{"product_id":"dc9600887a-dc4700016a-dc4700018a-dryer-thermal-fuse-and-thermostat-kit","title":"DC96-00887A \u0026 DC47-00016A \u0026 DC47-00018A Dryer Thermal Fuse \u0026 Thermostat Kit for Samsung Kenmore Dryers","description":"\u003ch2\u003eDryer Thermal Fuse and Thermostat Kit (DC96-00887A, DC47-00016A, DC47-00018A)\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete Thermal Protection:\u003c\/strong\u003e This comprehensive 3-piece safety kit includes the primary thermal fuse, thermal cut-off, and thermostat to completely rebuild the temperature regulation system of your electric dryer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Precision Calibration:\u003c\/strong\u003e Each component is manufactured to strict factory standards, ensuring they trip at the exact temperature required to prevent dangerous overheating and potential fire hazards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Construction:\u003c\/strong\u003e Built with premium heat-resistant materials and robust internal contacts designed to handle the continuous high-temperature cycles of heavy laundry loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Drop-In Replacement:\u003c\/strong\u003e Features standard male spade terminals and exact-fit mounting brackets for a seamless, plug-and-play installation without any wire splicing or modifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRestores Heating Performance:\u003c\/strong\u003e Replaces aging sensors that may be \"short-cycling\" your dryer, instantly resolving issues where clothes take too long to dry or remain cold.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplaces \/ Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Fuse (DC96-00887A):\u003c\/strong\u003e AP4207819, PS2038484, DC96-00887C, AP5966894, EAP2038484, 2068546, 1122481, PD00027514, L0887A, ERDC96-00887A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Cut-Off (DC47-00016A):\u003c\/strong\u003e AP4201894, PS4205213, WP35001087, 35001087, 2068545, 1122480, L0016A, EAP4205213, EAP11741821, PD00005341\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat (DC47-00018A):\u003c\/strong\u003e AP4201898, PS4205217, WP35001092, 35001092, 1122485, AP4201899, PS2038383, EAP4205217, PD00002016, DE0018A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cp\u003eThis 3-piece thermal sensor kit is compatible with a wide range of electric dryers. Key compatible brands include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSamsung:\u003c\/strong\u003e Fits hundreds of DV series front-load and top-load matching electric dryers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKenmore \/ Sears:\u003c\/strong\u003e Compatible with select 402-prefix electric dryers manufactured by Samsung.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmana \u0026amp; Maytag:\u003c\/strong\u003e Fits specific cross-compatible models utilizing these standard DC47\/DC96-style thermal sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e Always verify your dryer runs on a standard 240V electrical connection. These thermal sensors are specifically rated for electric dryers and may not be compatible with gas models.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to Replace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Heat Production:\u003c\/strong\u003e The dryer powers on and the drum spins normally, but the internal air remains completely cold throughout the entire cycle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShuts Off Prematurely:\u003c\/strong\u003e The dryer starts but suddenly powers down after only a few minutes, indicating a tripped thermal fuse.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInconsistent Drying:\u003c\/strong\u003e Clothes require multiple cycles to fully dry, suggesting a failing thermostat is cutting power to the heating element too early.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePreventative Maintenance:\u003c\/strong\u003e If you are replacing a burned-out heating element, it is highly recommended to replace these three sensors simultaneously to prevent the new element from failing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First:\u003c\/strong\u003e \u003cstrong\u003eCRITICAL:\u003c\/strong\u003e Electric dryers in the United States operate on a high-voltage 240V circuit. You must completely unplug the machine from the wall outlet before removing the back panel to avoid severe electrical shock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest for Continuity:\u003c\/strong\u003e \u003cstrong\u003ePRO TIP:\u003c\/strong\u003e Before swapping the parts, use a digital multimeter to test each old sensor for continuity. A sensor with no continuity has \"blown\" and is the source of the heat failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument the Wiring:\u003c\/strong\u003e The heating assembly has multiple color-coded wires. Take a clear reference photo with your phone before disconnecting any spade terminals to ensure accurate reassembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClear the Exhaust Vent:\u003c\/strong\u003e A blown thermal fuse is almost always caused by restricted airflow. Thoroughly vacuum the internal dryer cabinet and clean your home's external exhaust duct to prevent the new fuses from blowing immediately upon your first test run.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BlueStarsParts","offers":[{"title":"Default Title","offer_id":45345031225533,"sku":"AZ00150315","price":15.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2576\/7548\/files\/AZ00150315_1_b51aa70a-3f61-4411-8363-d8b0e4301962.jpg?v=1762246907","url":"https:\/\/bluestarspartstrend.com\/products\/dc9600887a-dc4700016a-dc4700018a-dryer-thermal-fuse-and-thermostat-kit","provider":"BlueStars Parts","version":"1.0","type":"link"}