\/strong\u003e Fits hundreds of models including \u003cstrong\u003eDV45H7000EW\u003c\/strong\u003e, \u003cstrong\u003eDV48H7400EW\u003c\/strong\u003e, \u003cstrong\u003eDV42H5000EW\u003c\/strong\u003e, DV210AEW, DV4006110, and DV50F9A8EVP.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSamsung DVE\/DVG Series:\u003c\/strong\u003e Compatible with both Electric (DVE) and Gas (DVG) versions of the 400, 450, 480, and 500 series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKenmore (402 Series):\u003c\/strong\u003e Fits many 402-prefix models produced by Samsung for Sears (e.g., 402.89032010, 402.99032011).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e These parts are typically located on the \u003cstrong\u003eBlower Housing\u003c\/strong\u003e or the \u003cstrong\u003eHeater Duct\u003c\/strong\u003e. Verify your model number to ensure your unit uses the \"blue-tipped\" thermistor style.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Heat at All:\u003c\/strong\u003e The dryer runs and the drum turns, but the air remains cold. This often happens because the DC47-00016A thermal fuse has blown to protect the unit from an overheat condition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\"tS\", \"tE\", or \"HE\" Error Codes:\u003c\/strong\u003e Samsung dryers will display these error codes on the console when the control board detects an open circuit or incorrect resistance from the thermistor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong Drying Times:\u003c\/strong\u003e If the thermistor is out of calibration, it may signal the heater to turn off too early, leaving clothes damp even after a full cycle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDryer Shuts Off Mid-Cycle:\u003c\/strong\u003e The unit stops unexpectedly a few minutes into the cycle as the sensors detect a rapid, unsafe rise in temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverheating:\u003c\/strong\u003e If the thermistor fails in a \"closed\" state, the heater may stay on too long, making the top of the dryer cabinet hot to the touch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First:\u003c\/strong\u003e You MUST unplug the dryer. This repair requires accessing the internal blower and heater assemblies, which are connected to high-voltage circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess the Sensors:\u003c\/strong\u003e Most technicians access these parts by removing the lower front kickplate or the entire front panel and drum. The thermistor and fuse are usually mounted side-by-side on the blower housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe \"Ohm\" Check:\u003c\/strong\u003e Before installing, you can test the new DC32-00007A thermistor with a multimeter. At room temperature (77°F), it should read approximately \u003cstrong\u003e10,000 Ohms (10kΩ)\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck Airflow First:\u003c\/strong\u003e If your thermal fuse has blown, it is almost always caused by a \u003cstrong\u003eclogged dryer vent\u003c\/strong\u003e. Before running the dryer with new parts, clean your exhaust duct to the outside to prevent the new fuse from blowing immediately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne Screw Mounting:\u003c\/strong\u003e These parts are usually held in by a single 1\/4-inch hex head screw. Be careful not to over-tighten, as the plastic blower housing can strip easily.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45367431037117,"sku":"AZ00125797","price":15.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00125797_1_3c5a5507-829c-4e85-86a8-12b1a272b210.jpg?v=1762246751","url":"https:\/\/bluestarspartstrend.com\/products\/dc4700016a-dryer-thermal-fuse-thermostat-dc3200007a-dryer-thermistor","provider":"BlueStars Parts","version":"1.0","type":"link"}