Key Features

  • Critical Fire Prevention: Engineered as a non-resettable safety device that immediately cuts power to the dryer’s heating circuit or motor if internal temperatures exceed safe operating limits (trips at approximately 196°F / 91°C).
  • Precision Thermal Calibration: Manufactured with a high-sensitivity internal solder link designed to react instantly to localized overheating, protecting your home from potential dryer fires caused by restricted airflow.
  • High-Conductivity Terminals: Features two 1/4-inch male spade terminals coated in a corrosion-resistant alloy, ensuring a low-resistance electrical connection and preventing terminal melting.
  • Universal Whirlpool Design: The standardized 2-inch white plastic housing fits perfectly into the blower wheel housing mounting slots of virtually all Whirlpool-manufactured dryers produced over the last 30 years.
  • Essential 3-Piece Value Pack: Provides multiple replacement fuses, allowing you to restore operation immediately and keep spares on hand—a necessity since this part is designed to fail to protect the machine.

Replaces / Cross-Reference Part Numbers

  • 3392519
  • WP3392519
  • WP3392519VP
  • 3388651
  • 694511
  • 80005
  • AP6008325
  • PS11741460
  • EAP11741460
  • ET401

Compatibility & Fitment

This thermal fuse is the most common safety component for the entire line of Whirlpool-manufactured laundry appliances. Key compatible brands include:

  • Whirlpool & Maytag: Fits thousands of LER, LGR, MED, and MGD series models (e.g., LER4634EQ2, MEDC215EW1).
  • Kenmore (110 Series): Compatible with virtually all 110-prefix models produced by Whirlpool for Sears (e.g., 110.60852990).
  • KitchenAid & Amana: Fits various KEDS and NED series units.
  • Roper, Estate, & Crosley: Direct fit for dozens of budget-friendly top-lint-filter dryers.
  • Note: This fuse is typically located on the Blower Wheel Housing. On electric dryers, a blown fuse usually prevents the motor from starting; on gas dryers, the motor may run, but the igniter will not glow.

When to Replace

  • Dryer Won't Start (Electric): You press the start button and hear nothing. If the door switch is good, the thermal fuse has likely blown, breaking the circuit to the motor.
  • No Heat (Gas): The dryer drum turns and the air blows, but the air never gets warm. In gas models, this fuse often sits in the burner circuit.
  • Dryer Shuts Off Mid-Cycle: The unit was running fine but suddenly stopped and will not restart, indicating a thermal spike was detected.
  • Restricted Airflow Warning: If your dryer's "Check Vent" light was on before the unit stopped working, the fuse likely blew due to back-pressure heat.
  • Test with Multimeter: To confirm, set a multimeter to "Continuity." If the fuse shows "Open" (no beep), it is blown and must be replaced.

Installation Tips

  • Safety First: You MUST unplug the dryer. This part is connected to the main power lead; working on it while plugged in is extremely dangerous.
  • Access the Fuse: On most Whirlpool dryers, you must remove the rear panel to reach the blower housing. On some newer models, you may need to remove the front bottom panel.
  • Check Your Venting: IMPORTANT: A thermal fuse almost never fails on its own. It blows because your dryer vent is clogged with lint. Before installing the new fuse, use a vacuum to clean the internal blower and the exhaust duct all the way to the outside wall.
  • Terminal Transfer: Pull the two wires off the old fuse and push them onto the new 3392519. It does not matter which wire goes to which terminal (non-polarized).
  • Don't Over-Tighten: The fuse is held by one 1/4-inch screw. Tighten it until snug, but be careful not to strip the thin metal of the blower housing.
  • WIDE COMPATIBILITY

    WIDE COMPATIBILITY

    Our Thermal Fuse fits Whirlpool, Kenmore, Maytag Washers and more
  • NON-CRACKING DESIGN

    NON-CRACKING DESIGN

    This Thermal Fuse is made of sturdy ABS platsic which is strong and wear-resistant, enhancing durability
  • BEST SOLUTION

    BEST SOLUTION

    BlueStars brings DIY solutions to help you deal with any trouble
  • SIMPLE INSTALLATION

    SIMPLE INSTALLATION

    Just 5 minutes of replacing to make your Dryer run like new!
Rated Temperature
‎196°F (91°C)
Reset Type
‎Non-resettable (one-time / single-blow fuse)
Terminals
‎2 x 3/16" spade terminals
Material
‎Metal / Plastic
Color
‎White / Black / Brass
Overall Dimensions
‎3/4" L x 9/16" W x 2" H
Mounting
‎Attaches to blower wheel housing

FAQ

This thermal fuse is compatible with a wide range of dryers manufactured by Whirlpool, Kenmore, Maytag, KitchenAid, and Roper. It is designed to fit most standard electric dryers from these brands that utilize a 3392519-style fuse.
This part serves as a direct replacement for OEM part number 3392519. It also cross-references with AP6008325, 3388651, 694511, 80005, WP3392519VP, ET401, PS11741460, G4AP0500, and 2986.
The most common symptom is a dryer that runs but fails to produce heat. If your dryer has stopped completely and will not start at all, or if it runs for a few minutes and then shuts off unexpectedly, the thermal fuse has likely blown as a safety precaution.
A thermal fuse is a safety device designed to blow if the dryer overheats. Before installing the new fuse, it is critical to clean your dryer's vent system and exhaust ducting. A restricted or clogged vent is the most common cause of premature fuse failure because it prevents proper airflow, causing the internal temperature to spike.
Replacing the fuse is a straightforward task that typically takes 15 to 30 minutes. You will generally need a 1/4-inch nut driver or screwdriver to remove the dryer's back or front panel, depending on your specific model. Always ensure the dryer is unplugged from the power source before beginning the repair.