Lifetime Warranty

5300622034 Heating Element Restring Coil for Frigidaire Kenmore Gibson Dryers

Save 13%
0.00 Regular price
$20.40
Regular price $23.46 Sale price
$20.40
In stock
Fast delivery

Secure and trusted checkout with

  • Visa
  • Mastercard
  • American Express
  • PayPal
  • Diners Club
  • Discover
Contact for wholesale

🛠️
CONFIRM THE FIT FOR YOUR MODEL
Enter your model number

5300622034 Dryer Heating Element Restring Coil

Key Features

  • Restring coil for electric dryer heating element assemblies
  • Power Rating: 4600 Watts at 240 Volts
  • Terminal Size: 5/16 inch male spade terminals
  • Constructed from a durable metal alloy for consistent heat generation

Replaces / Cross-Reference Part Numbers

  • AP2135128
  • PS451032
  • AH451032
  • EA451032
  • 131475300
  • 131475320
  • 131475620
  • 131553900
  • 131505700
  • CH22034
  • ER5300622034
  • WE11X99
  • WE14X10015

Compatibility & Fitment

  • Fits various electric dryer models, including those from Frigidaire, Kenmore, and General Electric (GE)
  • Designed for use in specific dryers manufactured from 1996 to the present
  • Confirm your original part number and terminal size before ordering

When to Replace

  • Dryer drum tumbles, but no heat is produced
  • Drying cycles are excessively long
  • Clothes remain damp after a complete cycle
  • Visible breaks or burn spots on the existing heating coil

Installation Tips

  • Disconnect the dryer from the electrical outlet before beginning installation
  • Wear gloves to prevent skin oils from contaminating the new coil, which can cause premature failure
  • Carefully thread the new coil onto the ceramic insulators, ensuring it does not touch the metal housing or overlap itself
  • Ensure all electrical connections are tight and secure
  • Test the new coil for continuity with a multimeter before reassembling the dryer
  • PERFECT FIT

    PERFECT FIT

    BlueStars 5300622034 Dryer Heating Element Restring Coil replaces part numbers: 351, AP2135128, PS451032, AH451032, EA451032.
  • PREMIUM QUALITY

    PREMIUM QUALITY

    5300622034 Dryer Heating Element Restring Coil is made from durable high-quality material and well-tested by the manufacturer.
  • SAVING SOLUTION

    SAVING SOLUTION

    Enjoy the great feeling when your dryer is repaired and works properly like before - BlueStars brings DIY solutions to help you deal with any trouble.
  • SIMPLE INSTALLATION

    SIMPLE INSTALLATION

    The 5300622034 Dryer Heating Element Restring Coil is straightforward to attach, load, and use. Anyone with basic hand tools can install it.
ECONOMICAL DIY REPAIR

ECONOMICAL DIY REPAIR

Enjoy the comfort that our dryer heating element restring coil brings into your dryer - BlueStars provides DIY solutions to help you deal with any troubles
Brand Model Number
Frigidaire AEQ6000ES2, CLCE500FW0, CLCE500FW1, CLCE500FW2, CLCE500FW4, CLCE900FW0, CLCE900FW1, CLCE900FW2, DE271KDW8, DE27A5WAFC, DE27A8WAFC, DE27S8WAGC, DE27T3WAFC, DE350RXD3, DE350RXD4, DE350RXW3, DE350RXW4, DE400ADD3, DE400ADW3, DE500ADD7, DE500ADW7, DE600ADD3, DE600ADW3, DE650ADD3, DE650ADW3, DE800ADD3, DE800ADD4, DE800ADW3, DE800ADW4, DEA500KD3, DEA500KW3, DEA501KD3, DEA501KW3, DET400KD3, DET400KW3, EL27M6WAFB, F31C336CS0, F31C336CS1, F31C336CT0, F31C336CT1, F31C546CS0, F31C546CS1, F31C546CT0, F31C546CT1, F31C747CS0, F31C747CT0, FDE116RBW0, FDE116RBW1, FDE216RBS0, FDE216RBS1, FDE216RBS2, FDE216RBT0, FDE336LBS0, FDE336LBS1, FDE336LBS2, FDE336NBS0, FDE336NBS1, FDE336NBS2, FDE336RBS0, FDE336RBS1, FDE336RBS2, FDE336RBT0, FDE336RBT1, FDE336RBT2, FDE436RBS0, FDE436RBS1, FDE436RBS2, FDE436RBT1, FDE436RBT2, FDE546DBD1, FDE546DBL0, FDE546DBW0, FDE546DBW1, FDE546LBS0, FDE546LBS1, FDE546LBS2, FDE546NBS0, FDE546NBS1, FDE546NBS2, FDE546NBT0, FDE546NBT1, FDE546NBT2, FDE546RBS0, FDE546RBS1, FDE546RBS2, FDE546RBT0, FDE546RBT1, FDE747RBS0, FDE747RBS1, FDE747RBT0, FDE747RBT1, FDE847GCS0, FDE847GCT0, FDE847RBS0, FDE847RBT0, FDE7976FS1, FEQ332ES0, FER231AS2, FEX831CS0, FEX831FS1, FLSE72GCS0, FLSE72GCT0, FLXE52RBS0, FLXE52RBT0, FSE747GC, FSE747GCS0, GLEH1642FS1, GLER642AS0, LE400AXD2, LE400AXW2, LCE702ADD3, LCE702AWD2, LCE702AWW2, LCE702AWW3, LDE333PBW0, LFD301EW1, MDE116RBW1, MDE216RBD0, MDE216RBD1, MDE216RBW1, MDE216RBWD0, MDE216RBWW0, MDE316RBD0, MDE336MBD0, MDE336MBWD0, MDE436RBD0, MDE436RBD1, MDE436RBW1, MDE436RBWW0, MLXE42RBD0, MLXE42RBD1, MLXE42RBW1, MLXE62RBD0, MLXE62RBD1, MLXE62RBW1, MLXE62RBWW0, WDE336RBS0, WDE336RBS2, WDE546RBD0, WDE546RBD1, WDE546RBS0, WDE546RBW0, WDE546RBW1, WDE646RBSD0, WDE646RBSW0, WDE847PBS0, WDE846RBD0, WDE846RBW0
Gibson DE27A8WAFC, DE27S8WAGC, GDE336RBD1, GDE336RBS0, GDE336RBW0, GDE336RBW1, GDE436RBD1, GDE436RBD2, GDE436RBW0, GDE436RBW1, GDE436RBW2, GDE546RBD1, GDE546RBS0, GDE546RBS1, GDE546RBW0, GDE546RBW1, MDE336MBWW0, MDE436RBWD0
Kelvinator MDE336MBD1, MDE336MBW1, MLXE42RBWD0, MLXE62RBWD0
Kenmore 41784052500, 41799370120, 41799370130, 41799370820, 41799570100, 41799570800
Tappan MDE216RBW0, MDE336MBW0, MDE436RBW0, MLXE42RBW0, MLXE62RBW0, TDE336RBD0, TDE336RBD1, TDE336RBW0, TDE336RBW1, TDE546RBD0, TDE546RBD1, TDE546RBW0, TDE546RBW1
Brand Name
‎BlueStars
Model Info
‎5300622034 AP2135128 PS451032 351
Part Number
‎5300622034
Form Factor
‎Built-in
Burner Type
‎Open
Color
‎As Pictured
Control Console
‎Knobs
Fuel type
‎Electric
Material Type
‎Metal
Included Components
‎5300622034 Dryer Heating Element Restring Coil

FAQ

This coil is compatible with a wide range of dryers manufactured by Frigidaire, Kenmore, Gibson, Tappan, White-Westinghouse, and GE. It fits numerous models, including but not limited to FDE436RBS2, WDE846RBW0, AEQ6000, FEX831C, DBL333EB1, and DSXH43E.
This component replaces OEM part numbers 5300622034, 131475320, 131505700, 131553900, 131475300, 131475400, and 131234600. It also cross-references with AP2135128, AH451032, EA451032, PS451032, 351, PD00000199, and WE14X10015.
The most common sign is that the dryer runs but fails to produce heat, resulting in damp clothes at the end of a cycle. If you notice the dryer takes significantly longer than usual to dry a load, or if the clothes are only slightly warm, the element may be failing. You can verify this by using a multimeter to check for continuity across the element terminals; if there is no continuity, the coil is broken.
The most frequent cause of premature failure is restricted airflow. If your dryer vent hose, lint trap, or the internal exhaust ducts are clogged with lint, the dryer cannot dissipate heat properly. This causes the element to cycle on and off rapidly or overheat, eventually leading to a broken coil.
Before installing the new coil, it is critical to thoroughly clean your dryer's vent ducting and external exhaust hose. If the airflow restriction is not cleared, the new element will likely overheat and fail shortly after installation. Additionally, inspect your thermal fuse and high-limit thermostat for continuity, as these components often trip or fail when the heating element malfunctions.
Replacing the coil is a manageable task for most DIYers, typically taking 30 to 60 minutes. You will generally need a screwdriver (Phillips or flathead) and a nut driver to remove the dryer's back or side panel. Be sure to disconnect the power supply before starting. Take a photo of the wire connections before removing the old element to ensure you reattach them correctly to the new coil.